Abdominal MR Imaging at 3.0 T

被引:69
|
作者
Akisik, Fatih M. [1 ]
Sandrasegaran, Kumaresan [1 ]
Aisen, Alex M. [1 ]
Lin, Chen [1 ]
Lall, Chandana [1 ]
机构
[1] Indiana Univ, Sch Med, Dept Radiol, Indianapolis, IN 46202 USA
关键词
D O I
10.1148/rg.275075023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance ( MR) imaging at 3.0 T offers an improved signal-to-noise ratio compared with that at 1.5 T. However, the physics of high field strength also brings disadvantages, such as increases in the specific absorption rate, in magnetic field inhomogeneity effects, and in susceptibility artifacts. The use of 3.0-T MR imaging for abdominal evaluations, in particular, has lagged behind that for other applications because of the difficulty of imaging a large volume while compensating for respiratory motion. At a minimum, abdominal MR imaging at 3.0 T requires modifications in the pulse sequences used at 1.5 T. Such modifications may include a decrease in the flip angle used for refocusing pulses and an increase in the repetition time for T1-weighted acquisitions. In addition, parallel imaging and other techniques ( hyperecho sequences, transition between pseudo steady states) may be used to maintain a high signal-to-noise ratio while decreasing acquisition time and minimizing the occurrence of artifacts on abdominal MR images. (c) RSNA, 2007
引用
收藏
页码:1433 / 1444
页数:12
相关论文
共 50 条
  • [1] 3.0 T MR imaging
    Scarabino, T
    Nemore, F
    Giannatempo, GM
    Popolizio, T
    Stranieri, A
    Salvolini, U
    RIVISTA DI NEURORADIOLOGIA, 2004, 17 (06): : 765 - 776
  • [2] 3.0 T perfusion MR imaging
    Scarabino, T
    Giannatempo, GM
    Pollice, S
    Carriero, A
    Di Costanzo, A
    Tedeschi, G
    Polonara, G
    Salvolini, U
    RIVISTA DI NEURORADIOLOGIA, 2004, 17 (06): : 807 - 812
  • [3] 3.0 T diffusion MR imaging
    Scarabino, T
    Nemore, E
    Esposito, E
    Di Salle, F
    Pollice, S
    Carriero, A
    Agati, R
    Salvolini, U
    RIVISTA DI NEURORADIOLOGIA, 2004, 17 (06): : 795 - 806
  • [4] Body and cardiovascular MR Imaging at 3.0 T
    Lee, Vivian S.
    Hecht, Elizabeth M.
    Taouli, Bachir
    Chen, Qun
    Prince, Keynna
    Oesingmann, Niels
    RADIOLOGY, 2007, 244 (03) : 692 - 705
  • [5] Abdominal applications of 3.0-T MR imaging: Comparative review versus a 1.5-T system
    Choi, Jin-Young
    Kim, Myeong-Jin
    Chung, Yong Eun
    Kim, Ki Youn
    Jones, Alun C.
    de Becker, Jan
    van Cauteren, Marc
    RADIOGRAPHICS, 2008, 28 (04) : e30
  • [6] MR imaging relaxation times of abdominal and pelvic tissues measured in vivo at 3.0 T: Preliminary results
    de Bazelaire, CMJ
    Duhamel, GD
    Rofsky, NM
    Alsop, DC
    RADIOLOGY, 2004, 230 (03) : 652 - 659
  • [7] 3.0-T MR Imaging of Wrist Ligament
    Magee, T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [8] Comparison of 3.0 T versus 1.5 T MR: Imaging of the spine
    Phalke, Vaishali V.
    Gujar, Sachin
    Quint, Douglas J.
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2006, 16 (02) : 241 - +
  • [9] 3.0-T MR Imaging of the Abdomen: Comparison with 1.5 T
    Chang, Kevin J.
    Kamel, Ihab R.
    Macura, Katarzyna J.
    Bluemke, David A.
    RADIOGRAPHICS, 2008, 28 (07) : 1983 - 1998
  • [10] Body MR Imaging at 3.0 T: Understanding the opportunities and challenges
    Barth, Mara M.
    Smith, Martin P.
    Pedrosa, Ivan
    Lenkinski, Robert E.
    Rofsky, Neil M.
    RADIOGRAPHICS, 2007, 27 (05) : 1445 - 1462