The Effect of Body Mass Index on Fluoroscopic Time and Radiation Dose During Sacroiliac Joint Injections

被引:18
|
作者
Cushman, Daniel [1 ]
Flis, Alexandra [1 ]
Jensen, Ben [1 ]
McCormick, Zachary [2 ]
机构
[1] Univ Utah, Div Phys Med & Rehabil, 590 Wakara Way, Salt Lake City, UT 84108 USA
[2] Northwestern Univ, Rehabil Inst Chicago, Dept Phys Med & Rehabil, Feinberg Sch Med, Chicago, IL 60611 USA
关键词
EXPOSURE; OBESITY; SPINE; PAIN; OVERWEIGHT; RADIOLOGY; MORTALITY; IMPACT; WOMEN; RISK;
D O I
10.1016/j.pmrj.2015.11.008
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Sacroiliac joint (SIJ) injections are commonly performed under fluoroscopic guidance. Radiation exposure to patients and providers has not been comprehensively studied, particularly the effect of body mass index (BMI). Objective: To identify whether patients with a larger BMI require longer fluoroscopy time or a larger radiation dose during performance of an SIJ injection. Design: Retrospective study of an academic institution database. Setting: Academic outpatient musculoskeletal clinic. Patients: All patients who underwent SIJ injections during a 10-year period. Main Outcome Measurements: Machine-reported fluoroscopic time and machine-reported radiation dose. A Bonferroni correction was implemented with P < .01 as statistically significant. Results: A total of 453 SIJ injections were performed in 359 patients. No statistically significant differences in fluoroscopy time were found between patients with BMI scores identified as normal, overweight, and obese (P = .054). However, the radiation doses were significantly greater for patients with higher BMI scores (chi(2) [2, n = 441] = 62.4, P < .001); the median (interquartile range) doses were 1210 (839), 1671 (1240), and 2090 (2170) mGy-cm(2) for normal weight, overweight, and obese patients, respectively. Although longer needles were used more often in obese patients (chi(2) [2, n = 452] = 31.5, P < .001), fluoroscopy time was not associated with needle length (P = .162). No relationships were identified between fluoroscopy time and first-time (as opposed to repeat) injection (P = .123), trainee involvement (chi(2) [1, n = 698] = 3.9, P = .049), or age (P = .337). Conclusions: Patients with an elevated BMI score who are undergoing SIJ injection receive an increased radiation dose despite equivalent fluoroscopic time. This finding suggests that the increased dose is likely due to x-ray output from the fluoroscope traversing a greater tissue mass, as opposed to the physician requiring more fluoroscopic images for proper needle placement. Fortunately, the increased radiation dose delivered to patients with a larger BMI score likely has negligible effects.
引用
收藏
页码:767 / 772
页数:6
相关论文
共 50 条
  • [1] Impact of flow pattern, body mass index, and age on intraprocedural fluoroscopic time and radiation dose during sacroiliac joint injections
    Tiegs-Heiden, Christin A.
    Murthy, Naveen S.
    Geske, Jennifer R.
    Diehn, Felix E.
    Lehman, Vance T.
    Liebo, Greta B.
    Verdoorn, Jared T.
    Carr, Carrie M.
    McKenzie, Gavin A.
    NEURORADIOLOGY JOURNAL, 2021, 34 (05): : 428 - 434
  • [2] The Effect of Body Mass Index on Fluoroscopic Time and Radiation Dose During Intra-articular Hip Injections
    Cushman, Daniel M.
    Mattie, Ryan
    Clements, Nathan D.
    McCormick, Zachary L.
    PM&R, 2016, 8 (09) : 876 - 882
  • [3] The effect of body mass index on fluoroscopic time and radiation dose during lumbar transforaminal epidural steroid injections
    Cushman, Daniel
    Mattie, Ryan
    Curtis, Bradley
    Flis, Alexandra
    McCormick, Zachary L.
    SPINE JOURNAL, 2016, 16 (07): : 876 - 883
  • [4] The effect of body mass index on fluoroscopy time and radiation dose in intra-articular glenohumeral joint injections
    Mattie, Ryan
    McCormick, Zachary L.
    Fogg, Benjamin
    Cushman, Daniel M.
    CLINICAL IMAGING, 2017, 42 : 19 - 24
  • [5] The Influence of Body Mass Index on Radiation Dose and Exposure Time in Fluoroscopic Guided Hip Injections - A Comparative Analysis of Two Approaches
    Sidharthan, Sujith
    Maliyappa, Chandrashekara
    Bhinda, Hans
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2023, 11 (09): : 577 - 581
  • [6] OUTCOMES OF FLUOROSCOPIC SACROILIAC JOINT INJECTIONS (PATIENTS VIEWS)
    Al-Rubae, R.
    Chattopadhyay, C.
    ANNALS OF THE RHEUMATIC DISEASES, 2014, 73 : 1090 - 1091
  • [7] The effect of body mass index and Departmenth of epidural space on fluoroscopic time and radiation dose during transforaminal nerve block injection, a retrospective observational study
    Galbraith, A. S.
    Shafqat, A.
    Devitt, A.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2017, 186 : S156 - S156
  • [8] Is There a Relationship Between Body Mass Index and Fluoroscopy Time During Sacroiliac Joint Injection? A Multicenter Cohort Study
    McCormick, Zachary L.
    Cushman, Daniel
    Lee, David T.
    Scholten, Paul
    Chu, Samuel K.
    Babu, Ashwin N.
    Caldwell, Mary
    Ziegler, Craig
    Ashraf, Humaira
    Sundar, Bindu
    Clark, Ryan
    Gross, Claire
    Cara, Jeffrey
    McCormick, Kristen
    Ross, Brendon
    Smith, Clark C.
    Press, Joel
    Smuck, Matthew
    Walega, David R.
    PAIN MEDICINE, 2016, 17 (07) : 1241 - 1248
  • [9] Age, body mass index, and gender differences in sacroiliac joint pathology
    Irwin, Robert W.
    Watson, Todd
    Minick, Ryan P.
    Ambrosius, Walter T.
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2007, 86 (01) : 37 - 44
  • [10] Intraarticular Sacroiliac Joint Injection Under Computed Tomography Fluoroscopic Guidance: A Technical Note to Reduce Procedural Time and Radiation Dose
    Nam Chull Paik
    CardioVascular and Interventional Radiology, 2016, 39 : 1057 - 1060