Validity and reliability of the T-Scan®III for measuring force under laboratory conditions

被引:45
|
作者
Cerna, M. [1 ]
Ferreira, R. [2 ]
Zaror, C. [2 ]
Navarro, P. [3 ]
Sandoval, P. [2 ]
机构
[1] Univ La Frontera, Fac Sci & Engn, Dept Phys Sci, Temuco, Chile
[2] Univ La Frontera, Fac Dent, Dept Pediat Dent & Orthodont, Destristry Program, Temuco, Chile
[3] Univ La Frontera, Fac Dent, Temuco, Chile
关键词
validity; reliability; T-Scan((R))III; bite force; bite registration; dental occlusion;
D O I
10.1111/joor.12284
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Although measuring bite force is an important indicator of the health of the masticatory system, few commercially available transducers have been validated for routine clinical use. T-Scan((R))III Occlusal Analysis System allows to record the bite force distribution, indicating its relative intensity and occlusal timing. Nevertheless, even fewer studies have evaluated the validity and reliability of the latest generation of the T-Scan((R)) occlusal analysis system. To determine the validity and reliability of the T-Scan((R))III system when measuring total absolute bite force under laboratory conditions. Known forces were applied to 18 T-Scan((R))III sensors, which were classified into two groups differentiated by their production series. Both Lin's concordance correlation coefficient (CCC) and the intra-class correlation coefficient (ICC) were used to assess the system's reliability and validity. Considering all the sensors studied, a substantial level (Lin's CCC 0969) and a very good level of reliability (CCI 0994) were obtained. When evaluating the validity of the system, a poor (Lin's CCC 0530) and moderate (ICC 0693) agreement were also obtained. The main factor that negatively influenced the validity of the T-Scan((R))III under these study conditions was the significant difference in the behaviour of the two sensor groups. The T-Scan((R))III showed a high degree of reliability when used to perform consecutive measurements. However, the system showed an insufficient degree of validity for measuring absolute force when estimating total occlusal force under laboratory conditions.
引用
收藏
页码:544 / 551
页数:8
相关论文
共 50 条
  • [1] Reliability and Validity of T-scan and 3D Intraoral Scanning for Measuring the Occlusal Contact Area
    Ayuso-Montero, Raul
    Mariano-Hernandez, Yumaysla
    Khoury-Ribas, Laura
    Rovira-Lastra, Bernat
    Willaert, Eva
    Martinez-Gomis, Jordi
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2020, 29 (01): : 19 - 25
  • [2] SENSITIVITY AND RELIABILITY OF THE T-SCAN FOR OCCLUSAL ANALYSIS
    HSU, ML
    GALLO, LM
    PALLA, S
    JOURNAL OF DENTAL RESEARCH, 1990, 69 : 335 - 335
  • [3] In vitro evaluation of T-Scan®III through study of the sensels
    Cerna, Manuel
    Ferreira, Roxana
    Zaror, Carlos
    Navarro, Pablo
    Sandoval, Paulo
    CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE, 2015, 33 (04): : 300 - 306
  • [4] Application in the analysis of the occlusal force of free-end missing tooth implant restoration with T-SCAN III
    Wu, Ming-Le
    Lai, Peng-Yu
    Cheong, Fan
    Zhou, Wen-Cheng
    Xu, Sang-Hui
    Li, Hui
    Shen, Shan
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [5] OCCLUSION AND ARTICULATION IN BRUXISM AND BRUXOMANIA INVESTIGATED WITH THE SYSTEM T-SCAN III
    Dimova, Mariana
    JOURNAL OF IMAB, 2014, 20 (05): : 655 - 660
  • [6] The occlusal imaging and analysis system by T-scan III in tinnitus patients
    Di Berardino, Federica
    Filipponi, Eliana
    Schiappadori, Massimo
    Forti, Stella
    Zanetti, Diego
    Cesarani, Antonio
    BIOMEDICAL JOURNAL, 2016, 39 (02) : 139 - 144
  • [7] Reference values and reliability of occlusal force distribution and occlusal time measured by the T-Scan system in adults with healthy dentition
    Rubio-Ferrer, Gemma
    Rovira-Lastra, Bernat
    Khoury-Ribas, Laura
    Flores-Orozco, Elan Ignacio
    Ayuso-Montero, Raul
    Martinez-Gomis, Jordi
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (06): : 558 - 564
  • [8] ADJUSTING OF A STABILIZATION SPLINT BY THE USE OF T-SCAN III - BIOEMG INTEGRATED SYSTEM
    Popsor, S.
    Szasz, O.
    Soaita, Liana Claudia
    Hantoiu, Liana Georgiana
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2010, 2 (02): : 14 - 20
  • [9] Comparison of excursive occlusal force parameters in post-orthodontic and non-orthodontic subjects using T-Scan® III
    Qadeer, Sarah
    Abbas, Ahmed A.
    Sarinnaphakorn, Lertrit
    Kerstein, Robert B.
    CRANIO-THE JOURNAL OF CRANIOMANDIBULAR & SLEEP PRACTICE, 2018, 36 (01): : 11 - 18
  • [10] Use of T-Scan III in analyzing occlusal changes in molar fixed denture placement
    Chan, Hei
    Alimujiang, Adili
    Fong, Sin Iok
    Wu, Ming-Le
    Liang, Ran
    Lai, Peng-Yu
    Wei, Hui-Wen
    Shen, Shan
    BMC ORAL HEALTH, 2024, 24 (01)