The accuracy of digital templating in uncemented total hip arthroplasty

被引:55
|
作者
Holzer, Lukas A. [1 ,2 ]
Scholler, Georg [1 ,3 ]
Wagner, Stefan [4 ]
Friesenbichler, Joerg [1 ]
Maurer-Ertl, Werner [1 ]
Leithner, Andreas [1 ]
机构
[1] Med Univ Graz, Dept Orthopaed & Traumatol, Auenbruggerpl 5, A-8036 Graz, Austria
[2] AUVA Trauma Ctr Klagenfurt, Klagenfurt Am Worthersee, Austria
[3] Karl Landsteiner Univ Hlth Sci, Dept Traumatol, Krems, Austria
[4] Johannes Keppler Univ Linz, Dept Sociol, Linz, Austria
关键词
Total hip arthroplasty; Digital templating; X-rays; Experience; Obesity; HEAD SIZE; REPLACEMENT; DISLOCATION; PRECISION; ANALOG;
D O I
10.1007/s00402-018-3080-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Preoperative planning is an essential part of total hip arthroplasty (THA). It facilitates the surgical procedure, helps to provide the correct implant size and aims at restoring biomechanical conditions. In recent times, surgeons rely more and more on digital templating techniques. Although the conversion to picture archiving and communication system had many positive effects, there are still problems that have to be taken into consideration. Objectives The core objective was to evaluate the impact of the planners' experience on the accuracy of predicting component size in digital preoperative templating of THA. In addition, the influence of overweight and obesity (according to WHO-criteria), patient's sex and component design on the accuracy of preoperative planning have been analysed. Materials and methods The retrospective study included 632 consecutive patients who had primary uncemented THA. Digital templating was done using "syngo-EndoMap" software by Siemens Medical Solutions AG. Mann-Whitney U test and Kruskal-Wallis test have been used for statistical analysis. The accuracy of predicting component size has been evaluated by comparing preoperative planned sizes with implanted sizes as documented by the surgeons. The planner's experience was tested by comparing the reliability of preoperative planning done by senior surgeons or residents. The influence of BMI on predicting component size has been tested by comparing the accuracy of digital templating between different groups of BMI according to WHO-criteria. The same procedure has been done for evaluating the impact of patients sex and component design. Results The implant size was predicted exactly in 42% for the femoral and in 37% for the acetabular component. 87% of the femoral components and 78% of the acetabular cups were accurate within one size. Digital templating of femoral implant size was significantly more reliable when done by a senior surgeon. No difference was found for the acetabular component sizes. The BMI also had an impact on estimating the correct femoral implant size. In overweight patients, planning was significantly more inaccurate than normal weight people. Differences were seen in obese patients. However, these were not significant. Accuracy of acetabular components was not affected. The design of the prostheses and the patient's sex had no influence on predicting component size. Conclusions Inexperience and overweight are factors that correlate with inaccuracy of preoperative digital templating in femoral components, whereas acetabular components seem to be independent of these factors.
引用
收藏
页码:263 / 268
页数:6
相关论文
共 50 条
  • [41] The accuracy and inter-observer reliability of acetate templating in total hip arthroplasty
    R Kearney
    J O'Byrne
    A Shaikh
    BMC Proceedings, 6 (Suppl 4)
  • [42] The accuracy and inter-observer reliability of acetate templating in total hip arthroplasty
    R. Kearney
    A. H. Shaikh
    J. M. O’Byrne
    Irish Journal of Medical Science, 2013, 182 : 409 - 414
  • [43] Digital templating in total knee and hip replacement: an analysis of planning accuracy
    Bettina Kniesel
    Lukas Konstantinidis
    Anja Hirschmüller
    Norbert Südkamp
    Peter Helwig
    International Orthopaedics, 2014, 38 : 733 - 739
  • [44] Digital templating in total knee and hip replacement: an analysis of planning accuracy
    Kniesel, Bettina
    Konstantinidis, Lukas
    Hirschmueller, Anja
    Suedkamp, Norbert
    Helwig, Peter
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (04) : 733 - 739
  • [45] The accuracy and reliability of preoperative digital 2D templating in prosthesis size prediction in uncemented versus cemented total hip arthroplasty: a systematic review and meta-analysis
    Smith, Joshua B. V.
    Bishi, Habeeb
    Wang, Chao
    Asopa, Vipin
    Field, Richard E.
    Sochart, David H.
    EFORT OPEN REVIEWS, 2021, 6 (11) : 1020 - 1039
  • [46] A Comparison of Acetate vs Digital Templating for Preoperative Planning of Total Hip Arthroplasty
    Iorio, Richard
    Siegel, Jodi
    Specht, Lawrence M.
    Tilzey, John F.
    Hartman, Audrey
    Healy, William L.
    JOURNAL OF ARTHROPLASTY, 2009, 24 (02): : 175 - 179
  • [47] Total Hip Arthroplasty Digital Templating: Size Predicting Ability and Interobserver Variability
    Montiel, Veronica
    Troncoso, Santiago
    Valenti-Azcarate, Andres
    Valenti-Nin, Juan Ramon
    Lamo-Espinosa, Jose Maria
    INDIAN JOURNAL OF ORTHOPAEDICS, 2020, 54 (06) : 840 - 847
  • [48] Digital templating facilitates accurate leg length correction in total hip arthroplasty
    Jassim, Shivan Sabah
    Ingham, Christopher
    Keeling, Matthew
    Wimhurst, James Anthony
    ACTA ORTHOPAEDICA BELGICA, 2012, 78 (03): : 344 - 349
  • [49] Total Hip Arthroplasty Digital Templating: Size Predicting Ability and Interobserver Variability
    Veronica Montiel
    Santiago Troncoso
    Andrés Valentí-Azcárate
    Juan Ramón Valentí-Nin
    Jose María Lamo-Espinosa
    Indian Journal of Orthopaedics, 2020, 54 : 840 - 847
  • [50] Digital versus conventional templating techniques in preoperative planning for total hip arthroplasty
    Kosashvili, Yona
    Shasha, Nadav
    Olschewski, Eli
    Safir, Oleg
    White, Larry
    Gross, Allan
    Backstein, David
    CANADIAN JOURNAL OF SURGERY, 2009, 52 (01) : 6 - 11