An augmented reality C-arm for intraoperative assessment of the mechanical axis: a preclinical study

被引:16
|
作者
Fallavollita, Pascal [1 ]
Brand, Alexander [2 ]
Wang, Lejing [1 ]
Euler, Ekkehard [2 ]
Thaller, Peter [2 ]
Navab, Nassir [1 ]
Weidert, Simon [2 ]
机构
[1] Tech Univ Munich, Munich, Germany
[2] Klinikum Univ Munchen, Klin Allgemeine Unfall Hand & Plast Chirurg, Munich, Germany
关键词
C-arm fluoroscopy; Augmented reality; Intraoperative navigation; Tibial osteotomy; Mechanical axis deviation; Lower limb alignment; DEVIATION; CADAVER; LENGTH;
D O I
10.1007/s11548-016-1426-z
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Determination of lower limb alignment is a prerequisite for successful orthopedic surgical treatment. Traditional methods include the electrocautery cord, alignment rod, or axis board which rely solely on C-arm fluoroscopy navigation and are radiation intensive. To assess a new augmented reality technology in determining lower limb alignment. A camera-augmented mobile C-arm (CamC) technology was used to create a panorama image consisting of hip, knee, and ankle X-rays. Twenty-five human cadaver legs were used for validation with random varus or valgus deformations. Five clinicians performed experiments that consisted in achieving acceptable mechanical axis deviation. The applicability of the CamC technology was assessed with direct comparison to ground-truth CT. A t test, Pearson's correlation, and ANOVA were used to determine statistical significance. The value of Pearson's correlation coefficient R was 0.979 which demonstrates a strong positive correlation between the CamC and ground-truth CT data. The analysis of variance produced a p value equal to 0.911 signifying that clinician expertise differences were not significant with regard to the type of system used to assess mechanical axis deviation. All described measurements demonstrated valid measurement of lower limb alignment. With minimal effort, clinicians required only 3 X-ray image acquisitions using the augmented reality technology to achieve reliable mechanical axis deviation.
引用
收藏
页码:2111 / 2117
页数:7
相关论文
共 50 条
  • [21] Intraoperative assessment after pediatric cardiac surgical repair: Initial experience with C-arm angiography
    Shuhaiber, Jeffrey H.
    Bergersen, Lisa
    Pigula, Frank
    Emani, Sitaram
    McElhinney, Doff
    Marshall, Audrey
    Fynn-Thompson, Francis
    Bacha, Emile A.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (01): : E1 - E3
  • [22] Camera Augmented Mobile C-Arm (CAMC): Calibration, Accuracy Study, and Clinical Applications
    Navab, Nassir
    Heining, Sandro-Michael
    Traub, Joerg
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (07) : 1412 - 1423
  • [23] First Animal Cadaver Study for Interlocking of Intramedullary Nails under Camera Augmented Mobile C-arm A Surgical Workflow Based Preclinical Evaluation
    Wang, Lejing
    Landes, Juergen
    Weidert, Simon
    Blum, Tobias
    von der Heide, Anna
    Euler, Ekkehard
    Navab, Nassir
    INFORMATION PROCESSING IN COMPUTER-ASSISTED INTERVENTIONS, 2010, 6135 : 56 - +
  • [24] Dynamic intraoperative dosimetry for prostate brachytherapy using a nonisocentric C-arm
    Song, Danny Y.
    Jain, Ameet K.
    Zhang, Zhe
    Deguet, Anton
    Le, Yi
    Armour, Elwood
    Burdette, E. Clif
    Fichtinger, Gabor
    BRACHYTHERAPY, 2011, 10 (02) : 98 - 106
  • [25] Intraoperative segmentation of iodine and palladium radioactive sources in C-arm images
    Chiara Amat di San Filippo
    Gabor Fichtinger
    William James Morris
    Septimiu E. Salcudean
    Ehsan Dehghan
    Pascal Fallavollita
    International Journal of Computer Assisted Radiology and Surgery, 2014, 9 : 769 - 776
  • [26] Intraoperative C-Arm Radiation Affecting Factors and Reduction by an Intervention Program
    Bar-On, Elhanan
    Weigl, Daniel Martin
    Becker, Tali
    Katz, Kalman
    Konen, Osnat
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2010, 30 (04) : 320 - 323
  • [27] Toward an End-to-End Calibration for Mobile C-Arm in Combination with a Depth Sensor for Surgical Augmented Reality Applications
    Hosseinian, Sahar
    Arefi, Hossein
    Navab, Nassir
    SENSORS, 2020, 20 (01)
  • [28] Virtual fluoroscopy for intraoperative C-arm positioning and radiation dose reduction
    De Silva, Tharindu
    Punnoose, Joshua
    Uneri, Ali
    Mahesh, Mahadevappa
    Goerres, Joseph
    Jacobson, Matthew
    Ketcha, Michael D.
    Manbachi, Amir
    Vogt, Sebastian
    Kleinszig, Gerhard
    Khanna, Akhil Jay
    Wolinksy, Jean-Paul
    Siewerdsen, Jeffrey H.
    Osgood, Greg
    JOURNAL OF MEDICAL IMAGING, 2018, 5 (01)
  • [29] Intraoperative segmentation of iodine and palladium radioactive sources in C-arm images
    di San Filippo, Chiara Amat
    Fichtinger, Gabor
    Morris, William James
    Salcudean, Septimiu E.
    Dehghan, Ehsan
    Fallavollita, Pascal
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (05) : 769 - 776
  • [30] Use of a C-Arm Fluoroscopy Simulator to Support Training in Intraoperative Radiography
    Bott, Oliver Johannes
    Dresing, Klaus
    Wagner, Markus
    Raab, Bjoern-Werner
    Teistler, Michael
    RADIOGRAPHICS, 2011, 31 (03) : E31 - E41