Validity and reliability of the T-Scan®III for measuring force under laboratory conditions

被引:45
|
作者
Cerna, M. [1 ]
Ferreira, R. [2 ]
Zaror, C. [2 ]
Navarro, P. [3 ]
Sandoval, P. [2 ]
机构
[1] Univ La Frontera, Fac Sci & Engn, Dept Phys Sci, Temuco, Chile
[2] Univ La Frontera, Fac Dent, Dept Pediat Dent & Orthodont, Destristry Program, Temuco, Chile
[3] Univ La Frontera, Fac Dent, Temuco, Chile
关键词
validity; reliability; T-Scan((R))III; bite force; bite registration; dental occlusion;
D O I
10.1111/joor.12284
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Although measuring bite force is an important indicator of the health of the masticatory system, few commercially available transducers have been validated for routine clinical use. T-Scan((R))III Occlusal Analysis System allows to record the bite force distribution, indicating its relative intensity and occlusal timing. Nevertheless, even fewer studies have evaluated the validity and reliability of the latest generation of the T-Scan((R)) occlusal analysis system. To determine the validity and reliability of the T-Scan((R))III system when measuring total absolute bite force under laboratory conditions. Known forces were applied to 18 T-Scan((R))III sensors, which were classified into two groups differentiated by their production series. Both Lin's concordance correlation coefficient (CCC) and the intra-class correlation coefficient (ICC) were used to assess the system's reliability and validity. Considering all the sensors studied, a substantial level (Lin's CCC 0969) and a very good level of reliability (CCI 0994) were obtained. When evaluating the validity of the system, a poor (Lin's CCC 0530) and moderate (ICC 0693) agreement were also obtained. The main factor that negatively influenced the validity of the T-Scan((R))III under these study conditions was the significant difference in the behaviour of the two sensor groups. The T-Scan((R))III showed a high degree of reliability when used to perform consecutive measurements. However, the system showed an insufficient degree of validity for measuring absolute force when estimating total occlusal force under laboratory conditions.
引用
收藏
页码:544 / 551
页数:8
相关论文
共 50 条
  • [41] Stability of DTPA and iron(III)-DTPA under laboratory ecotoxicological conditions
    Van Dam, RA
    Porter, NA
    Ahokas, JT
    Holdway, DA
    WATER RESEARCH, 1999, 33 (05) : 1320 - 1324
  • [42] Evaluation of the Accuracy and Reliability of a Tubeless Insulin Infusion System Under Laboratory Conditions
    Mende, Jochen
    Eichenlaub, Manuel
    Waldenmaier, Delia
    Haug, Cornelia
    Freckmann, Guido
    Ziegler, Ralph
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2022, 16 (03): : 788 - 789
  • [43] Measuring Vertical Distribution and Dynamic Development of Sediment Infiltration under Laboratory Conditions
    Mayar, M. A.
    Haun, S.
    Schmid, G.
    Wieprecht, S.
    Noack, M.
    JOURNAL OF HYDRAULIC ENGINEERING, 2022, 148 (06)
  • [44] VALIDITY AND RELIABILITY OF "STEP COUNT" FUNCTION OF THE ACTITRAINER ACTIVITY MONITOR UNDER CONTROLLED CONDITIONS
    Neuls, Filip
    ACTA GYMNICA, 2008, 38 (02) : 55 - 64
  • [45] Laboratory reliability and validity for measuring psychosine concentration and GALC enzyme activity for use in newborn screening for Krabbe disease
    Jalal, Kabir K.
    Langan, Thomas J.
    Orsini, Joseph
    Gelb, Michael
    Matern, Dieter
    Barczykowski, Amy L.
    Escolar, Maria
    Carter, Randy
    MOLECULAR GENETICS AND METABOLISM, 2018, 123 (02) : S69 - S70
  • [46] Reliability and Validity of the Strain Gauge "GSTRENGTH" for Measuring Peak Force in the Isometric Belt Squat at Different Joint Angles
    Varela-Olalla, Daniel
    Balsalobre-Fernandez, Carlos
    Romero-Moraleda, Blanca
    Jimenez-Saiz, Sergio L.
    SENSORS, 2024, 24 (10)
  • [47] Validity and Intrarater Reliability of the FysioMeter-Measuring Eccentric Knee Flexor Force During the Nordic Hamstring Exercise
    Stove, Morten Pallisgaard
    Kristensen, Mathias Kringelholt
    Nielsen, Jonas
    Madsen, Lea Dyhrberg
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2025,
  • [48] A modified method for measuring root iron reductase activity under normal laboratory conditions
    Zheng, SJ
    He, YF
    Tang, CX
    Masaoka, Y
    PEDOSPHERE, 2005, 15 (03) : 363 - 368
  • [49] A Modified Method for Measuring Root Iron Reductase Activity Under Normal Laboratory Conditions
    Y. MASAOKA
    Pedosphere, 2005, (03) : 363 - 368
  • [50] Measuring the acoustic backscattering form function from a spherical target under laboratory conditions
    Wang, Lian Sheng
    Foote, Kenneth G.
    Robinson, Stephen P.
    Humphrey, Victor F.
    2022 OCEANS HAMPTON ROADS, 2022,