MOSFET Assessment of Radiation Dose Delivered to Mice Using the Small Animal Radiation Research Platform (SARRP)

被引:9
|
作者
Ngwa, Wilfred
Korideck, Houari
Chin, Lee M.
Makrigiorgos, G. Mike
Berbeco, Ross I. [1 ]
机构
[1] Brigham & Womens Hosp, Dept Radiat Oncol, Div Med Phys & Biophys, Dana Farber Canc Inst, Boston, MA 02115 USA
关键词
HIGH-RESOLUTION; DOSIMETRY; RADIOTHERAPY; IRRADIATION; DETECTORS; GUIDANCE; BUILDUP; SYSTEM;
D O I
10.1667/RR2536.1
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Ngwa, W., Korideck, H., Chin, L. M., Makrigiorgos, G. M. and Berbeco, R. I. MOSFET Assessment of Radiation Dose Delivered to Mice Using the Small Animal Radiation Research Platform (SARRP). Radiat. Res. 176, 816-820 (2011). The Small Animal Radiation Research Platform (SARRP) is a novel isocentric irradiation system that enables state-of-the-art image-guided radiotherapy research to be performed with animal models. This paper reports the results obtained from investigations assessing the radiation dose delivered by the SARRP to different anatomical target volumes in mice. Surgically implanted metal oxide semiconductor field effect transistors (MOSFET) dosimeters were employed for the dose assessment. The results reveal differences between the calculated and measured dose of -3.5 to 0.5%, -5.2 to -0.7%, -3.9 to 0.5%, -5.9 to 2.5%, -5.5 to 0.5%, and -4.3 to 0% for the left kidney, liver, pancreas, prostate, left lung, and brain, respectively. Overall, the findings show less than 6% difference between the delivered and calculated dose, without tissue heterogeneity corrections. These results provide a useful assessment of the need for tissue heterogeneity corrections in SARRP dose calculations for clinically relevant tumor model sites. (C) 2011 by Radiation Research Society
引用
收藏
页码:816 / 820
页数:5
相关论文
共 50 条
  • [31] Commissioning and radiobiological verification of the small animal radiotherapy research platform (SARRP)
    Kane, Jonathan L.
    CANCER RESEARCH, 2018, 78 (13)
  • [32] PET-BASED DOSE PAINTING RADIATION THERAPY STRATEGY IN A GLIOBLASTOMA RAT MODEL USING THE SMALL ANIMAL RADIATION RESEARCH PLATFORM
    Donche, S.
    Verhoeven, J.
    Bouckaert, C.
    Descamps, B.
    Raedt, R.
    Vanhove, C.
    Goethals, I.
    NEURO-ONCOLOGY, 2021, 23 : 37 - 37
  • [33] An Integrated Method for Reproducible, Accurate Image-guided Stereotactic Cranial Irradiation of Brain Tumors Using the Small Animal Radiation Research Platform (SARRP)
    Baumann, B.
    Kao, G. D.
    Benci, J. L.
    Santoiemma, P. P.
    Chandrasekaran, S.
    Dorsey, J. F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S180 - S180
  • [34] Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
    Donche, Sam
    Verhoeven, Jeroen
    Descamps, Benedicte
    Bouckaert, Charlotte
    Raedt, Robrecht
    Vanhove, Christian
    Goethals, Ingeborg
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2022, (181):
  • [35] Calibration of the Treatment Beam of the Small Animal Radiation Research Platform
    Matinfar, Mohammad
    Iordachita, Iulian
    Ford, Eric
    Wong, John
    Kazanzides, Peter
    2008 IEEE INTERNATIONAL CONFERENCE ON AUTOMATION SCIENCE AND ENGINEERING, VOLS 1 AND 2, 2008, : 609 - +
  • [36] Dosimetric Verification and Commissioning for A Small Animal Radiation Research Platform
    Wang, Y.
    Lin, S.
    Na, Y.
    Black, P.
    Wu, C.
    Cheng, S.
    Connolly, E.
    Wuu, C.
    MEDICAL PHYSICS, 2017, 44 (06) : 2977 - 2977
  • [37] Animal model for precise abdominal irradiation to study radiation-induced gastrointestinal injury using the small animal radiation research platform
    Brodin, P.
    Velcich, A.
    Guha, C.
    Tome, W.
    EUROPEAN JOURNAL OF CANCER, 2015, 51 : S125 - S125
  • [38] Small animal radiation research platform: Imaging, mechanics, control and calibration
    Matinfar, Mohammad
    Gray, Owen
    Iordachita, Iulian
    Kennedy, Chris
    Ford, Eric
    Wong, John
    Taylor, Russell H.
    Kazanzides, Peter
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION- MICCAI 2007, PT 2, PROCEEDINGS, 2007, 4792 : 926 - +
  • [39] Comprehensive Quality Assurance Phantom for the Small Animal Radiation Research Platform
    Jermoumi, M.
    Korideck, H.
    Zygmanski, P.
    Berbeco, R.
    Makrigiorgos, G.
    Cormack, R.
    Ngwa, W.
    MEDICAL PHYSICS, 2014, 41 (06) : 242 - 242
  • [40] Optimization of a Microbeam Collimator for Use on the Small Animal Radiation Research Platform
    Esplen, N.
    Johnstone, C.
    Chergui, L.
    Bazalova-Carter, M.
    MEDICAL PHYSICS, 2018, 45 (06) : E533 - E533