Metal artifacts from sternal wires: evaluation of virtual monoenergetic images from spectral-detector CT for artifact reduction

被引:10
|
作者
Laukamp, Kai Roman [1 ,2 ,3 ,4 ]
Hokamp, Nils Grosse [1 ,2 ,3 ,4 ]
Alabar, Omar [1 ,2 ]
Obmann, Verena Carola [1 ,2 ]
Lennartz, Simon [3 ,4 ]
Zopfs, David [3 ,4 ]
Gilkeson, Robert [1 ,2 ]
Ramaiya, Nikhil [1 ,2 ]
Gupta, Amit [1 ,2 ]
机构
[1] Univ Hosp Cleveland, Med Ctr, Dept Radiol, 11000 Euclid Ave, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Radiol, Cleveland, OH 44106 USA
[3] Univ Cologne, Fac Med, Inst Diagnost & Intervent Radiol, Cologne, Germany
[4] Univ Cologne, Univ Hosp Cologne, Cologne, Germany
关键词
X-ray computed tomography; Artifacts; Sternal wires; Neoplasm staging; Thoracic surgery; Spectral-detector CT; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; ORTHOPEDIC HARDWARE; RECONSTRUCTION; EXTRAPOLATION; SOFTWARE; IMPLANTS; SPINE;
D O I
10.1016/j.clinimag.2019.12.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In chest imaging, sternal wires can cause metal artifacts that hamper depiction of surrounding soft tissue and bone. This study investigated if these artifacts may be reduced by means of virtual monoenergetic images (VMD obtained from a novel detector-based spectral CT scanner (SDCT) in comparison to conventional CT images (CI). Materials and methods: 30 patients with clinically indicated SDCT scans of the chest exhibiting artifacts due to sternal wires were included in this IRB-approved study. CI and VMI (40-200 keV, 10 keV increment) were reconstructed. Quantitative image analysis was conducted by ROI-based measurement of attenuation (HU) and standard deviation within the most pronounced hypo- and hyperdense artifacts. Visually, artifact reduction and diagnostic assessment of surrounding soft tissue as well as sternal bone were independently rated by two radiologists on 5-point Likert-scales. Results: In comparison to CI, high-keV VMI showed an effective reduction of hypo- and hyperattenuating parasternal artifacts, as corrected HU-values approximated their true expected values (hypodense: CI -66.2 +/- 70.8; VMI200keV 2.4 +/- 29.2; hyperdense: CI 156.7 +/- 70.8HU; VMI200keV 76.9 +/- 45.4, both p < 0.05). In addition, image noise was significantly lower in high-keV VMI compared to Cl. Subjective analysis confirmed that VMI of 100 keV significantly reduced artifacts and improved diagnostic assessment of surrounding soft tissue and bone. Interrater-agreement was excellent (intraclass-correlation-coefficient = 0.83). Conclusions: High-keV VMI yielded a significant reduction of artifacts from sternal wires and improved assessment of surrounding structures.
引用
收藏
页码:249 / 256
页数:8
相关论文
共 50 条
  • [41] Reduction of metal artifacts from unilateral hip arthroplasty on dual-energy CT with metal artifact reduction software
    Yue, Dong
    Rong, Cheng Fan
    Ning, Cai
    Liang, Hu
    Lian, Liu Ai
    Xin, Wang Ru
    Hong, Luo Ya
    ACTA RADIOLOGICA, 2018, 59 (07) : 853 - 860
  • [42] Virtual monoenergetic images preserve diagnostic assessability in contrast media reduced abdominal spectral detector CT
    Lennartz, Simon
    Hokamp, Nils Grosse
    Zaeske, Charlotte
    Zopfs, David
    Bratke, Grischa
    Glauner, Andreas
    Maintz, David
    Persigehl, Thorsten
    Chang, De-Hua
    Hickethier, Tilman
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1113):
  • [43] Optimal combination periprosthetic vasculature visualization and metal artifact reduction by spectral computed tomography using virtual monoenergetic images in total hip arthroplasty
    Jie Zhao
    Qiang Cheng
    Chuan Liu
    Qiqi Wang
    Yuchan Lv
    Ziyi Tang
    Yuxi Luo
    Haitao Yang
    Insights into Imaging, 14
  • [44] Optimal combination periprosthetic vasculature visualization and metal artifact reduction by spectral computed tomography using virtual monoenergetic images in total hip arthroplasty
    Zhao, Jie
    Cheng, Qiang
    Liu, Chuan
    Wang, Qiqi
    Lv, Yuchan
    Tang, Ziyi
    Luo, Yuxi
    Yang, Haitao
    INSIGHTS INTO IMAGING, 2023, 14 (01)
  • [45] Assessment of arterially hyper-enhancing liver lesions using virtual monoenergetic images from spectral detector CT: phantom and patient experience
    Hokamp, N. Grosse
    Hoeink, A. J.
    Doerner, J.
    Jordan, D. W.
    Pahn, G.
    Persigehl, T.
    Maintz, D.
    Haneder, S.
    ABDOMINAL RADIOLOGY, 2018, 43 (08) : 2066 - 2074
  • [46] Assessment of arterially hyper-enhancing liver lesions using virtual monoenergetic images from spectral detector CT: phantom and patient experience
    N. Große Hokamp
    A. J. Höink
    J. Doerner
    D. W. Jordan
    G. Pahn
    T. Persigehl
    D. Maintz
    S. Haneder
    Abdominal Radiology, 2018, 43 : 2066 - 2074
  • [47] Virtual monoenergetic images and post-processing algorithms effectively reduce CT artifacts from intracranial aneurysm treatment
    Zopfs, David
    Lennartz, Simon
    Pennig, Lenhard
    Glauner, Andreas
    Abdullayev, Nuran
    Bremm, Johannes
    Hokamp, Nils Grosse
    Persigehl, Thorsten
    Kabbasch, Christoph
    Borggrefe, Jan
    Laukamp, Kai Roman
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [48] Virtual monoenergetic images and post-processing algorithms effectively reduce CT artifacts from intracranial aneurysm treatment
    David Zopfs
    Simon Lennartz
    Lenhard Pennig
    Andreas Glauner
    Nuran Abdullayev
    Johannes Bremm
    Nils Große Hokamp
    Thorsten Persigehl
    Christoph Kabbasch
    Jan Borggrefe
    Kai Roman Laukamp
    Scientific Reports, 10
  • [49] Virtual Monochromatic Spectral Imaging with Fast Kilovoltage Switching: Reduction of Metal Artifacts at CT
    Pessis, Eric
    Campagna, Raphael
    Sverzut, Jean-Michel
    Bach, Fabienne
    Rodallec, Mathieu
    Guerini, Henri
    Feydy, Antoine
    Drape, Jean-Luc
    RADIOGRAPHICS, 2013, 33 (02) : 573 - 583
  • [50] Virtual non-contrast for evaluation of liver parenchyma and vessels: results from 25 patients using multi-phase spectral-detector CT
    Laukamp, Kai Roman
    Ho, Vivian
    Obmann, Verena Carola
    Herrmann, Karin
    Gupta, Amit
    Borggrefe, Jan
    Lennartz, Simon
    Hokamp, Nils Grosse
    Ramaiya, Nikhil
    ACTA RADIOLOGICA, 2020, 61 (08) : 1143 - 1152