Cryogenic optical performance of the Cassini Composite InfraRed Spectrometer (CIRS) flight telescope

被引:1
|
作者
Losch, P [1 ]
Lyons, JJ [1 ]
Hagopian, J [1 ]
机构
[1] NASA, Goddard Space Flight Ctr, Opt Branch, Greenbelt, MD 20771 USA
来源
CRYOGENIC OPTICAL SYSTEMS AND INSTRUMENTS VIII | 1998年 / 3435卷
关键词
cryogenic; optical test; encircled energy; beryllium cassegrain telescope;
D O I
10.1117/12.323742
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Cassini Composite InfraRed Spectrometer (CIRS) half-meter diameter beryllium flight telescope's optical performance was tested at the instrument operating temperature of 170 Kelvin. The telescope components were designed at Goddard Space Flight Center (GSFC) but fabricated out-of-house and then assembled, aligned, and tested upon receipt at GSFC. A 24-inch aperture cryogenic test facility utilizing a 1024 x 1024 CCD array was developed at GSFC specifically for this test. The telescope's image quality (measured as encircled energy), boresight stability and focus stability were measured. The gold coated beryllium design exceeded the cold image performance requirement of 80% encircled energy within a 460 micron diameter circle.
引用
收藏
页码:19 / 29
页数:11
相关论文
共 50 条
  • [41] TELESCOPE - OPTICAL-SYSTEM PERFORMANCE ANALYSIS FOR THE CRYOGENIC LIMB ARRAY ETALON SPECTROMETER (CLAES) ON THE UPPER ATMOSPHERIC RESEARCH SATELLITE
    ROCHE, AE
    FORNEY, PB
    MORROW, HE
    ANAPOL, M
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1983, 430 : 106 - 114
  • [42] The nitrogen isotopic ratio in Jupiter's atmosphere from observations by the Composite Infrared Spectrometer on the Cassini spacecraft
    Abbas, MM
    LeClair, A
    Owen, T
    Conrath, BJ
    Flasar, FM
    Kunde, VG
    Nixon, CA
    Achterberg, RK
    Bjoraker, G
    Jennings, DJ
    Orton, G
    Romani, PN
    ASTROPHYSICAL JOURNAL, 2004, 602 (02): : 1063 - 1074
  • [43] Cryogenic filter- and spectrometer wheels for the Mid Infrared Instrument (MIRI) of the James Webb Space Telescope (JWST)
    Lemke, D.
    Boehm, A.
    de Bonis, F.
    Ebert, A.
    Gross, T.
    Groezinger, U.
    Henning, T.
    Hinz, M.
    Hofferbert, R.
    Huber, A.
    Krause, O.
    Kuhlmann, S.
    Luichtel, G.
    Ramos, J.
    Rohloff, R. -R.
    Stein, C.
    Trunz, M.
    Uebele, M.
    Weidlich, K.
    OPTOMECHANICAL TECHNOLOGIES FOR ASTRONOMY, PTS 1 AND 2, 2006, 6273
  • [44] A CRYOGENIC INFRARED DUAL OPTICAL CHANNEL INTERFEROMETER-SPECTROMETER FOR UPPER ATMOSPHERIC MEASUREMENTS
    THURGOOD, VA
    HUPPI, RJ
    7TH INTERNATIONAL CONFERENCE ON FOURIER TRANSFORM SPECTROSCOPY, 1989, 1145 : 591 - 594
  • [45] Design and Performance of the Upgraded Mid-infrared Spectrometer and Imager (MIRSI) on the NASA Infrared Telescope Facility
    Hora, Joseph L.
    Trilling, David E.
    Lopez-Oquendo, Andy J.
    Smith, Howard A.
    Mommert, Michael
    Moskovitz, Nicholas
    Foster, Chris
    Connelley, Michael S.
    Lockhart, Charles
    Rayner, John T.
    Bus, Schelte J.
    Watanabe, Darryl
    Bergknut, Lars
    Bonnet, Morgan
    Tokunaga, Alan
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2024, 136 (10)
  • [46] Raman Laser Spectrometer optical head: flight model performance verification
    Santiago, A.
    Ramos, G.
    Sanz-Palomino, M.
    Gordillo, C.
    Cabrero, J.
    Moral, A. G.
    Prieto, J. A. R.
    Canora, C. P.
    Belenguer, T.
    Canchal, R.
    Gallego, P.
    Escribano, D.
    Lopez-Reyes, G.
    Rull, F.
    SPACE TELESCOPES AND INSTRUMENTATION 2018: OPTICAL, INFRARED, AND MILLIMETER WAVE, 2018, 10698
  • [47] Design and status of an optical and near-infrared spectrometer for the IRSF 1.4m Telescope
    Nagayama, Takahiro
    Kurita, Mikio
    Kino, Masaru
    Mori, Daisuke
    Kokusho, Takuma
    GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY IV, 2012, 8446
  • [48] James Webb Space Telescope optical performance predictions post cryogenic vacuum tests
    Lightsey, Paul A.
    Knight, J. Scott
    Barto, Allison
    Smith, Koby
    Chonis, Taylor
    Coyle, Laura
    Acton, Scott
    Rohrbach, Scott
    Mehalick, Kim
    Feinberg, Lee
    Hayden, William
    Atkinson, Charles
    Wells, Conrad
    Hadaway, James
    SPACE TELESCOPES AND INSTRUMENTATION 2018: OPTICAL, INFRARED, AND MILLIMETER WAVE, 2018, 10698
  • [49] In-flight performance and calibration of the infrared array camera (IRAC) for the Spitzer Space Telescope
    Hora, JL
    Fazio, GG
    Allen, LE
    Ashby, MLN
    Barmby, P
    Deutsch, LK
    Huang, JS
    Marengo, M
    Megeath, ST
    Melnick, GJ
    Pahre, MA
    Patten, BM
    Smith, HA
    Wang, Z
    Willner, SP
    Hoffmann, WF
    Pipher, JL
    Forrest, WJ
    McMurty, CW
    McCreight, CR
    McKelvey, ME
    McMurray, RE
    Moseley, SH
    Arendt, RG
    Mentzell, JE
    Marx, CT
    Fixsen, DJ
    Tollestrup, EV
    Eisenhardt, PR
    Stern, D
    Gorjian, V
    Bhattacharya, B
    Carey, SJ
    Glaccum, WJ
    Lacy, M
    Lowrance, PJ
    Laine, S
    Nelson, BO
    Reach, WT
    Stauffer, JR
    Surace, JA
    Wilson, G
    Wright, EL
    OPTICAL, INFRARED, AND MILLIMETER SPACE TELESCOPES, PTS 1-3, 2004, 5487 : 77 - 92
  • [50] Design and flight performance of a space borne 3He refrigerator for the infrared telescope in space
    Freund, MM
    Duband, L
    Lange, AE
    Matsumoto, T
    Murakami, H
    Hirao, T
    Sato, S
    CRYOGENICS, 1998, 38 (04) : 435 - 443