Evaluation of a Wearable Body Monitoring Device During Treadmill Walking and Jogging in Patients With Fibromyalgia Syndrome

被引:11
|
作者
Munguia-Izquierdo, Diego [1 ]
Santalla, Alfredo
Legaz-Arrese, Alejandro [2 ]
机构
[1] Univ Pablo Olavide, Dept Deporte & Informat, Sect Phys Educ & Sports, Seville 41013, Spain
[2] Univ Zaragoza, Sect Phys Educ & Sports, Zaragoza, Spain
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2012年 / 93卷 / 01期
关键词
Exercise; Fibromyalgia; Rehabilitation; PHYSICAL-ACTIVITY QUESTIONNAIRE; ENERGY-EXPENDITURE; INDIRECT CALORIMETRY; MULTISENSOR ARMBAND; ACCELEROMETER; EXERCISE; VALIDITY; VALIDATION; INSTRUMENTS; RELIABILITY;
D O I
10.1016/j.apmr.2011.08.021
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Munguia-Izquierdo D, Santalla A, Legaz-Arrese A. Evaluation of a wearable body monitoring device during treadmill walking and jogging in patients with fibromyalgia syndrome. Arch Phys Med Rehabil 2012;93:115-22. Objective: To evaluate the reliability and validity of a body monitoring device against measures obtained from indirect calorimetry (IC) in patients with fibromyalgia syndrome (FMS) during various incremental exercise intensities. Design: Cross-sectional reliability and validity study. Setting: Testing was completed in a university exercise physiology laboratory. Participants: Women (N=25) with FMS, with a mean age +/- SD of 48.6 +/- 8.4 years and a median symptom duration of 15 years (25th-75th percentiles, 10-23y), were recruited to the study. Interventions: Not applicable. Main Outcome Measures: Patients walked and jogged on a treadmill at 4 intensities (50m.min(-1), 0% grade [n=25]; 83.3m.min(-1), 0% grade [n=25]; 116.7m.min(-1), 0% grade [n=21]; 116.7m.min(-1), 2.5% grade [n=13]) during 2 measurement conditions, while IC and a multiple-sensor body monitor measured energy expenditure (EE). The differences between the readings (test 1 test 2) and the SD of the differences, intraclass correlation coefficient (ICC), 95% confidence interval (CI) for the ICC, coefficient of repeatability, intrapatient SD, standard error of mean (SEM), minimal detectable change, Wilcoxon signed-rank test, and Bland-Altman graphs were used to examine reliability. The magnitude of the associations between IC and the body monitoring device, ICC, 95% CI for the ICC, paired t tests, and Bland-Altman graphs were used to examine the validity of the body monitoring device versus the IC. Results: Moderate to excellent test-retest reliability was found for the 4 bouts of exercise (ICC = .73-.76). The SEM and minimal detectable change were satisfactory for the 4 bouts of exercise (.54-1.18kcal.min(-1) and 1.51-3.28kcal-min(-1), respectively). The differences mean between test and retest were lower than the SEM for the 4 bouts of exercise, varying from -.17 to .14kcal.min(-1). No significant differences were found between test and retest for any bout. The Bland-Altman plots and the coefficients of repeatability indicated that the differences between repeated tests would lie within 2 SDs in 95% of the cases for the 4 bouts of exercise. Significant associations were found between the body monitoring device and IC measurements of EE for the 4 bouts of exercise (r=.87-.99). The differences for all bouts between the 2 methods were nonsignificant, except for the second bout (P <.001). The ICCs and Bland-Altman plots of EE for the 4 bouts showed high agreement (ICCs=.84-.99) and sufficient accuracy for quantifying EE during exercise in patients with FMS. Conclusions: The body monitoring device provided a valid and reliable estimate of EE in patients with FMS during walking on horizontal and inclined surfaces in a laboratory setting across various exercise intensities.
引用
收藏
页码:115 / 122
页数:8
相关论文
共 50 条
  • [41] Ambulation training of neurological patients on the treadmill with a new Walking Assistance and Rehabilitation Device (WARD)
    Gazzani, F
    Bernardi, M
    Macaluso, A
    Coratella, D
    Ditunno, JF
    Castellano, V
    Torre, M
    Macellari, V
    Marchetti, M
    SPINAL CORD, 1999, 37 (05) : 336 - 344
  • [42] Gait alterations during walking with partial body weight supported on a treadmill and over the ground
    Barela, Ana Maria F.
    Gama, Gabriela L.
    Russo-Junior, Douglas, V
    Celestino, Melissa L.
    Barela, Jose A.
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [43] Gait alterations during walking with partial body weight supported on a treadmill and over the ground
    Ana Maria F. Barela
    Gabriela L. Gama
    Douglas V. Russo-Junior
    Melissa L. Celestino
    José A. Barela
    Scientific Reports, 9
  • [44] PREDICTION OF LEAN BODY MASS WITH FEATURES EXTRACTED FROM WEARABLE DEVICE FOR BODY COMPOSITION MONITORING
    Lee, S. M.
    Park, M.
    Yoon, H. -J.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A166 - A166
  • [45] Oxygen consumption during treadmill walking with and without body weight support in patients with hemiparesis after stroke and in healthy subjects
    Danielsson, A
    Sunnerhagen, KS
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2000, 81 (07): : 953 - 957
  • [46] Rational Design of a Surface Acoustic Wave Device for Wearable Body Temperature Monitoring
    Xie, Yudi
    Deng, Minglong
    Chen, Jinkai
    Duan, Yue
    Zhang, Jikai
    Mu, Danyu
    Dong, Shurong
    Luo, Jikui
    Jin, Hao
    Kakio, Shoji
    MICROMACHINES, 2024, 15 (05)
  • [47] Walking during body-weight-supported treadmill training and acute responses to varying walking speed and body-weight support in ambulatory patients post-stroke
    Aaslund, Mona Kristin
    Helbostad, Jorunn Laegdheim
    Moe-Nilssen, Rolf
    PHYSIOTHERAPY THEORY AND PRACTICE, 2013, 29 (04) : 278 - 289
  • [48] Similarity of Center of Pressure Progression during Walking and Jogging of Anterior Cruciate Ligament Deficient Patients
    Huang, Hongshi
    Qiu, Jianwei
    Liu, Tianlin
    Yu, Yuanyuan
    Guo, Qinwei
    Luo, Dingsheng
    Ao, Yingfang
    PLOS ONE, 2017, 12 (01):
  • [49] Variability of spatiotemporal gait parameters in children with and without Down syndrome during treadmill walking
    Beerse, Matthew
    Henderson, Gena
    Liang, Huaqing
    Ajisafe, Toyin
    Wu, Jianhua
    GAIT & POSTURE, 2019, 68 : 207 - 212
  • [50] A catalog of validity indices for step counting wearable technologies during treadmill walking: the CADENCE-adults study
    Mora-Gonzalez, Jose
    Gould, Zachary R.
    Moore, Christopher C.
    Aguiar, Elroy J.
    Ducharme, Scott W.
    Schuna, John M., Jr.
    Barreira, Tiago, V
    Staudenmayer, John
    McAvoy, Cayla R.
    Boikova, Mariya
    Miller, Taavy A.
    Tudor-Locke, Catrine
    INTERNATIONAL JOURNAL OF BEHAVIORAL NUTRITION AND PHYSICAL ACTIVITY, 2022, 19 (01)