Hamiltonian Control Stabilization for Grid-Side Converters in Doubly-Fed Wind Turbines

被引:0
|
作者
Wang, Cui [1 ]
Zhou, Jun [1 ]
机构
[1] Hohai Univ, Dept Automat Control Engn, Sch Energy & Elect Engn, Nanjing 211100, Jiangsu, Peoples R China
关键词
doubly-fed wind turbine; Hamiltonian energy theory; stabilization;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Based on the Hamiltonian energy theory, the nonlinear models for a class of grid-side converters are transformed into the Hamiltonian models and then the grid-side converter stabilization control laws for doubly-fed wind turbines are contrived such that the closed-loop systems can achieve stability, besides other power improvements. The suggested control method makes it possible to reduce the closed-loop system fluctuations and obtain quicker recovery from voltage dropping, while the direct-current (DC) bus voltage is stabilized swiftly. The Hamiltonian energy approach provides us with a simpler implementation procedure of the controller design, and the resulted controllers have stronger robustness performance. Numerical illustrations show that the proposed Hamiltonian method is effective and satisfactory.
引用
收藏
页码:1252 / 1257
页数:6
相关论文
共 50 条
  • [21] Research on optimization strategy of grid frequency modulation based on doubly-fed wind turbines
    Wang, Chao
    Xu, Jianyuan
    Wang, Liang
    Song, Dan
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2021, 16 (01) : 229 - 239
  • [22] Modelling and Impedance Characterisation of Doubly-fed Wind Turbines
    Yuan, Chenxinwei
    Wang, Peng
    Zhao, Haoran
    Guo, Jingmei
    2024 6TH ASIA ENERGY AND ELECTRICAL ENGINEERING SYMPOSIUM, AEEES 2024, 2024, : 669 - 675
  • [23] Doubly-fed induction generator torque in wind turbines
    Smajo, Jurica
    Vukadinovic, Dinko
    PROCEEDINGS OF THE 3RD IASME/WSEAS INTERNATIONAL CONFERENCE ON ENERGY & ENVIRONMENT: ENERGY AND ENVIRONMENT III, 2008, : 451 - +
  • [24] Power flow optimisation and grid integration of wind turbines with the doubly-fed induction generator
    Rabelo, B
    Hofmann, W
    2005 IEEE 36th Power Electronic Specialists Conference (PESC), Vols 1-3, 2005, : 2930 - 2936
  • [25] Study on High Performance Control of the Machine-Side Converter of Doubly-Fed Turbines under Grid Distortion
    Qi, Huanruo
    Zheng, Ningkang
    Yan, Xiangyang
    Kang, Yilong
    2020 INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND BIOENGINEERING (ICEEB 2020), 2020, 185
  • [26] Minimum Copper Loss Control of Doubly-Fed Induction Generator for Wind Turbines
    Lee, Kahyun
    Ha, Jung-Ik
    2014 IEEE SYMPOSIUM POWER ELECTRONICS AND MACHINES FOR WIND AND WATER APPLICATIONS (PEMWA), 2014,
  • [27] Sensorless MRAS Control of Brushless Doubly-Fed Reluctance Generators for Wind Turbines
    Kashkooli, M. R. Agha
    Jovanovic, Milutin G.
    2020 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), VOL 1, 2020, : 2202 - 2208
  • [28] Composite frequency control strategy of doubly-fed induction generator wind turbines
    Zhu, X.-R., 1600, Power System Protection and Control Press (40):
  • [29] A Synchronization Control Technique for Soft Connection of Doubly-fed Induction Generator based Wind Turbines to the Power Grid
    Muttaqi, K. M.
    Hagh, M. T.
    2017 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2017,
  • [30] Wind Generator Stabilization with Doubly-Fed Asynchronous Machine
    武黎
    王志新
    Journal of Shanghai Jiaotong University, 2007, (02) : 271 - 282