Poly(L-lysine)-g-poly(ethylene glycol) layers on metal oxide surfaces:: Surface-analytical characterization and resistance to serum and fibrinogen adsorption

被引:462
|
作者
Huang, NP
Michel, R
Voros, J
Textor, M
Hofer, R
Rossi, A
Elbert, DL
Hubbell, JA
Spencer, ND [1 ]
机构
[1] ETH Zurich, Surface Sci & Technol Lab, Dept Mat, CH-8092 Zurich, Switzerland
[2] ETH Zurich, Inst Biomed Engn & Sci, Dept Mat, CH-8092 Zurich, Switzerland
[3] Univ Cagliari, Dipartimento Chim Inorgan & Analit, I-09124 Cagliari, Italy
关键词
D O I
10.1021/la000736+
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Poly(L-lysine)-g-poly(ethylene glycol) (PLL-g-PEG) is a member of a family of polycationic PE G-grafted copolymers that have been shown to chemisorb on anionic surfaces, including various metal oxide surfaces, providing a high degree of resistance to protein adsorption. PLL-g-PEG-modified surfaces are attractive for a variety of applications including sensor chips for bioaffinity assays and blood-contacting biomedical devices. The analytical and structural properties of PLL-g-PEG adlayers on niobium oxide (Nb2O5), tantalum oxide (Ta2O5), and titanium oxide (TiO2) surfaces were investigated using reflection-absorption infrared spectroscopy (RAIRS), angle-dependent X-ray photoelectron spectroscopy (XPS), and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The combined analytical information provides clear evidence for an architecture with the cationic poly(L-lysine) attached electrostatically to the oxide surfaces (charged negatively at physiological pH) and the poly(ethylene oxide) side chains extending out from the surface. The relative intensities of the vibrational modes in the RAIRS spectra and the angle-dependent XPS data point to the PLL backbone being located directly at and parallel to the oxide/polymer interface, whereas the PEG chains are preferentially oriented in the direction perpendicular to the surface. Both positive and negative ToF-SIMS spectra are dominated by PEG-related secondary ion fragments with strongly reduced metal (oxide) intensities pointing to an (almost) complete coverage by the densely packed PEG comblike grafts. The three different transition metal oxide surfaces with isoelectric points well below 7 were found to behave very similarly, both in respect to the kinetics of the polymer adlayer adsorption and properties as well as in terms of protein resistance of the PLL-g-PEG-modified surface. Adsorption of serum and fibrinogen was evaluated using the OWLS optical planar waveguide technique. The amount of human serum adsorbed on the modified surfaces was consistently below the detection limit of the optical sensor technique used(<1-2 ng cm(-2)), and fibrinogen adsorption was reduced by 96-98% in comparison to the nonmodified (bare) oxide surfaces.
引用
收藏
页码:489 / 498
页数:10
相关论文
共 50 条
  • [31] Ligand-specific targeting of microspheres to phagocytes by surface modification with poly(L-lysine)-grafted poly(ethylene glycol) conjugate
    Faraasen, S
    Vörös, J
    Csúcs, G
    Textor, M
    Merkle, HP
    Walter, E
    PHARMACEUTICAL RESEARCH, 2003, 20 (02) : 237 - 246
  • [32] Poly(L-lysine)-graft-poly(ethylene glycol) assembled monolayers on niobium oxide surfaces:: A quantitative study of the influence of polymer interfacial architecture on resistance to protein adsorption by ToF-SIMS and in situ OWLS
    Pasche, S
    De Paul, SM
    Vörös, J
    Spencer, ND
    Textor, M
    LANGMUIR, 2003, 19 (22) : 9216 - 9225
  • [33] Immobilization of the enzyme β-lactamase on biotin-derivatized poly(L-lysine)-g-poly(ethylene glycol)-coated sensor chips:: A study on oriented attachment and surface activity by enzyme kinetics and in situ optical sensing
    Zhen, GL
    Eggli, V
    Vörös, J
    Zammaretti, P
    Textor, M
    Glockshuber, R
    Kuennemann, E
    LANGMUIR, 2004, 20 (24) : 10464 - 10473
  • [34] Biodegradable poly(ethylene glycol)-co-poly(L-lysine)-g-histidine multiblock copolymers for nonviral gene delivery
    Bikram, M
    Ahn, CH
    Chae, SY
    Lee, MY
    Yockman, JW
    Kim, SW
    MACROMOLECULES, 2004, 37 (05) : 1903 - 1916
  • [35] Remarkable increase in nuclease resistance of plasmid DNA through supramolecular assembly with poly(ethylene glycol) poly(L-lysine) block copolymer
    Katayose, S
    Kataoka, K
    JOURNAL OF PHARMACEUTICAL SCIENCES, 1998, 87 (02) : 160 - 163
  • [36] Derivatized poly(L-lysine)-graft-poly(ethylene glycol) monolayers as new biomolecular recognition interfaces on metal oxides.
    Ruiz-Taylor, LA
    Martin, TL
    Wagner, P
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U572 - U573
  • [37] A physico-chemical investigation of poly(ethylene oxide)-block-poly(L-lysine) copolymer adsorption onto silica nanoparticles
    Louguet, Stephanie
    Kumar, Anitha C.
    Sigaud, Gilles
    Duguet, Etienne
    Lecommandoux, Sebastien
    Schatz, Christophe
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2011, 359 (02) : 413 - 422
  • [38] Staphylococcus aureus adhesion to titanium oxide surfaces coated with non-functionalized and peptide-functionalized poly(L-lysine)-grafted-poly(ethylene glycol) copolymers
    Harris, LG
    Tosatti, S
    Wieland, M
    Textor, M
    Richards, RG
    BIOMATERIALS, 2004, 25 (18) : 4135 - 4148
  • [39] Microfluidic patterning of Si02 surfaces with derivatized poly(L-lysine)graft-poly(ethylene glycol) monolayers for biomolecular recognition.
    Martin, TL
    Ruiz-Taylor, LA
    Heidecker, M
    Wagner, P
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 219 : U525 - U525
  • [40] Synthesis and characterization of pH-sensitive conjugate of isoniazid - methoxypoly(ethylene glycol)-b-poly(L-lysine)
    Imramovsky, Ales
    Grusova, Ludmila
    Benes, Ludvik
    Pejchal, Vladimir
    Sedlak, Milos
    BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2012, 22 (18) : 5952 - 5955