The Effect of Body Mass Index on Fluoroscopic Time and Radiation Dose During Sacroiliac Joint Injections

被引:18
|
作者
Cushman, Daniel [1 ]
Flis, Alexandra [1 ]
Jensen, Ben [1 ]
McCormick, Zachary [2 ]
机构
[1] Univ Utah, Div Phys Med & Rehabil, 590 Wakara Way, Salt Lake City, UT 84108 USA
[2] Northwestern Univ, Rehabil Inst Chicago, Dept Phys Med & Rehabil, Feinberg Sch Med, Chicago, IL 60611 USA
关键词
EXPOSURE; OBESITY; SPINE; PAIN; OVERWEIGHT; RADIOLOGY; MORTALITY; IMPACT; WOMEN; RISK;
D O I
10.1016/j.pmrj.2015.11.008
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Sacroiliac joint (SIJ) injections are commonly performed under fluoroscopic guidance. Radiation exposure to patients and providers has not been comprehensively studied, particularly the effect of body mass index (BMI). Objective: To identify whether patients with a larger BMI require longer fluoroscopy time or a larger radiation dose during performance of an SIJ injection. Design: Retrospective study of an academic institution database. Setting: Academic outpatient musculoskeletal clinic. Patients: All patients who underwent SIJ injections during a 10-year period. Main Outcome Measurements: Machine-reported fluoroscopic time and machine-reported radiation dose. A Bonferroni correction was implemented with P < .01 as statistically significant. Results: A total of 453 SIJ injections were performed in 359 patients. No statistically significant differences in fluoroscopy time were found between patients with BMI scores identified as normal, overweight, and obese (P = .054). However, the radiation doses were significantly greater for patients with higher BMI scores (chi(2) [2, n = 441] = 62.4, P < .001); the median (interquartile range) doses were 1210 (839), 1671 (1240), and 2090 (2170) mGy-cm(2) for normal weight, overweight, and obese patients, respectively. Although longer needles were used more often in obese patients (chi(2) [2, n = 452] = 31.5, P < .001), fluoroscopy time was not associated with needle length (P = .162). No relationships were identified between fluoroscopy time and first-time (as opposed to repeat) injection (P = .123), trainee involvement (chi(2) [1, n = 698] = 3.9, P = .049), or age (P = .337). Conclusions: Patients with an elevated BMI score who are undergoing SIJ injection receive an increased radiation dose despite equivalent fluoroscopic time. This finding suggests that the increased dose is likely due to x-ray output from the fluoroscope traversing a greater tissue mass, as opposed to the physician requiring more fluoroscopic images for proper needle placement. Fortunately, the increased radiation dose delivered to patients with a larger BMI score likely has negligible effects.
引用
收藏
页码:767 / 772
页数:6
相关论文
共 50 条
  • [41] The Effect of Body Mass Index on Ventilatory Parameters During Exercise
    Monterroso, Carissa
    Cruz, Lucas
    Datta, Debapriya
    CHEST, 2016, 150 (04) : 1114A - 1114A
  • [42] Effect of periarticular and intraarticular lidocaine injections for sacroiliac joint pain: prospective comparative study
    Murakami, Eiichi
    Tanaka, Yasuhisa
    Aizawa, Toshimi
    Ishizuka, Masato
    Kokubun, Shoichi
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2007, 12 (03) : 274 - 280
  • [43] Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures
    Chida, K
    Saito, H
    Otani, H
    Kohzuki, M
    Takahashi, S
    Yamada, S
    Shirato, K
    Zuguchi, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (03) : 774 - 778
  • [44] Variation of fluoroscopic radiation dose during endourological procedures for renal stones
    Shah, C.
    INTERNATIONAL JOURNAL OF UROLOGY, 2019, 26 : 72 - 72
  • [45] Energy expenditure during leisure time and body mass index in Spain
    Martín-Almendros, S
    Martínez-González, MA
    De Irala-Estévez, J
    Gibney, MJ
    Kearney, J
    Martínez, JA
    JOURNAL OF PHYSIOLOGY AND BIOCHEMISTRY, 2000, 56 (02) : 131 - 132
  • [46] Fluoroscopically guided transforaminal epidural steroid injections at a quaternary-care teaching institution: effect of trainee involvement and patient body mass index on fluoroscopy time and patient dose
    Tiegs-Heiden, C. A.
    Murthy, N. S.
    Geske, J. R.
    Diehn, F. E.
    Schueler, B. A.
    Wald, J. T.
    Kaufmann, T. J.
    Lehman, V. T.
    Carr, C. M.
    Amrami, K. K.
    Morris, J. M.
    Thielen, K. R.
    Maus, T. P.
    CLINICAL RADIOLOGY, 2016, 71 (01) : E16 - E20
  • [47] Preliminary analysis of interaction of the fat fraction in the sacroiliac joint among sex, age, and body mass index in a normal Chinese population
    Ning, Qiuping
    Fan, Tiebing
    Tang, Jinyang
    Han, Shuhua
    Wang, Wensheng
    Ren, Hua
    Wang, Haiyi
    Ye, Huiyi
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2020, 48 (07)
  • [48] Radiation Exposure to the Sacroiliac Joint From Low-Dose CT Compared With Radiography
    Chahal, Baljot S.
    Kwan, Alexander L. C.
    Dhillon, Sukhvinder S.
    Olubaniyi, Babajide O.
    Jhiangri, Gian S.
    Neilson, Matthew M.
    Lambert, Robert G. W.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (05) : 1058 - 1062
  • [49] Effect of Body Mass Index on Procedure Time, Amount of Sedation, and Prep Quality During Screening Colonoscopy
    Austin, Gregory
    Czwornog, Jennifer
    GASTROINTESTINAL ENDOSCOPY, 2012, 75 (04) : 504 - 504
  • [50] Technique and radiation dose of conventional X-rays and computed tomography of the sacroiliac joint
    Jurik, AG
    RADIOLOGE, 2004, 44 (03): : 229 - 233