Low dose fraction behavior of high sensitivity radiochromic film

被引:9
|
作者
Hirata, EY [1 ]
Cunningham, C [1 ]
Micka, JA [1 ]
Keller, H [1 ]
Kissick, MW [1 ]
Dewerd, LA [1 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
关键词
radiochromic; GafChromic HS film; potical density; film dosimetry;
D O I
10.1118/1.1883565
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A high sensitivity (HS) model of radiochromic film is receiving increasing use. The film's linear sensitometric response in the range of 0.5-40 Gy would make this film an ideal candidate for complex dosimetry applications that require tissue equivalence. This study investigates the potential use for clinical dosimetry of typical radiotherapy fractions at relatively low doses (0.5-5 Gy). The experiment involved exposing 25 pre-exposed pieces of HS film to five equal fractions of doses from 0.5 to 5 Gy 24 hours apart. The cumulative dose for each film was carefully monitored and optical density measurements were used as the sole determination of film response to dose. The average behavior of the various fractionation schemes was roughly consistent with previous observations of the MD-55 radiochromic film with about twice the overall sensitivity as expected. However, at low doses and low dose increments, unexpected variations beyond a well-documented low dose nonlinearity were observed. These unexpected variations may indicate complex polymer kinetics at low doses. This type of film would require extra care beyond that described in TG-55 for accurate use at low doses or low dose fraction schemes. (c) 2005 American Association of Physicists in Medicine.
引用
收藏
页码:1054 / 1060
页数:7
相关论文
共 50 条
  • [21] A radiochromic film based on leucomalachite green for high-dose dosimetry applications
    Soliman, Y. S.
    Basfar, A. A.
    Msalam, R. I.
    RADIATION MEASUREMENTS, 2014, 62 : 45 - 51
  • [22] Dose measurements nearby low energy electronic brachytherapy sources using radiochromic film
    Devic, Slobodan
    Liang, LiHeng
    Tomic, Nada
    Bekerat, Hamed
    Morcos, Marc
    Popovic, Marija
    Watson, Peter
    Aldelaijan, Saad
    Seuntjens, Jan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 40 - 44
  • [23] Sensitivity of document scanners used for radiochromic film dosimetry
    Wang, Y.
    Lewis, D.
    Poon, E.
    Verhaegen, F.
    Podgorsak, E.
    Devic, S.
    MEDICAL PHYSICS, 2006, 33 (06) : 2135 - 2135
  • [24] Intercomparison of EDR2 and high sensitivity radiochromic film for measuring small beams
    Zeidan, O
    Li, J
    Low, D
    Dempsey, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1397 - 1397
  • [25] Toward Absolute Dose Measuments Using Radiochromic Film
    Girard, F.
    Bouchard, H.
    Lacroix, F.
    MEDICAL PHYSICS, 2011, 38 (06) : 3507 - U124
  • [26] Radiochromic film as a radiotherapy surface-dose detector
    Butson, MJ
    Mathur, JN
    Metcalfe, PE
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (06): : 1073 - 1078
  • [27] Off-axis dose measurement using new high sensitivity radiochromic film: Potential application to pacemaker dosimetry in a clinical setting
    Chiu-Tsao, S.
    Chan, M.
    MEDICAL PHYSICS, 2007, 34 (06) : 2475 - 2475
  • [28] Uncertainty of Radiochromic Film Based Relative Dose Measurements
    Devic, S.
    Tomic, N.
    Lewis, D.
    Aldelaijan, S.
    DeBlois, F.
    Seuntjens, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3634 - 3634
  • [29] Radiochromic Film Measurement of Nanoparticle Radiation Dose Enhancement
    Buczek, M.
    Lawes, G.
    Snyder, M.
    Hillman, Y.
    Rakowski, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [30] LINEARIZATION OF THE RADIOCHROMIC FILM DOSIMETRY SYSTEM DOSE RESPONSE
    Tomic, Nada
    Seuntjens, Jan
    DeBlois, Francois
    Devic, Slobodan
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S9 - S10