An augmented reality C-arm for intraoperative assessment of the mechanical axis: a preclinical study

被引:16
|
作者
Fallavollita, Pascal [1 ]
Brand, Alexander [2 ]
Wang, Lejing [1 ]
Euler, Ekkehard [2 ]
Thaller, Peter [2 ]
Navab, Nassir [1 ]
Weidert, Simon [2 ]
机构
[1] Tech Univ Munich, Munich, Germany
[2] Klinikum Univ Munchen, Klin Allgemeine Unfall Hand & Plast Chirurg, Munich, Germany
关键词
C-arm fluoroscopy; Augmented reality; Intraoperative navigation; Tibial osteotomy; Mechanical axis deviation; Lower limb alignment; DEVIATION; CADAVER; LENGTH;
D O I
10.1007/s11548-016-1426-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Determination of lower limb alignment is a prerequisite for successful orthopedic surgical treatment. Traditional methods include the electrocautery cord, alignment rod, or axis board which rely solely on C-arm fluoroscopy navigation and are radiation intensive. To assess a new augmented reality technology in determining lower limb alignment. A camera-augmented mobile C-arm (CamC) technology was used to create a panorama image consisting of hip, knee, and ankle X-rays. Twenty-five human cadaver legs were used for validation with random varus or valgus deformations. Five clinicians performed experiments that consisted in achieving acceptable mechanical axis deviation. The applicability of the CamC technology was assessed with direct comparison to ground-truth CT. A t test, Pearson's correlation, and ANOVA were used to determine statistical significance. The value of Pearson's correlation coefficient R was 0.979 which demonstrates a strong positive correlation between the CamC and ground-truth CT data. The analysis of variance produced a p value equal to 0.911 signifying that clinician expertise differences were not significant with regard to the type of system used to assess mechanical axis deviation. All described measurements demonstrated valid measurement of lower limb alignment. With minimal effort, clinicians required only 3 X-ray image acquisitions using the augmented reality technology to achieve reliable mechanical axis deviation.
引用
收藏
页码:2111 / 2117
页数:7
相关论文
共 50 条
  • [41] Assessment of Lumbar Spine Instability Using C-Arm Fluoroscopy
    Temes, Bill
    Karas, Steve
    Manwill, James
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2016, 46 (09): : 810 - 810
  • [42] Myocardial perfusion assessment using C-arm CT angiography
    Rieber, J.
    Sinha, A.
    Schmidt, M.
    Lauritsch, G.
    Koenig, A.
    Klauss, V.
    Rittger, H.
    EUROPEAN HEART JOURNAL, 2010, 31 : 578 - 578
  • [43] C-arm based computed tomography - A comparative study
    Wirth, S
    Euler, E
    Linsenmaier, U
    Rock, C
    Kotsianos, D
    Brandl, R
    Mutschler, W
    Pfeifer, KJ
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 408 - 413
  • [44] Development of an intraoperative 3D C-arm technique for torsion control of femur fractures: a cadaver study
    Stubig, T.
    Aidarous, H.
    Khalifa, A.
    Omar, M.
    Krettek, C.
    Pacha, T. Omar
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (11) : 1739 - 1743
  • [45] Development and evaluation of an open-source virtual reality C-Arm simulator
    Allen, Daniel R.
    Clarke, Collin
    Peters, Terry M.
    Chen, Elvis C. S.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2023, 11 (04): : 1090 - 1095
  • [46] Model of a vascular C-arm for 3D augmented fluoroscopy in interventional radiology
    Gorges, S
    Kerrien, E
    Berger, MO
    Trousset, Y
    Pescatore, J
    Anxionnat, R
    Picard, L
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 2, 2005, 3750 : 214 - 222
  • [47] Development of an intraoperative 3D C-arm technique for torsion control of femur fractures: a cadaver study
    T. Stubig
    H. Aidarous
    A. Khalifa
    M. Omar
    C. Krettek
    T. Omar Pacha
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 1739 - 1743
  • [48] Radiation protection for an intraoperative X-ray source compared to C-arm fluoroscopy
    Schneider, Frank
    Clausen, Sven
    Jahnke, Anika
    Steil, Volker
    Bludau, Frederic
    Suetterlin, Marc
    Obertacke, Udo
    Wenz, Frederik
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2014, 24 (03): : 243 - 251
  • [49] Utility of intraoperative diagnostic C-arm angiography for management of high grade subarachnoid hemorrhage
    Wei, Zhikui
    Garzon-Muvdi, Tomas
    Yang, Wuyang
    Caplan, Justin M.
    Radvany, Martin G.
    Colby, Geoffrey P.
    Coon, Alexander L.
    Tamargo, Rafael J.
    Huang, Judy
    INTERDISCIPLINARY NEUROSURGERY-ADVANCED TECHNIQUES AND CASE MANAGEMENT, 2015, 2 (02): : 98 - 102
  • [50] A method for a C-arm controlled intraoperative evaluation of the hip tilt for total endoprosthesis implantation
    Hoechel, Sebastian
    Blache, Sandra
    Mueller-Gerbl, Magdalena
    Nowakowski, Andrej
    SWISS MEDICAL WEEKLY, 2017, 147 : 50S - 50S