Poly(L-lysine)-g-poly(ethylene glycol) layers on metal oxide surfaces:: Surface-analytical characterization and resistance to serum and fibrinogen adsorption

被引:462
|
作者
Huang, NP
Michel, R
Voros, J
Textor, M
Hofer, R
Rossi, A
Elbert, DL
Hubbell, JA
Spencer, ND [1 ]
机构
[1] ETH Zurich, Surface Sci & Technol Lab, Dept Mat, CH-8092 Zurich, Switzerland
[2] ETH Zurich, Inst Biomed Engn & Sci, Dept Mat, CH-8092 Zurich, Switzerland
[3] Univ Cagliari, Dipartimento Chim Inorgan & Analit, I-09124 Cagliari, Italy
关键词
D O I
10.1021/la000736+
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Poly(L-lysine)-g-poly(ethylene glycol) (PLL-g-PEG) is a member of a family of polycationic PE G-grafted copolymers that have been shown to chemisorb on anionic surfaces, including various metal oxide surfaces, providing a high degree of resistance to protein adsorption. PLL-g-PEG-modified surfaces are attractive for a variety of applications including sensor chips for bioaffinity assays and blood-contacting biomedical devices. The analytical and structural properties of PLL-g-PEG adlayers on niobium oxide (Nb2O5), tantalum oxide (Ta2O5), and titanium oxide (TiO2) surfaces were investigated using reflection-absorption infrared spectroscopy (RAIRS), angle-dependent X-ray photoelectron spectroscopy (XPS), and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The combined analytical information provides clear evidence for an architecture with the cationic poly(L-lysine) attached electrostatically to the oxide surfaces (charged negatively at physiological pH) and the poly(ethylene oxide) side chains extending out from the surface. The relative intensities of the vibrational modes in the RAIRS spectra and the angle-dependent XPS data point to the PLL backbone being located directly at and parallel to the oxide/polymer interface, whereas the PEG chains are preferentially oriented in the direction perpendicular to the surface. Both positive and negative ToF-SIMS spectra are dominated by PEG-related secondary ion fragments with strongly reduced metal (oxide) intensities pointing to an (almost) complete coverage by the densely packed PEG comblike grafts. The three different transition metal oxide surfaces with isoelectric points well below 7 were found to behave very similarly, both in respect to the kinetics of the polymer adlayer adsorption and properties as well as in terms of protein resistance of the PLL-g-PEG-modified surface. Adsorption of serum and fibrinogen was evaluated using the OWLS optical planar waveguide technique. The amount of human serum adsorbed on the modified surfaces was consistently below the detection limit of the optical sensor technique used(<1-2 ng cm(-2)), and fibrinogen adsorption was reduced by 96-98% in comparison to the nonmodified (bare) oxide surfaces.
引用
收藏
页码:489 / 498
页数:10
相关论文
共 50 条
  • [41] Relationship between interfacial forces measured by colloid-probe atomic force microscopy and protein resistance of poly(ethylene glycol)-grafted poly(L-lysine) adlayers on niobia surfaces
    Pasche, S
    Textor, M
    Meagher, L
    Spencer, ND
    Griesser, HJ
    LANGMUIR, 2005, 21 (14) : 6508 - 6520
  • [42] Synthesis and characterization of biodegradable amphiphilic triblock copolymers methoxy-poly(ethylene glycol)-b-poly (L-lysine)-b-poly(L-lactic acid)
    Zhu, Ming-Qiang
    Xiang, Li
    Yang, Ke
    Shen, Lin-Jing
    Long, Feng
    Fan, Jun-Bing
    Yi, Hu-Qiang
    Xiang, Jiannan
    Aldred, Matthew P.
    JOURNAL OF POLYMER RESEARCH, 2012, 19 (02)
  • [43] Synthesis and characterization of biodegradable amphiphilic triblock copolymers methoxy-poly(ethylene glycol)-b-poly(L-lysine)-b-poly(L-lactic acid)
    Ming-Qiang Zhu
    Li Xiang
    Ke Yang
    Lin-Jing Shen
    Feng Long
    Jun-Bing Fan
    Hu-Qiang Yi
    Jiannan Xiang
    Matthew P. Aldred
    Journal of Polymer Research, 2012, 19
  • [44] RGD-containing peptide GCRGYGRGDSPG reduces enhancement of osteoblast differentiation by poly(L-lysine)-graft-poly(ethylene glycol)-coated titanium surfaces
    Tosatti, S
    Schwartz, Z
    Campbell, C
    Cochran, DL
    VandeVondele, S
    Hubbell, JA
    Denzer, A
    Simpson, J
    Wieland, M
    Lohmann, CH
    Textor, M
    Boyan, BD
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2004, 68A (03) : 458 - 472
  • [45] Microstructure characterization and thermal analysis of hybrid block copolymer α-methoxy-poly(ethylene glycol)-block-poly[ε-(benzyloxycarbonyl)-L-lysine] for biomedical applications
    Izunobi, Josephat U.
    Higginbotham, Clement L.
    JOURNAL OF MOLECULAR STRUCTURE, 2010, 977 (1-3) : 153 - 164
  • [46] Aqueous metal ions adsorption by poly(ethylene glycol)-modified graphene oxide: surface area and surface chemistry effects
    Yang, Jia-Ying
    Yue, Bao-Yu
    Teng, Jie
    Xu, Xia
    Zhao, Xiao-Ru
    Jiang, Xin-Yu
    Yu, Jin-Gang
    Zhou, Fang-Liang
    DESALINATION AND WATER TREATMENT, 2019, 138 : 147 - 158
  • [47] Adsorption properties of poly(L-lysine)-graft-poly(ethylene glycol) (PLL-g-PEG) at a hydrophobic interface:: Influence of tribological stress, pH, salt concentration, and polymer molecular weight
    Lee, Seunghwan
    Spencer, Nicholas D.
    LANGMUIR, 2008, 24 (17) : 9479 - 9488
  • [48] Physicochemical properties and nuclease resistance of antisense-oligodeoxynucleotides entrapped in the core of polyion complex micelles composed of poly(ethylene glycol)-poly(L-lysine) block copolymers
    Harada, A
    Togawa, H
    Kataoka, K
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2001, 13 (01) : 35 - 42
  • [49] X-ray photoelectron spectroscopy and radiometry studies of biotin-derivatized poly(L-lysine)-grafted-poly(ethylene glycol) monolayers on metal oxides
    Ruiz-Taylor, LA
    Martin, TL
    Wagner, P
    LANGMUIR, 2001, 17 (23) : 7313 - 7322
  • [50] Study on biodegradable polymer. 3. Synthesis and characterization of poly(DL-lactic acid)-co-poly(ethylene glycol)-co-poly(L-lysine) copolymer
    Deng, XM
    Liu, Y
    Yuan, ML
    EUROPEAN POLYMER JOURNAL, 2002, 38 (07) : 1435 - 1441