Hamiltonian Control Stabilization for Grid-Side Converters in Doubly-Fed Wind Turbines

被引:0
|
作者
Wang, Cui [1 ]
Zhou, Jun [1 ]
机构
[1] Hohai Univ, Dept Automat Control Engn, Sch Energy & Elect Engn, Nanjing 211100, Jiangsu, Peoples R China
关键词
doubly-fed wind turbine; Hamiltonian energy theory; stabilization;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Based on the Hamiltonian energy theory, the nonlinear models for a class of grid-side converters are transformed into the Hamiltonian models and then the grid-side converter stabilization control laws for doubly-fed wind turbines are contrived such that the closed-loop systems can achieve stability, besides other power improvements. The suggested control method makes it possible to reduce the closed-loop system fluctuations and obtain quicker recovery from voltage dropping, while the direct-current (DC) bus voltage is stabilized swiftly. The Hamiltonian energy approach provides us with a simpler implementation procedure of the controller design, and the resulted controllers have stronger robustness performance. Numerical illustrations show that the proposed Hamiltonian method is effective and satisfactory.
引用
收藏
页码:1252 / 1257
页数:6
相关论文
共 50 条
  • [31] Wind generator stabilization with Doubly-fed ASynchronous Machine
    Wu, Li
    Wang, Zhixin
    IPEMC 2006: CES/IEEE 5TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2006, : 520 - +
  • [32] Grid disturbance response of wind turbines equipped with induction generator and doubly-fed induction generator
    Thiringer, T
    Petersson, A
    Petru, T
    2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 1542 - 1547
  • [33] Wind turbines with doubly-fed induction generator systems with improved performance due to grid requirements
    Ehlert, D.
    Wrede, H.
    2007 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-10, 2007, : 3841 - 3847
  • [34] Wind generator stabilization with doubly-fed asynchronous machine
    Wu, Li
    Wang, Zhi-Xin
    Journal of Shanghai Jiaotong University (Science), 2007, 12 E (02) : 271 - 282
  • [35] CHARACTERISTICS OF A DOUBLY-FED ASYNCHRONOUS GENERATOR APPLIED IN WIND TURBINES
    Milkic, Zarko
    Cukaric, Aleksandar
    Statkic, Sasa
    Maksimovic, Goran
    EKONOMIKA POLJOPRIVREDA-ECONOMICS OF AGRICULTURE, 2018, 65 (01): : 229 - 241
  • [36] LVRT transient compensation strategy for doubly-fed wind turbines under asymmetrical grid faults
    Yang, Shuying, 1600, Automation of Electric Power Systems Press (38):
  • [37] Analysis of Bearing Currents in Doubly-Fed Induction Wind Turbines
    Liu R.
    Ren X.
    Chen J.
    Liu, Ruifang (rfliu@bjtu.edu.cn), 2018, China Machine Press (33): : 4517 - 4525
  • [38] Application of PLL in the Generator-side Converters for Doubly-Fed Wind Power Generation Systems
    Liu You-wei
    Chen Zhi-hui
    Shen Juan
    2012 INTERNATIONAL CONFERENCE ON FUTURE ENERGY, ENVIRONMENT, AND MATERIALS, PT C, 2012, 16 : 1822 - 1830
  • [39] Coordinated control of a doubly fed induction generator wind turbine with series grid-side converter under unbalanced grid voltage conditions
    Yao, Jun
    Liao, Yong
    Li, Hui
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2010, 14 (12): : 1 - 8
  • [40] A control strategy for doubly-fed induction generator wind turbines under asymmetrical grid voltage conditions caused by faults
    Wang, Hongsheng
    Zhang, Wei
    Hu, Jiabing
    He, Yikang
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (04): : 97 - 102