Evaluation of a Wearable Body Monitoring Device During Treadmill Walking and Jogging in Patients With Fibromyalgia Syndrome

被引:11
|
作者
Munguia-Izquierdo, Diego [1 ]
Santalla, Alfredo
Legaz-Arrese, Alejandro [2 ]
机构
[1] Univ Pablo Olavide, Dept Deporte & Informat, Sect Phys Educ & Sports, Seville 41013, Spain
[2] Univ Zaragoza, Sect Phys Educ & Sports, Zaragoza, Spain
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 2012年 / 93卷 / 01期
关键词
Exercise; Fibromyalgia; Rehabilitation; PHYSICAL-ACTIVITY QUESTIONNAIRE; ENERGY-EXPENDITURE; INDIRECT CALORIMETRY; MULTISENSOR ARMBAND; ACCELEROMETER; EXERCISE; VALIDITY; VALIDATION; INSTRUMENTS; RELIABILITY;
D O I
10.1016/j.apmr.2011.08.021
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Munguia-Izquierdo D, Santalla A, Legaz-Arrese A. Evaluation of a wearable body monitoring device during treadmill walking and jogging in patients with fibromyalgia syndrome. Arch Phys Med Rehabil 2012;93:115-22. Objective: To evaluate the reliability and validity of a body monitoring device against measures obtained from indirect calorimetry (IC) in patients with fibromyalgia syndrome (FMS) during various incremental exercise intensities. Design: Cross-sectional reliability and validity study. Setting: Testing was completed in a university exercise physiology laboratory. Participants: Women (N=25) with FMS, with a mean age +/- SD of 48.6 +/- 8.4 years and a median symptom duration of 15 years (25th-75th percentiles, 10-23y), were recruited to the study. Interventions: Not applicable. Main Outcome Measures: Patients walked and jogged on a treadmill at 4 intensities (50m.min(-1), 0% grade [n=25]; 83.3m.min(-1), 0% grade [n=25]; 116.7m.min(-1), 0% grade [n=21]; 116.7m.min(-1), 2.5% grade [n=13]) during 2 measurement conditions, while IC and a multiple-sensor body monitor measured energy expenditure (EE). The differences between the readings (test 1 test 2) and the SD of the differences, intraclass correlation coefficient (ICC), 95% confidence interval (CI) for the ICC, coefficient of repeatability, intrapatient SD, standard error of mean (SEM), minimal detectable change, Wilcoxon signed-rank test, and Bland-Altman graphs were used to examine reliability. The magnitude of the associations between IC and the body monitoring device, ICC, 95% CI for the ICC, paired t tests, and Bland-Altman graphs were used to examine the validity of the body monitoring device versus the IC. Results: Moderate to excellent test-retest reliability was found for the 4 bouts of exercise (ICC = .73-.76). The SEM and minimal detectable change were satisfactory for the 4 bouts of exercise (.54-1.18kcal.min(-1) and 1.51-3.28kcal-min(-1), respectively). The differences mean between test and retest were lower than the SEM for the 4 bouts of exercise, varying from -.17 to .14kcal.min(-1). No significant differences were found between test and retest for any bout. The Bland-Altman plots and the coefficients of repeatability indicated that the differences between repeated tests would lie within 2 SDs in 95% of the cases for the 4 bouts of exercise. Significant associations were found between the body monitoring device and IC measurements of EE for the 4 bouts of exercise (r=.87-.99). The differences for all bouts between the 2 methods were nonsignificant, except for the second bout (P <.001). The ICCs and Bland-Altman plots of EE for the 4 bouts showed high agreement (ICCs=.84-.99) and sufficient accuracy for quantifying EE during exercise in patients with FMS. Conclusions: The body monitoring device provided a valid and reliable estimate of EE in patients with FMS during walking on horizontal and inclined surfaces in a laboratory setting across various exercise intensities.
引用
收藏
页码:115 / 122
页数:8
相关论文
共 50 条
  • [31] Evaluation of psychophysiological asymmetry in patients with fibromyalgia syndrome
    Mitani, Yuko
    Fukunaga, Mikihiko
    Kanbara, Kenji
    Takebayashi, Naoki
    Ishino, Shinichiro
    Nakai, Yoshihide
    APPLIED PSYCHOPHYSIOLOGY AND BIOFEEDBACK, 2006, 31 (03) : 217 - 225
  • [32] Evaluation of a wearable, wireless device for remote Vital Signs monitoring in post-operative patients
    Downey, C.
    Jayne, D.
    BRITISH JOURNAL OF SURGERY, 2016, 103 : 85 - 85
  • [33] BLE Analysis and Experimental Evaluation in a Walking Monitoring Device for Elderly
    Del Campo, Antonio
    Montanini, Laura
    Perla, Davide
    Gambi, Ennio
    Spinsante, Susanna
    2016 IEEE 27TH ANNUAL INTERNATIONAL SYMPOSIUM ON PERSONAL, INDOOR, AND MOBILE RADIO COMMUNICATIONS (PIMRC), 2016, : 2415 - 2420
  • [34] Evaluation of a wearable, wireless device for remote vital signs monitoring in post-operative patients
    Downey, C. L.
    Dwyer, M.
    Jayne, D. G.
    BRITISH JOURNAL OF SURGERY, 2016, 103 : 30 - 30
  • [35] Performance Evaluation of Wearable Wireless Body Area Networks during Walking Motions in 444.5 MHz and 2450 MHz
    Takizawa, Kenichi
    Watanabe, Katsuhiro
    Kumazawa, Masaki
    Hamada, Yusuke
    Ikegami, Tetsushi
    Hamaguchi, Kiyoshi
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 370 - 373
  • [36] TREADMILL WALKING PROTOCOL FOR THE DIAGNOSTIC EVALUATION AND EXERCISE PROGRAMMING OF CARDIAC PATIENTS
    ZOHMAN, LR
    YOUNG, JL
    KATTUS, AA
    AMERICAN JOURNAL OF CARDIOLOGY, 1983, 51 (07): : 1081 - 1086
  • [37] Body reprogramming for fibromyalgia and central sensitivity syndrome: A preliminary evaluation
    Lanario, Joseph W.
    Hudson, Esther
    Locher, Cosima
    Dee, Annily
    Elliot, Kerry
    Davies, Anthony F.
    SAGE OPEN MEDICINE, 2023, 11
  • [38] Effect of body weight support on muscle activation during walking on a lower body positive pressure treadmill
    Kristiansen, Mathias
    Odderskaer, Nikolaj
    Kristensen, Daniel Haaning
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2019, 48 : 9 - 16
  • [39] PREDICTION OF PAO2 DURING TREADMILL WALKING IN PATIENTS WITH COPD
    KURIHARA, N
    FUJIMOTO, S
    TERAKAWA, K
    YAMAMOTO, M
    TAKEDA, T
    CHEST, 1987, 91 (03) : 328 - 332
  • [40] Ambulation training of neurological patients on the treadmill with a new Walking Assistance and Rehabilitation Device (WARD)
    F Gazzani
    M Bernardi
    A Macaluso
    D Coratella
    JF Ditunno
    V Castellano
    M Torre
    V Macellari
    M Marchetti
    Spinal Cord, 1999, 37 : 336 - 344