Comparison of Real-Time Two-Dimensional and Three-Dimensional Contrast-Enhanced Ultrasound to Quantify Flow in an In Vitro Model: A Feasibility Study

被引:4
|
作者
Ruan, Si-Min [1 ]
Zheng, Qiao [2 ]
Wang, Zhu [1 ]
Hu, Hang-Tong [1 ]
Chen, Li-Da [1 ]
Guo, Huan-Ling [1 ]
Xie, Xiao-Yan [1 ]
Lu, Ming-De [1 ,3 ]
Li, Wei [1 ]
Wang, Wei [1 ]
机构
[1] Sun Yat Sen Univ, Inst Diagnost & Intervent Ultrasound, Dept Med Ultrason, Ultrason Artificial Intelligence X Lab,Affiliated, Guangzhou, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Fetal Med Ctr, Dept Med Ultrason, Affiliated Hosp 1, Guangzhou, Guangdong, Peoples R China
[3] Sun Yat Sen Univ, Dept Hepatobiliary Surg, Affiliated Hosp 1, Guangzhou, Guangdong, Peoples R China
来源
MEDICAL SCIENCE MONITOR | 2019年 / 25卷
关键词
Contrast Media; Imaging; Three-Dimensional; In Vitro; Ultrasonography; FOCAL LIVER-LESIONS; QUANTIFICATION; SUPERIOR; US;
D O I
10.12659/MSM.919160
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: This feasibility study aimed to compare real-time two-dimensional contrast-enhanced ultrasound (2D-CEUS) and three-dimensional contrast-enhanced ultrasound (3D-CEUS) to quantify flow in an in vitro model. Material/Methods: Five polyvinyl chloride (PVC) tubes were used for the perfusion models and used SonoVue ultrasound contrast agent with a perfusion volume ratio of 1: 2: 4: 8: 16. The contrast was injected at a constant speed to compare the raw quantitative data of 2D-CEUS and 3D-CEUS at angles of 0 degrees, 45 degrees, and 90 degrees. The coefficient of variation (CV) of the peak intensity (PI) in the model were compared and the correlations between weighted PI and perfusion volume were analyzed. Results: In the three angles used, real-time 3D-CEUS resulted in a more comprehensive view of the spatial relationships in the perfusion model. Using real-time 2D-CEUS, the mean CV was 0.92 +/- 0.36, and the mean CV in the real-time 3D-CEUS model was significantly less at 0.48 +/- 0.32 (p<0.001). Quantitative 3D-CEUS parameters showed a good correlation with those of 2D-CEUS with an r-value of 0.93 (p=0.02). The r-value of weighted PI and the perfusion ratio using 2D-CEUS was 0.66 (p=0.23) compared with values in 3D-CEUS of 0.84 (p=0.08). Conclusions: The combination of real-time 3D-CEUS and quantitative analysis identified the spatial distribution of the changes in angle in the model, which was less influenced by sectional planes, and was more representative of the perfusion volume when compared with 2D-CEUS. Quantitative real-time 3D-CEUS requires in vivo studies to evaluate the potential role in the clinical evaluation of vascular perfusion of malignant tumors.
引用
收藏
页码:10029 / 10035
页数:7
相关论文
共 50 条
  • [41] Feasibility of using a novel real-time three-dimensional technique for contrast dobutamine stress echocardiography
    Pulerwitz, T
    Hirata, K
    Otsuka, R
    Herz, S
    Fall, K
    Rivera, SA
    Desvarieux, MEN
    Bond, MP
    Di Tullio, MR
    Homma, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 294A - 294A
  • [42] Enhancement pattern of hepatocellular carcinoma: comparison of real-time contrast-enhanced ultrasound and contrast-enhanced computed tomography
    Liu, Guang-Jian
    Xu, Hui-Xiong
    Lu, Ming-De
    Xie, Xiao-Yan
    Xu, Zuo-Feng
    Zheng, Yan-Ling
    Liang, Jin-Yu
    CLINICAL IMAGING, 2006, 30 (05) : 315 - 321
  • [43] Two-dimensional and contrast-enhanced ultrasound of intestinal ischaemia in cats: four cases
    Linta, Nikolina
    Toaldo, Marco Baron
    Del Magno, Sara
    Pey, Pascaline
    Quinci, Manuela
    Diana, Alessia
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2020, 22 (04) : 384 - 390
  • [44] Real-time 3-dimensional contrast-enhanced ultrasound in detecting hemorrhage of blunt renal trauma
    Xu, Rui-Xue
    Li, Ye-Kuo
    Li, Ting
    Wang, Sha-Sha
    Yuan, Gui-Zhong
    Zhou, Qun-Fang
    Zheng, Hai-Rong
    Yan, Fei
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2013, 31 (10): : 1427 - 1431
  • [45] Comparison of matched-filtered two-dimensional projection and elliptical centric-ordered, three-dimensional contrast-enhanced magnetic resonance angiography
    Huang, YX
    Merchant, N
    Wright, GA
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (03) : 435 - 442
  • [46] Application of Contrast-Enhanced Real-time 3-Dimensional Ultrasound in Solid Abdominal Organ Trauma
    Feng, Cong
    Wang, Libo
    Huang, Sai
    Wang, Lili
    Zhou, Xuan
    Cui, Xiang
    Chen, Li
    Lv, Faqin
    Li, Tanshi
    JOURNAL OF ULTRASOUND IN MEDICINE, 2020, 39 (05) : 869 - 874
  • [47] The role of quantitation of real-time 3-dimensional contrast-enhanced ultrasound in detecting microvascular invasion: an in vivo study
    Wang, Zhu
    Wang, Wei
    Liu, Guang-Jian
    Yang, Zheng
    Chen, Li-Da
    Huang, Yang
    Li, Wei
    Xie, Xiao-Yan
    Lu, Ming-De
    Kuang, Ming
    ABDOMINAL RADIOLOGY, 2016, 41 (10) : 1973 - 1979
  • [48] The role of quantitation of real-time 3-dimensional contrast-enhanced ultrasound in detecting microvascular invasion: an in vivo study
    Zhu Wang
    Wei Wang
    Guang-Jian Liu
    Zheng Yang
    Li-Da Chen
    Yang Huang
    Wei Li
    Xiao-Yan Xie
    Ming-De Lu
    Ming Kuang
    Abdominal Radiology, 2016, 41 : 1973 - 1979
  • [49] Assessment of angiogenesis in rabbit orthotropic liver tumors using three-dimensional dynamic contrast-enhanced ultrasound compared with two-dimensional DCE-US
    Zheng, Qiao
    Zhang, Jian-chao
    Wang, Zhu
    Ruan, Si-Min
    Li, Wei
    Pan, Fu-Shun
    Chen, Li-Da
    Zhang, Yu-Chen
    Wu, Wen-Xin
    Xie, Xiao-Yan
    Lu, Ming-De
    Shan, Quan-Yuan
    Wang, Wei
    JAPANESE JOURNAL OF RADIOLOGY, 2019, 37 (10) : 701 - 709
  • [50] MR angiography of the vascular tree from the aorta to the foot: Combining two-dimensional time-of-flight and three-dimensional contrast-enhanced imaging
    Li, W
    Zhang, M
    Sher, S
    Edelman, RR
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 12 (06) : 884 - 889