Inner diameters of the normal carotid arteries measured using three-dimensional digital subtraction catheter angiography: a retrospective analysis

被引:3
|
作者
Tan, Qingjing [1 ]
Qin, Chao [2 ]
Yang, Junwei [1 ]
Wang, Tianbao [1 ]
Lin, Haohai [1 ]
Lin, Cuiting [2 ]
Chen, Xiangren [2 ]
机构
[1] Guangxi Univ Chinese Med, Dept Neurol, Affiliated Hosp 1, Nanning, Guangxi, Peoples R China
[2] Guangxi Med Univ, Dept Neurol, Affiliated Hosp 1, Nanning, Guangxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Carotid arteries; Carotid bifurcation; Internal diameter; Digital subtraction angiography; Essen Stroke Risk Score; STROKE RISK SCORE; MAGNETIC-RESONANCE ANGIOGRAPHY; STENOSIS; ENDARTERECTOMY; VALIDATION; SURGERY; PLAQUE; REPRODUCIBILITY; BIFURCATION; PREVALENCE;
D O I
10.1186/s12883-021-02328-z
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose To obtain normal ranges for the inner diameters of the carotid arteries. Methods This retrospective analysis included consecutive patients with disease-free carotid arteries who had undergone 3D-DSA at two hospitals in Nanning, Guangxi, between March 2013 and March 2018. Demographic and clinical characteristics, including Essen Stroke Risk Score (ESRS), were extracted from the medical records. The 3D-DSA data were used to calculate the inner diameters of the carotid arteries. Results The analysis included 1182 patients (837 males) aged 58.81 +/- 11.02 years. The inner diameters of the proximal carotid sinus (CS), CS bulge, distal CS, and common carotid artery (CCA) were larger on the right than on the left (P < 0.05). The inner diameters of the proximal CS, CS bulge, distal CS, and CCA on both sides were larger for males than females (P < 0.05). The inner diameters of the proximal CS, CS bulge, and distal CS on both sides were smaller for patients aged > 65 years than for patients aged <= 55 years (P < 0.05). Right CCA inner diameter did not vary with age, whereas left CCA inner diameter was larger for patients aged > 55 years than for patients aged <= 45 years (P < 0.05). The inner diameters of the proximal CS, CS bulge, and distal CS on both sides were smaller for patients with ESRS >= 3 than those with ESRS < 3 (P < 0.05). Conclusion This study provides reference values for the internal diameters of normal carotid arteries. Carotid artery diameters varied with side, sex, and age.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Three-dimensional reconstructed rotational digital subtraction angiography in planning treatment of intracranial aneurysms
    Missler, U
    Hundt, C
    Wiesmann, M
    Mayer, T
    Brückmann, H
    EUROPEAN RADIOLOGY, 2000, 10 (04) : 564 - 568
  • [33] The characteristics of the anterior communicating artery aneurysm complex by three-dimensional digital subtraction angiography
    Sadatomo, T
    Yuki, K
    Migita, K
    Taniguchi, E
    Kodama, Y
    Kurisu, K
    NEUROSURGICAL REVIEW, 2006, 29 (03) : 201 - 207
  • [34] Three-dimensional digital subtraction angiography vs two-dimensional digital subtraction angiography for detection of ruptured intracranial aneurysms:: a study of 86 aneurysms -: Invited comments
    Tomandl, BF
    NEUROLOGY INDIA, 2005, 53 (03) : 290 - 290
  • [35] Quantification of three-dimensional computed tomography angiography for evaluating coronary luminal stenosis using digital subtraction angiography as the standard of reference
    Wei Guo
    Xin Liu
    Zhifan Gao
    Sandeep Pirbhulal
    Wenhua Huang
    Wan-Hua Lin
    Heye Zhang
    Ning Tan
    Yuan-Ting Zhang
    BioMedical Engineering OnLine, 14
  • [36] Quantification of three-dimensional computed tomography angiography for evaluating coronary luminal stenosis using digital subtraction angiography as the standard of reference
    Guo, Wei
    Liu, Xin
    Gao, Zhifan
    Pirbhulal, Sandeep
    Huang, Wenhua
    Lin, Wan-Hua
    Zhang, Heye
    Tan, Ning
    Zhang, Yuan-Ting
    BIOMEDICAL ENGINEERING ONLINE, 2015, 14
  • [37] Multidirectional depiction of internal carotid arterial stenosis:: Three-dimensional time-of-might MR angiography versus rotational and conventional digital subtraction angiography
    Elgersma, OEH
    Wüst, AFJ
    Buijs, PC
    van der Graaf, Y
    Eikelboom, BC
    Mali, WPTM
    RADIOLOGY, 2000, 216 (02) : 511 - 516
  • [38] Fusion Technique Using Three-Dimensional Digital Subtraction Angiography in the Evaluation of Complex Cerebral and Spinal Vascular Malformations
    Fukuda, Kenji
    Higashi, Toshio
    Okawa, Masakazu
    Iwaasa, Mitsutoshi
    Abe, Hiroshi
    Inoue, Tooru
    WORLD NEUROSURGERY, 2016, 85 : 353 - 358
  • [39] Coronary arteries three-dimensional quantification using intravascular ultrasound and angiography
    Leor, OR
    Mauri, J
    Fernandez-Nofrerias, E
    Ayerbe, JL
    Gomez Perez, M
    Tudela, VV
    Rotger, D
    Radeva, P
    EUROPEAN HEART JOURNAL, 2003, 24 : 605 - 605
  • [40] Strain field measurements on mouse carotid arteries using microscopic three-dimensional digital image correlation
    Sutton, M. A.
    Ke, X.
    Lessner, S. M.
    Goldbach, M.
    Yost, M.
    Zhao, F.
    Schreier, H. W.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2008, 84A (01) : 178 - 190