Submillisievert Radiation Dose Coronary CT Angiography: Clinical Impact of the Knowledge-Based Iterative Model Reconstruction

被引:17
|
作者
Iyama, Yuji [1 ,2 ]
Nakaura, Takeshi [1 ,2 ]
Kidoh, Masafumi [2 ]
Oda, Seitaro [2 ]
Utsunomiya, Daisuke [2 ]
Sakaino, Naritsugu [3 ]
Tokuyasu, Shinichi [4 ]
Osakabe, Hirokazu [4 ]
Harada, Kazunori [5 ]
Yamashita, Yasuyuki [2 ]
机构
[1] Amakusa Med Ctr, Diagnost Radiol, Kameba 854-1, Kumamoto 8630046, Japan
[2] Kumamoto Univ, Grad Sch Med Sci, Dept Diagnost Radiol, Kumamoto, Japan
[3] Amakusa Med Ctr, Dept Cardiovasc Internal Med, Kumamoto, Japan
[4] Philips Elect Japan, Tokyo, Japan
[5] Amakusa Med Ctr, Dept Surg, Kumamoto, Japan
关键词
Computed tomography (CT); iterative reconstruction; radiation dose; CARDIAC COMPUTED-TOMOGRAPHY; FILTERED BACK-PROJECTION; IMAGE QUALITY; ABDOMINAL CT; REDUCTION; ALGORITHM; NOISE; MBIR;
D O I
10.1016/j.acra.2016.07.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: The purpose of this study was to evaluate the noise and image quality of images reconstructed with a knowledge-based iterative model reconstruction (knowledge-based IMR) in ultra-low dose cardiac computed tomography (CT). Materials and Methods: We performed submillisievert radiation dose coronary CT angiography on 43 patients. We also performed a phantom study to evaluate the influence of object size with the automatic exposure control phantom. We reconstructed clinical and phantom studies with filtered back projection (FBP), hybrid iterative reconstruction (hybrid IR), and knowledge-based IMR. We measured effective dose of patients and compared CT number, image noise, and contrast noise ratio in ascending aorta of each reconstruction technique. We compared the relationship between image noise and body mass index for the clinical study, and object size for phantom study. Results: The mean effective dose was 0.98 +/- 0.25 mSv. The image noise of knowledge-based IMR images was significantly lower than those of FBP and hybrid IR images (knowledge-based IMR: 19.4 +/- 2.8; FBP: 126.7 +/- 35.0; hybrid IR: 48.8 +/- 12.8, respectively) (P < .01). The contrast noise ratio of knowledge based IMR images was significantly higher than those of FBP and hybrid IR images (knowledge based IMR: 29.1 +/- 5.4; FBP: 4.6 +/- 1.3; hybrid IR: 13.1 +/- 3.5, respectively) (P < .01). There were moderate correlations between image noise and body mass index in FBP (r = 0.57, P < .01) and hybrid IR techniques (r = 0.42, P < .01); however, these correlations were weak in knowledge-based IMR (r = 0.27, P < .01). Conclusion: Compared to FBP and hybrid IR, the knowledge-based IMR offers significant noise reduction and improvement in image quality in submillisievert radiation dose cardiac CT.
引用
收藏
页码:1393 / 1401
页数:9
相关论文
共 50 条
  • [21] Radiation dose and diagnostic image quality associated with iterative reconstruction in coronary CT angiography: A systematic review
    Abdullah, Kamarul Amin
    McEntee, Mark F.
    Reed, Warren
    Kench, Peter L.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2016, 60 (04) : 459 - 468
  • [22] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Eun-Ah Park
    Whal Lee
    Kwang Woo Kim
    Kwang Gi Kim
    Allmendinger Thomas
    Jin Wook Chung
    Jae Hyung Park
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1775 - 1786
  • [23] Accuracy of Coronary CT Angiography Using a Submillisievert Fraction of Radiation Exposure Comparison With Invasive Coronary Angiography
    Stehli, Julia
    Fuchs, Tobias A.
    Bull, Sacha
    Clerc, Olivier F.
    Possner, Mathias
    Buechel, Ronny R.
    Gaemperli, Oliver
    Kaufmann, Philipp A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (08) : 772 - 780
  • [24] Evaluation of image quality and radiation dose saving comparing knowledge model–based iterative reconstruction on 80-kV CT pulmonary angiography (CTPA) with hybrid iterative reconstruction on 100-kV CT
    Davide Ippolito
    Andrea De Vito
    Cammillo Talei Franzesi
    Luca Riva
    Anna Pecorelli
    Rocco Corso
    Andrea Crespi
    Sandro Sironi
    Emergency Radiology, 2019, 26 : 145 - 153
  • [25] Knowledge-based iterative model reconstruction (IMR) algorithm in ultralow-dose CT for evaluation of urolithiasis: evaluation of radiation dose reduction, image quality, and diagnostic performance
    Park, Sung Bin
    Kim, Yang Soo
    Lee, Jong Beum
    Park, Hyun Jeong
    ABDOMINAL IMAGING, 2015, 40 (08): : 3137 - 3146
  • [26] Knowledge-based iterative model reconstruction (IMR) algorithm in ultralow-dose CT for evaluation of urolithiasis: evaluation of radiation dose reduction, image quality, and diagnostic performance
    Sung Bin Park
    Yang Soo Kim
    Jong Beum Lee
    Hyun Jeong Park
    Abdominal Imaging, 2015, 40 : 3137 - 3146
  • [27] Estimated Radiation Dose Reduction Using Adaptive Statistical Iterative Reconstruction in Coronary CT Angiography: The ERASIR Study
    Leipsic, Jonathon
    LaBounty, Troy M.
    Heilbron, Brett
    Min, James K.
    Mancini, G. B. John
    Lin, Fay Y.
    Taylor, Carolyn
    Dunning, Allison
    Earls, James P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 655 - 660
  • [28] Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiography
    Sonja Gordic
    Lotus Desbiolles
    Martin Sedlmair
    Robert Manka
    André Plass
    Bernhard Schmidt
    Daniela B. Husarik
    Francesco Maisano
    Simon Wildermuth
    Hatem Alkadhi
    Sebastian Leschka
    European Radiology, 2016, 26 : 459 - 468
  • [29] Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiography
    Gordic, Sonja
    Desbiolles, Lotus
    Sedlmair, Martin
    Manka, Robert
    Plass, Andre
    Schmidt, Bernhard
    Husarik, Daniela B.
    Maisano, Francesco
    Wildermuth, Simon
    Alkadhi, Hatem
    Leschka, Sebastian
    EUROPEAN RADIOLOGY, 2016, 26 (02) : 459 - 468
  • [30] Computational and human observer image quality evaluation of low dose, knowledge-based CT iterative reconstruction
    Eck, Brendan L.
    Fahmi, Rachid
    Brown, Kevin M.
    Zabic, Stanislav
    Raihani, Nilgoun
    Miao, Jun
    Wilson, David L.
    MEDICAL PHYSICS, 2015, 42 (10) : 6098 - 6111