Prediction of Left Main or 3-Vessel Disease Using Myocardial Perfusion Reserve on Dynamic Thallium-201 Single-Photon Emission Computed Tomography With a Semiconductor Gamma Camera

被引:60
|
作者
Shiraishi, Shinya [1 ]
Sakamoto, Fumi [1 ]
Tsuda, Noriko [1 ]
Yoshida, Morikatsu [1 ]
Tomiguchi, Seiji [2 ]
Utsunomiya, Daisuke [1 ]
Ogawa, Hisao [3 ]
Yamashita, Yasuyuki [1 ]
机构
[1] Kumamoto Univ, Grad Sch Life Sci, Dept Diagnost Radiol, Kumamoto 8608556, Japan
[2] Kumamoto Univ, Dept Diagnost Med Imaging, Sch Hlth Fac Life Sci, Kumamoto, Japan
[3] Kumamoto Univ, Dept Cardiovasc Med, Grad Sch Life Sci, Kumamoto, Japan
关键词
Balanced ischemia; Myocardial perfusion reserve; Semiconductor gamma camera; Thallium-201; Three-vessel disease; TRANSIENT ISCHEMIC DILATION; CORONARY-ARTERY-DISEASE; FLOW RESERVE; WALL-MOTION; BLOOD-FLOW; SPECT; QUANTIFICATION; PET; TRACER; PLAQUE;
D O I
10.1253/circj.CJ-14-0932
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Myocardial perfusion imaging (MPI) may fail to detect balanced ischemia. We evaluated myocardial perfusion reserve (MPR) using Tl dynamic single-photon emission computed tomography (SPECT) and a novel cadmium zinc telluride (CZT) camera for predicting 3-vessel or left main coronary artery disease (CAD). Methods and Results: A total of 55 consecutive patients with suspected CAD underwent SPECT-MPI and coronary angiography. The MPR index was calculated using the standard 2-compartment kinetic model. We analyzed the utility of MPR index, other SPECT findings, and various clinical variables. On multivariate analysis, MPR index and history of previous myocardial infarction (MI) predicted left main and 3-vessel disease. The area under the receiver operating characteristic curve was 0.81 for MPR index, 0.699 for history of previous MI, and 0.86 for MPR index plus history of previous MI. MPR index <= 1.5 yielded the highest diagnostic accuracy. Sensitivity, specificity, and accuracy were 86%, 78%, and 80%, respectively, for MPR index, 64%, 76%, 73% for previous MI, and 57%, 93%, and 84% for MPR index plus history of previous MI. Conclusions: Quantification of MPR using dynamic SPECT and a novel CZT camera may identify balanced ischemia in patients with left main or 3-vessel disease.
引用
收藏
页码:623 / 631
页数:9
相关论文
共 50 条
  • [31] The Dobutamine Stress Test With Thallium-201 Single-Photon Emission Computed Tomography and Radionuclide Angiography: Postinfarction Study
    Coma-Canella, Isabel
    Gomez Martinez, Maria del Val
    Rodrigo, Francisco
    Castro Beiras, Jose Manuel
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (02) : 399 - 406
  • [32] Diagnostic and prognostic value of dobutamine thallium-201 single-photon emission computed tomography after heart transplantation
    Wu, YW
    Yen, RF
    Lee, CM
    Ho, YL
    Chou, NK
    Wang, SS
    Huang, PJ
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (05): : 544 - 550
  • [33] PREDICTION OF LEFT MAIN AND LEFT MAIN EQUIVALENT DISEASE BY SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY THALLIUM IMAGING
    HEO, JK
    NGUYEN, T
    ISKANDRIAN, A
    CLINICAL RESEARCH, 1990, 38 (02): : A378 - A378
  • [34] On the generation of short-axis and radial long-axis slices in thallium-201 myocardial perfusion single-photon emission tomography
    Department of Nuclear Medicine, University Hospital Maastricht, Netherlands
    不详
    不详
    Eur. J. Nucl. Med. Mol. Imaging, 8 (924-931):
  • [35] On the generation of short-axis and radial long-axis slices in thallium-201 myocardial perfusion single-photon emission tomography
    vanHastenberg, RPJM
    Kemerink, GJ
    Hasman, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (08): : 924 - 931
  • [36] Nonlimited exercise test combined with high-dose dipyridamole for thallium-201 myocardial single-photon emission computed tomography in coronary artery disease
    LeGuludec, D
    Daou, D
    Faraggi, M
    Foult, JM
    Lebtahi, R
    Sarda, L
    Navarro, P
    Raynal, X
    Sotirov, Y
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 1997, 21 (03): : 126 - 132
  • [37] Role of adenosine in pathogenesis of syndrome X: Assessment with coronary hemodynamic measurements and thallium-201 myocardial single-photon emission computed tomography
    Inobe, Y
    Kugiyama, K
    Morita, E
    Kawano, H
    Okumura, K
    Tomiguchi, S
    Tsuji, A
    Kojima, A
    Takahashi, M
    Yasue, H
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (04) : 890 - 896
  • [38] Comparison of defect size between thallium-201 and technetium-99m tetrofosmin myocardial single-photon emission computed tomography in patients with single-vessel coronary artery disease
    Matsunari, I
    Fujino, S
    Taki, J
    Senma, J
    Aoyama, T
    Wakasugi, T
    Hirai, J
    Saga, T
    Tonami, N
    Hisada, K
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (05): : 350 - 354
  • [39] Comparison of transesophageal Doppler coronary flow reserve measurements with thallium-201 single-photon emission computed tomography imaging in assessment of left anterior descending artery stenoses
    Zehetgruber, M
    Mortl, D
    Porenta, G
    Mundigler, G
    Christ, G
    Lengauer, R
    Stix, G
    Probst, P
    Maurer, G
    Sochor, H
    Siostrzonek, P
    CLINICAL CARDIOLOGY, 1998, 21 (04) : 247 - 252
  • [40] Application of a novel automatic tissue-tracking system to detect left ventricular segments with perfusion abnormality: Comparison with thallium-201 single-photon emission computed tomography
    Sukmawan, R
    Watanabe, N
    Yoshitani, H
    Okahashi, N
    Wada, N
    Koyama, Y
    Yoshida, K
    CIRCULATION, 2004, 110 (17) : 715 - 715