The Effect of Body Mass Index on Fluoroscopic Time and Radiation Dose During Sacroiliac Joint Injections

被引:18
|
作者
Cushman, Daniel [1 ]
Flis, Alexandra [1 ]
Jensen, Ben [1 ]
McCormick, Zachary [2 ]
机构
[1] Univ Utah, Div Phys Med & Rehabil, 590 Wakara Way, Salt Lake City, UT 84108 USA
[2] Northwestern Univ, Rehabil Inst Chicago, Dept Phys Med & Rehabil, Feinberg Sch Med, Chicago, IL 60611 USA
关键词
EXPOSURE; OBESITY; SPINE; PAIN; OVERWEIGHT; RADIOLOGY; MORTALITY; IMPACT; WOMEN; RISK;
D O I
10.1016/j.pmrj.2015.11.008
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Sacroiliac joint (SIJ) injections are commonly performed under fluoroscopic guidance. Radiation exposure to patients and providers has not been comprehensively studied, particularly the effect of body mass index (BMI). Objective: To identify whether patients with a larger BMI require longer fluoroscopy time or a larger radiation dose during performance of an SIJ injection. Design: Retrospective study of an academic institution database. Setting: Academic outpatient musculoskeletal clinic. Patients: All patients who underwent SIJ injections during a 10-year period. Main Outcome Measurements: Machine-reported fluoroscopic time and machine-reported radiation dose. A Bonferroni correction was implemented with P < .01 as statistically significant. Results: A total of 453 SIJ injections were performed in 359 patients. No statistically significant differences in fluoroscopy time were found between patients with BMI scores identified as normal, overweight, and obese (P = .054). However, the radiation doses were significantly greater for patients with higher BMI scores (chi(2) [2, n = 441] = 62.4, P < .001); the median (interquartile range) doses were 1210 (839), 1671 (1240), and 2090 (2170) mGy-cm(2) for normal weight, overweight, and obese patients, respectively. Although longer needles were used more often in obese patients (chi(2) [2, n = 452] = 31.5, P < .001), fluoroscopy time was not associated with needle length (P = .162). No relationships were identified between fluoroscopy time and first-time (as opposed to repeat) injection (P = .123), trainee involvement (chi(2) [1, n = 698] = 3.9, P = .049), or age (P = .337). Conclusions: Patients with an elevated BMI score who are undergoing SIJ injection receive an increased radiation dose despite equivalent fluoroscopic time. This finding suggests that the increased dose is likely due to x-ray output from the fluoroscope traversing a greater tissue mass, as opposed to the physician requiring more fluoroscopic images for proper needle placement. Fortunately, the increased radiation dose delivered to patients with a larger BMI score likely has negligible effects.
引用
收藏
页码:767 / 772
页数:6
相关论文
共 50 条
  • [31] Axillary Radiation Dose to the Interventionalist During Fluoroscopic Procedures
    Baker, J.
    Demertzis, J.
    Lonsford, C.
    Wessell, D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [32] Analysis of Time Course and Dose Effect From Metformin on Body Mass Index in Children and Adolescents
    Wang, Dong-Dong
    Mao, Yi-Zhen
    He, Su-Mei
    Chen, Xiao
    FRONTIERS IN PHARMACOLOGY, 2021, 12
  • [33] EFFECT OF IMAGING TIME ON THE VALUES OF THE SACROILIAC INDEX
    DODIG, D
    DOMLJAN, Z
    POPOVIC, S
    SIMONOVIC, I
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1988, 14 (9-10): : 504 - 506
  • [34] Calculation of FDG Dose Based on Body Mass Index to Reduce Radiation Exposure
    Jurau, C.
    Jain, N.
    Kumar, A.
    Muzik, O.
    Dauod, M.
    Janabi, M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [35] An Analysis of the Factors Influencing Radiation Dose and Fluoroscopic Time During Renal Artery Stent Placement
    McBride, J.
    Schueler, B.
    Oderich, G.
    Misra, S.
    VASCULAR AND ENDOVASCULAR SURGERY, 2013, 47 (06) : 462 - 466
  • [36] Radiation Dose Exposure for Lumbar Transforaminal Epidural Steroid Injections and Facet Joint Blocks Under CT vs. Fluoroscopic Guidance
    Maino, Paolo
    Presilla, Stefano
    Franzone, Paola A. Colli
    van Kuijk, Sander M. J.
    Perez, Roberto S. G. M.
    Koetsier, Eva
    PAIN PRACTICE, 2018, 18 (06) : 798 - 804
  • [37] Operator Radiation Dose Reduction During Fluoroscopic Interventional Procedures
    Nachiappan, Arun C.
    Horn, Gag L.
    Spann, Stephanie C.
    Mayo, Ray C.
    Wynne, David M.
    Archer, Benjamin R.
    Whigham, Cliff J.
    Hancock, John A.
    JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2015, 12 (05) : 527 - 530
  • [38] The effect of increased body mass index on patient dose in paediatric radiography
    Ladia, Arsenoi P.
    Skiadopoulos, Spyros G.
    Karahaliou, Anna N.
    Messaris, Gerasimos A. T.
    Delis, Harry B.
    Panayiotakis, George S.
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (10) : 1689 - 1694
  • [39] Evaluation of Dose Modulation Software Through the Assessment of Body Mass Index, Radiation Dose and Image Noise
    Daignault, Cory P.
    Zhang, Jie
    Guo, Hongfei
    Roy, David W.
    Froelich, Jerry F.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2013, 37 (04) : 547 - 550
  • [40] The relationship between body mass index and fluoroscopy time during intra-articular hip injections: a multicenter cohort study
    Bhave, M.
    McCormick, Z.
    Lee, D.
    Scholten, P.
    Chu, S.
    Babu, A.
    Caldwell, M.
    Ziegler, C.
    Ashraf, H.
    Cara, J.
    Clark, R.
    McCormick, K.
    Gross, C.
    Ross, B.
    Press, J.
    Smuck, M.
    Cushman, D.
    Walega, D.
    JOURNAL OF PAIN, 2016, 17 (04): : S92 - S92