Comparison of Real-Time Two-Dimensional and Three-Dimensional Contrast-Enhanced Ultrasound to Quantify Flow in an In Vitro Model: A Feasibility Study

被引:4
|
作者
Ruan, Si-Min [1 ]
Zheng, Qiao [2 ]
Wang, Zhu [1 ]
Hu, Hang-Tong [1 ]
Chen, Li-Da [1 ]
Guo, Huan-Ling [1 ]
Xie, Xiao-Yan [1 ]
Lu, Ming-De [1 ,3 ]
Li, Wei [1 ]
Wang, Wei [1 ]
机构
[1] Sun Yat Sen Univ, Inst Diagnost & Intervent Ultrasound, Dept Med Ultrason, Ultrason Artificial Intelligence X Lab,Affiliated, Guangzhou, Guangdong, Peoples R China
[2] Sun Yat Sen Univ, Fetal Med Ctr, Dept Med Ultrason, Affiliated Hosp 1, Guangzhou, Guangdong, Peoples R China
[3] Sun Yat Sen Univ, Dept Hepatobiliary Surg, Affiliated Hosp 1, Guangzhou, Guangdong, Peoples R China
来源
MEDICAL SCIENCE MONITOR | 2019年 / 25卷
关键词
Contrast Media; Imaging; Three-Dimensional; In Vitro; Ultrasonography; FOCAL LIVER-LESIONS; QUANTIFICATION; SUPERIOR; US;
D O I
10.12659/MSM.919160
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: This feasibility study aimed to compare real-time two-dimensional contrast-enhanced ultrasound (2D-CEUS) and three-dimensional contrast-enhanced ultrasound (3D-CEUS) to quantify flow in an in vitro model. Material/Methods: Five polyvinyl chloride (PVC) tubes were used for the perfusion models and used SonoVue ultrasound contrast agent with a perfusion volume ratio of 1: 2: 4: 8: 16. The contrast was injected at a constant speed to compare the raw quantitative data of 2D-CEUS and 3D-CEUS at angles of 0 degrees, 45 degrees, and 90 degrees. The coefficient of variation (CV) of the peak intensity (PI) in the model were compared and the correlations between weighted PI and perfusion volume were analyzed. Results: In the three angles used, real-time 3D-CEUS resulted in a more comprehensive view of the spatial relationships in the perfusion model. Using real-time 2D-CEUS, the mean CV was 0.92 +/- 0.36, and the mean CV in the real-time 3D-CEUS model was significantly less at 0.48 +/- 0.32 (p<0.001). Quantitative 3D-CEUS parameters showed a good correlation with those of 2D-CEUS with an r-value of 0.93 (p=0.02). The r-value of weighted PI and the perfusion ratio using 2D-CEUS was 0.66 (p=0.23) compared with values in 3D-CEUS of 0.84 (p=0.08). Conclusions: The combination of real-time 3D-CEUS and quantitative analysis identified the spatial distribution of the changes in angle in the model, which was less influenced by sectional planes, and was more representative of the perfusion volume when compared with 2D-CEUS. Quantitative real-time 3D-CEUS requires in vivo studies to evaluate the potential role in the clinical evaluation of vascular perfusion of malignant tumors.
引用
收藏
页码:10029 / 10035
页数:7
相关论文
共 50 条
  • [21] Real-time three-dimensional fetal echocardiography: Initial feasibility study
    Sklansky, MS
    Nelson, TR
    Strachan, MM
    Pretorius, DH
    CIRCULATION, 1999, 100 (18) : 394 - 394
  • [22] Real-time three-dimensional fetal echocardiography: Initial feasibility study
    Division of Pediatric Cardiology, University of California, San Diego, CA, United States
    不详
    不详
    J. Ultrasound Med., 11 (745-752):
  • [23] Comparison of real-time three-dimensional bicycle stress echocardiography with conventional two-dimensional bicycle stress echo
    Lethen, H.
    Tries, H. P.
    Zuercher, H.
    Lambertz, H.
    EUROPEAN HEART JOURNAL, 2006, 27 : 98 - 98
  • [24] Application of real-time three-dimensional contrast-enhanced ultrasound using SonoVue for the evaluation of focal liver lesions: a prospective single-center study
    Lu, Ying
    Liu, Baoxian
    Zheng, Yanling
    Luo, Jia
    Zhang, Xiaoer
    Huang, Guangliang
    Xie, Xiaohua
    Ye, Jieyi
    Wang, Wei
    Liu, Xusheng
    Xie, Xiaoyan
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2018, 10 (05): : 1469 - 1480
  • [25] Contrast sonography for uterine cavity assessment: A comparison of conventional two-dimensional with three-dimensional transvaginal ultrasound a pilot study
    Ayida, G
    Kennedy, S
    Barlow, D
    Chamberlain, P
    FERTILITY AND STERILITY, 1996, 66 (05) : 848 - 850
  • [26] Real-time processable three-dimensional fetal ultrasound
    Baba, K
    Okai, T
    Kozuma, S
    LANCET, 1996, 348 (9037): : 1307 - 1307
  • [27] Left ventricular mess measurements in cardiac patients using contrast-enhanced real-time three-dimensional echocardiography
    Sachdev, V
    Agyeman, KO
    Magno, PM
    Laurienzo, JM
    Freidlin, RZ
    Arai, AE
    Panza, JA
    CIRCULATION, 1999, 100 (18) : 356 - 356
  • [28] FEASIBILITY AND ACCURACY OF THE NOVEL THREE-DIMENSIONAL CAROTID ULTRASOUND TECHNIQUE: COMPARISON WITH TWO-DIMENSIONAL ULTRASOUND AND CAROTID CT ANGIOGRAPHY
    Heo, Ran
    Chang, Hyuk-Jae
    Cho, In-Jeong
    Park, Jinki
    Lee, Jinyong
    Shim, Chi Young
    Hong, Geu-Ru
    Chung, Namsik
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 1655 - 1655
  • [29] Three-dimensional Contrast-enhanced Ultrasound in Response Assessment for Breast Cancer: A Comparison with Dynamic Contrast-enhanced Magnetic Resonance Imaging and Pathology
    Jia, Wan-Ru
    Tang, Lei
    Wang, Deng-Bin
    Chai, Wei-Min
    Fei, Xiao-Chun
    He, Jian-Rong
    Chen, Man
    Wang, Wen-Ping
    SCIENTIFIC REPORTS, 2016, 6
  • [30] Three-dimensional Contrast-enhanced Ultrasound in Response Assessment for Breast Cancer: A Comparison with Dynamic Contrast-enhanced Magnetic Resonance Imaging and Pathology
    Wan-Ru Jia
    Lei Tang
    Deng-Bin Wang
    Wei-Min Chai
    Xiao-Chun Fei
    Jian-Rong He
    Man Chen
    Wen-Ping Wang
    Scientific Reports, 6