Metal artifacts from sternal wires: evaluation of virtual monoenergetic images from spectral-detector CT for artifact reduction

被引:10
|
作者
Laukamp, Kai Roman [1 ,2 ,3 ,4 ]
Hokamp, Nils Grosse [1 ,2 ,3 ,4 ]
Alabar, Omar [1 ,2 ]
Obmann, Verena Carola [1 ,2 ]
Lennartz, Simon [3 ,4 ]
Zopfs, David [3 ,4 ]
Gilkeson, Robert [1 ,2 ]
Ramaiya, Nikhil [1 ,2 ]
Gupta, Amit [1 ,2 ]
机构
[1] Univ Hosp Cleveland, Med Ctr, Dept Radiol, 11000 Euclid Ave, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Dept Radiol, Cleveland, OH 44106 USA
[3] Univ Cologne, Fac Med, Inst Diagnost & Intervent Radiol, Cologne, Germany
[4] Univ Cologne, Univ Hosp Cologne, Cologne, Germany
关键词
X-ray computed tomography; Artifacts; Sternal wires; Neoplasm staging; Thoracic surgery; Spectral-detector CT; DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; ORTHOPEDIC HARDWARE; RECONSTRUCTION; EXTRAPOLATION; SOFTWARE; IMPLANTS; SPINE;
D O I
10.1016/j.clinimag.2019.12.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: In chest imaging, sternal wires can cause metal artifacts that hamper depiction of surrounding soft tissue and bone. This study investigated if these artifacts may be reduced by means of virtual monoenergetic images (VMD obtained from a novel detector-based spectral CT scanner (SDCT) in comparison to conventional CT images (CI). Materials and methods: 30 patients with clinically indicated SDCT scans of the chest exhibiting artifacts due to sternal wires were included in this IRB-approved study. CI and VMI (40-200 keV, 10 keV increment) were reconstructed. Quantitative image analysis was conducted by ROI-based measurement of attenuation (HU) and standard deviation within the most pronounced hypo- and hyperdense artifacts. Visually, artifact reduction and diagnostic assessment of surrounding soft tissue as well as sternal bone were independently rated by two radiologists on 5-point Likert-scales. Results: In comparison to CI, high-keV VMI showed an effective reduction of hypo- and hyperattenuating parasternal artifacts, as corrected HU-values approximated their true expected values (hypodense: CI -66.2 +/- 70.8; VMI200keV 2.4 +/- 29.2; hyperdense: CI 156.7 +/- 70.8HU; VMI200keV 76.9 +/- 45.4, both p < 0.05). In addition, image noise was significantly lower in high-keV VMI compared to Cl. Subjective analysis confirmed that VMI of 100 keV significantly reduced artifacts and improved diagnostic assessment of surrounding soft tissue and bone. Interrater-agreement was excellent (intraclass-correlation-coefficient = 0.83). Conclusions: High-keV VMI yielded a significant reduction of artifacts from sternal wires and improved assessment of surrounding structures.
引用
收藏
页码:249 / 256
页数:8
相关论文
共 50 条
  • [21] Metal artifacts in patients with large dental implants and bridges: combination of metal artifact reduction algorithms and virtual monoenergetic images provides an approach to handle even strongest artifacts
    Kai Roman Laukamp
    David Zopfs
    Simon Lennartz
    Lenhard Pennig
    David Maintz
    Jan Borggrefe
    Nils Große Hokamp
    European Radiology, 2019, 29 : 4228 - 4238
  • [22] Metal artifacts in patients with large dental implants and bridges: combination of metal artifact reduction algorithms and virtual monoenergetic images provides an approach to handle even strongest artifacts
    Laukamp, Kai Roman
    Zopfs, David
    Lennartz, Simon
    Pennig, Lenhard
    Maintz, David
    Borggrefe, Jan
    Hokamp, Nils Grosse
    EUROPEAN RADIOLOGY, 2019, 29 (08) : 4228 - 4238
  • [23] Reduction of microwave ablation needle related metallic artifacts using virtual monoenergetic images from dual-layer detector spectral CT in a rabbit model with VX2 tumor
    Guorong Wang
    Qinzong Gao
    Zhiwei Wang
    Xiaomei Lu
    Shenghui Yu
    Zhengyu Jin
    Scientific Reports, 11
  • [24] Reduction of microwave ablation needle related metallic artifacts using virtual monoenergetic images from dual-layer detector spectral CT in a rabbit model with VX2 tumor
    Wang, Guorong
    Gao, Qinzong
    Wang, Zhiwei
    Lu, Xiaomei
    Yu, Shenghui
    Jin, Zhengyu
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [25] Assessing the Severity of Metal Artifacts and Detectability of Lesions in CT Metal Artifact Reduction Images
    Topbas, C.
    Dong, F.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [26] Reduction of metal artifacts from knee tumor prostheses on CT images: value of the single energy metal artifact reduction (SEMAR) algorithm
    Zhang, Fang-Ling
    Li, Ruo-Cheng
    Zhang, Xiao-Ling
    Zhang, Zhao-Hui
    Ma, Ling
    Ding, Lei
    BMC CANCER, 2021, 21 (01)
  • [27] Reduction of metal artifacts from knee tumor prostheses on CT images: value of the single energy metal artifact reduction (SEMAR) algorithm
    Fang-ling Zhang
    Ruo-cheng Li
    Xiao-ling Zhang
    Zhao-hui Zhang
    Ling Ma
    Lei Ding
    BMC Cancer, 21
  • [28] Metal Artifact Reduction from CT Images Using Complementary MR Images
    Anderla, Andras A.
    Culibrk, Dubravko R.
    Delso, Gaspar
    2013 11TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS IN MODERN SATELLITE, CABLE AND BROADCASTING SERVICES (TELSIKS), VOLS 1 AND 2, 2013, : 337 - 340
  • [29] Quantifying potential reduction in contrast dose with monoenergetic images synthesized from dual-layer detector spectral CT
    Tsang, Derek S.
    Merchant, Thomas E.
    Merchant, Sophie E.
    Yagil, Hanna Smith Yoad
    Yagil, Yoad
    Hua, Chia-Ho
    BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1078):
  • [30] Effect of Virtual Monoenergetic Images From Spectral Detector Computed Tomography on Coronary Calcium Blooming
    Van Hedent, Steven
    Hokamp, Nils Grosse
    Kessner, Rivka
    Gilkeson, Robert
    Ros, Pablo R.
    Gupta, Amit
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 912 - 918