The accuracy of digital templating in uncemented total hip arthroplasty

被引:55
|
作者
Holzer, Lukas A. [1 ,2 ]
Scholler, Georg [1 ,3 ]
Wagner, Stefan [4 ]
Friesenbichler, Joerg [1 ]
Maurer-Ertl, Werner [1 ]
Leithner, Andreas [1 ]
机构
[1] Med Univ Graz, Dept Orthopaed & Traumatol, Auenbruggerpl 5, A-8036 Graz, Austria
[2] AUVA Trauma Ctr Klagenfurt, Klagenfurt Am Worthersee, Austria
[3] Karl Landsteiner Univ Hlth Sci, Dept Traumatol, Krems, Austria
[4] Johannes Keppler Univ Linz, Dept Sociol, Linz, Austria
关键词
Total hip arthroplasty; Digital templating; X-rays; Experience; Obesity; HEAD SIZE; REPLACEMENT; DISLOCATION; PRECISION; ANALOG;
D O I
10.1007/s00402-018-3080-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction Preoperative planning is an essential part of total hip arthroplasty (THA). It facilitates the surgical procedure, helps to provide the correct implant size and aims at restoring biomechanical conditions. In recent times, surgeons rely more and more on digital templating techniques. Although the conversion to picture archiving and communication system had many positive effects, there are still problems that have to be taken into consideration. Objectives The core objective was to evaluate the impact of the planners' experience on the accuracy of predicting component size in digital preoperative templating of THA. In addition, the influence of overweight and obesity (according to WHO-criteria), patient's sex and component design on the accuracy of preoperative planning have been analysed. Materials and methods The retrospective study included 632 consecutive patients who had primary uncemented THA. Digital templating was done using "syngo-EndoMap" software by Siemens Medical Solutions AG. Mann-Whitney U test and Kruskal-Wallis test have been used for statistical analysis. The accuracy of predicting component size has been evaluated by comparing preoperative planned sizes with implanted sizes as documented by the surgeons. The planner's experience was tested by comparing the reliability of preoperative planning done by senior surgeons or residents. The influence of BMI on predicting component size has been tested by comparing the accuracy of digital templating between different groups of BMI according to WHO-criteria. The same procedure has been done for evaluating the impact of patients sex and component design. Results The implant size was predicted exactly in 42% for the femoral and in 37% for the acetabular component. 87% of the femoral components and 78% of the acetabular cups were accurate within one size. Digital templating of femoral implant size was significantly more reliable when done by a senior surgeon. No difference was found for the acetabular component sizes. The BMI also had an impact on estimating the correct femoral implant size. In overweight patients, planning was significantly more inaccurate than normal weight people. Differences were seen in obese patients. However, these were not significant. Accuracy of acetabular components was not affected. The design of the prostheses and the patient's sex had no influence on predicting component size. Conclusions Inexperience and overweight are factors that correlate with inaccuracy of preoperative digital templating in femoral components, whereas acetabular components seem to be independent of these factors.
引用
收藏
页码:263 / 268
页数:6
相关论文
共 50 条
  • [21] Precision of preoperative digital templating in total hip arthroplasty
    Efe, Turgay
    El Zayat, Bilal Farouk
    Heyse, Thomas J.
    Timmesfeld, Nina
    Fuchs-Winkelmann, Susanne
    Schmitt, Jan
    ACTA ORTHOPAEDICA BELGICA, 2011, 77 (05): : 616 - 621
  • [22] Digital templating in total hip arthroplasty with the Mayo stem
    Christian Wedemeyer
    Henning Quitmann
    Jie Xu
    Hansjoerg Heep
    Marius von Knoch
    Guido Saxler
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 1023 - 1029
  • [23] Calibration Markers for Digital Templating in Total Hip Arthroplasty
    Boese, Christoph Kolja
    Lechler, Philipp
    Rose, Leonard
    Dargel, Jens
    Oppermann, Johannes
    Eysel, Peer
    Geiges, Hansjoerg
    Bredow, Jan
    PLOS ONE, 2015, 10 (07):
  • [24] THE ACCURACY OF DIGITAL TEMPLATING IN PRIMARY TOTAL HIP ARTHROPLASTY: A RETROSPECTIVE STUDY OF 125HIPS
    Sasaki, T.
    Kodama, T.
    OSTEOPOROSIS INTERNATIONAL, 2020, 31 (SUPPL 1) : S474 - S474
  • [25] Evaluation of the Accuracy and Use of X-Ray Markers in Digital Templating for Total Hip Arthroplasty
    Bayne, Christopher O.
    Krosin, Michael
    Barber, Thomas C.
    JOURNAL OF ARTHROPLASTY, 2009, 24 (03): : 407 - 413
  • [26] Digital templating in total hip arthroplasty in the NHS: ‘computer says no…’
    Luckshmana Jeyaseelan
    Jonathan Ward
    Kyriacos Eleftheriou
    J. Cobb
    European Journal of Orthopaedic Surgery & Traumatology, 2011, 21 : 397 - 399
  • [27] Calibration Marker Position in Digital Templating of Total Hip Arthroplasty
    Boese, Christoph K.
    Bredow, Jan
    Dargel, Jens
    Eysel, Peer
    Geiges, Hansjoerg
    Lechler, Philipp
    JOURNAL OF ARTHROPLASTY, 2016, 31 (04): : 883 - 887
  • [28] Uncemented total hip arthroplasty in the elderly
    Ch. Konstantoulakis
    G. Anastopoulos
    A. Papaeliou
    A. Tsoutsanis
    A. Asimakopoulos
    International Orthopaedics, 1999, 23 : 334 - 336
  • [29] Uncemented total hip arthroplasty in the elderly
    Konstantoulakis, C
    Anastopoulos, G
    Papaeliou, A
    Tsoutsanis, A
    Asimakopoulos, A
    INTERNATIONAL ORTHOPAEDICS, 1999, 23 (06) : 334 - 336
  • [30] Validity and reliability of preoperative templating in total hip arthroplasty using a digital templating system
    Bertz, Ari
    Indrekvam, Kari
    Ahmed, Mohamed
    Englund, Erling
    Sayed-Noor, Arkan S.
    SKELETAL RADIOLOGY, 2012, 41 (10) : 1245 - 1249