Submillisievert Radiation Dose Coronary CT Angiography: Clinical Impact of the Knowledge-Based Iterative Model Reconstruction

被引:17
|
作者
Iyama, Yuji [1 ,2 ]
Nakaura, Takeshi [1 ,2 ]
Kidoh, Masafumi [2 ]
Oda, Seitaro [2 ]
Utsunomiya, Daisuke [2 ]
Sakaino, Naritsugu [3 ]
Tokuyasu, Shinichi [4 ]
Osakabe, Hirokazu [4 ]
Harada, Kazunori [5 ]
Yamashita, Yasuyuki [2 ]
机构
[1] Amakusa Med Ctr, Diagnost Radiol, Kameba 854-1, Kumamoto 8630046, Japan
[2] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Kumamoto, Japan
[3] Amakusa Med Ctr, Dept Cardiovasc Internal Med, Kumamoto, Japan
[4] Philips Elect Japan, Tokyo, Japan
[5] Amakusa Med Ctr, Dept Surg, Kumamoto, Japan
关键词
Computed tomography (CT); iterative reconstruction; radiation dose; CARDIAC COMPUTED-TOMOGRAPHY; FILTERED BACK-PROJECTION; IMAGE QUALITY; ABDOMINAL CT; REDUCTION; ALGORITHM; NOISE; MBIR;
D O I
10.1016/j.acra.2016.07.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: The purpose of this study was to evaluate the noise and image quality of images reconstructed with a knowledge-based iterative model reconstruction (knowledge-based IMR) in ultra-low dose cardiac computed tomography (CT). Materials and Methods: We performed submillisievert radiation dose coronary CT angiography on 43 patients. We also performed a phantom study to evaluate the influence of object size with the automatic exposure control phantom. We reconstructed clinical and phantom studies with filtered back projection (FBP), hybrid iterative reconstruction (hybrid IR), and knowledge-based IMR. We measured effective dose of patients and compared CT number, image noise, and contrast noise ratio in ascending aorta of each reconstruction technique. We compared the relationship between image noise and body mass index for the clinical study, and object size for phantom study. Results: The mean effective dose was 0.98 +/- 0.25 mSv. The image noise of knowledge-based IMR images was significantly lower than those of FBP and hybrid IR images (knowledge-based IMR: 19.4 +/- 2.8; FBP: 126.7 +/- 35.0; hybrid IR: 48.8 +/- 12.8, respectively) (P < .01). The contrast noise ratio of knowledge based IMR images was significantly higher than those of FBP and hybrid IR images (knowledge based IMR: 29.1 +/- 5.4; FBP: 4.6 +/- 1.3; hybrid IR: 13.1 +/- 3.5, respectively) (P < .01). There were moderate correlations between image noise and body mass index in FBP (r = 0.57, P < .01) and hybrid IR techniques (r = 0.42, P < .01); however, these correlations were weak in knowledge-based IMR (r = 0.27, P < .01). Conclusion: Compared to FBP and hybrid IR, the knowledge-based IMR offers significant noise reduction and improvement in image quality in submillisievert radiation dose cardiac CT.
引用
收藏
页码:1393 / 1401
页数:9
相关论文
共 50 条
  • [41] Reduced radiation dose with model based iterative reconstruction coronary artery calcium scoring
    Chor, Andrew D.
    Leifer, Eric S.
    Yu, Jeannie H.
    Datta, Tanuka
    Bronson, Kathie C.
    Rollison, Shirley F.
    Schuzer, John L.
    Steveson, Chloe
    Shanbhag, Sujata M.
    Chen, Marcus Y.
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 111 : 1 - 5
  • [42] Iterative Reconstruction to Preserve Image Quality and Diagnostic Accuracy at Reduced Radiation Dose in Coronary CT Angiography An Intraindividual Comparison
    Yin, Wei-Hua
    Lu, Bin
    Li, Nan
    Han, Lei
    Hou, Zhi-Hui
    Wu, Run-Ze
    Wu, Yong-Jian
    Niu, Hong-Xia
    Jiang, Shi-Liang
    Krazinski, Aleksander W.
    Ebersberger, Ullrich
    Meinel, Felix G.
    Schoepf, U. Joseph
    JACC-CARDIOVASCULAR IMAGING, 2013, 6 (12) : 1239 - 1249
  • [43] Coronary CT Angiography with Use of Iterative Reconstruction Algorithm in Coronary Stenting: A Systematic Review of Image Quality, Diagnostic Value and Radiation Dose
    Al Shammakhi, Ahmed
    Sun, Zhonghua
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2015, 5 (01) : 103 - 109
  • [44] Iterative model reconstruction reduces calcified plaque volume in coronary CT angiography
    Karolyi, Mihaly
    Szilveszter, Balint
    Kolossvary, Marton
    Takx, Richard A. P.
    Celeng, Csilla
    Bartykowszki, Andrea
    Jermendy, Adam L.
    Panajotu, Alexisz
    Karady, Jlia
    Raaijmakers, Rolf
    Giepmans, Walter
    Merkely, Bela
    Maurovich-Horvat, Pal
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 87 : 83 - 89
  • [45] CT Radiation Dose and Iterative Reconstruction Techniques
    Padole, Atul
    Khawaja, Ranish Deedar Ali
    Kalra, Mannudeep K.
    Singh, Sarabjeet
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (04) : W384 - W387
  • [46] The Impact of Combining a Low-Tube Voltage Acquisition with Iterative Reconstruction on Total Iodine Dose in Coronary CT Angiography
    Van Cauteren, Toon
    Van Gompel, Gert
    Tanaka, Kaoru
    Verdries, Douwe E.
    Belsack, Dries
    Nieboer, Koenraad H.
    Willekens, Inneke
    Evans, Paul
    Macholl, Sven
    Verfaillie, Guy
    Droogmans, Steven
    de Mey, Johan
    Buls, Nico
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [47] Comparison of Knowledge-based Iterative Model Reconstruction and Hybrid Reconstruction Techniques for Liver CT Evaluation of Hypervascular Hepatocellular Carcinoma
    Park, Hyun Jeong
    Lee, Jeong Min
    Park, Sung Bin
    Lee, Jong Beum
    Jeong, Yoong Ki
    Yoon, Jeong Hee
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (06) : 863 - 871
  • [48] Radiation dose measurements in coronary CT angiography
    Sabarudin, Akmal
    Sun, Zhonghua
    WORLD JOURNAL OF CARDIOLOGY, 2013, 5 (12): : 459 - 464
  • [49] Coronary CT angiography with low radiation dose
    Lei Xu
    Zhaoqi Zhang
    The International Journal of Cardiovascular Imaging, 2010, 26 : 17 - 25
  • [50] Radiation dose reduction in CT coronary angiography
    Shapiro B.P.
    Young P.M.
    Kantor B.
    Choe Y.H.
    McCollough C.H.
    Gerber T.C.
    Current Cardiology Reports, 2010, 12 (1) : 59 - 67