Hand-Powered Microfluidics for Parallel Droplet Digital Loop-Mediated Isothermal Amplification Assays

被引:24
|
作者
Yuan, Hao [1 ,2 ]
Tian, Jingxuan [3 ]
Chao, Youchuang [3 ]
Chien, Yuh-Shiuan [2 ]
Luo, Ren-Hao [2 ]
Guo, Jun-Yu [2 ]
Li, Shanshan [4 ]
Chou, Yi-Ju [2 ]
Shum, Ho Cheung [3 ]
Chen, Chien-Fu [2 ]
机构
[1] Southwest Jiaotong Univ, Sch Life Sci & Engn, Chengdu 610031, Sichuan, Peoples R China
[2] Natl Taiwan Univ, Inst Appl Mech, Taipei 106, Taiwan
[3] Univ Hong Kong, Dept Mech Engn, Pok Fu Lam, Hong Kong, Peoples R China
[4] Univ Hong Kong, Dept Clin Oncol, Shenzhen Hosp, Shenzhen 518009, Peoples R China
来源
ACS SENSORS | 2021年 / 6卷 / 08期
关键词
droplet digital loop-mediated isothermal amplification; droplet microfluidics; pathogen detection; compartmentalization; nucleic acid quantification; droplet generation; multi-sample detection; LAMP; DNA;
D O I
10.1021/acssensors.1c00184
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Droplet digital loop-mediated isothermal amplification (ddLAMP) is an important assay for pathogen detection due to its high accuracy, specificity, and ability to quantify nucleic acids. However, performing ddLAMP requires expensive instrumentation and the need for highly trained personnel with expertise in microfluidics. To make ddLAMP more accessible, a ddLAMP assay is developed, featuring significantly decreased operational difficulty and instrumentation requirements. The proposed assay consists of three simplified steps: (1) droplet generation step, in which a LAMP mixture can be emulsified just by manually pulling a syringe connected to a microfluidic device. In this step, for the first time, we verify that highly monodispersed droplets can be generated with unstable flow rates or pressures, allowing untrained personnel to operate the microfluidic device and perform ddLAMP assay; (2) heating step, in which the droplets are isothermally heated in a water bath, which can be found in most laboratories; and (3) result analysis step, in which the ddLAMP result can be determined using only a fluorescence microscopy and an open-source analyzing software. Throughout the process, no droplet microfluidic expertise or equipment is required. More importantly, the proposed system enables multiple samples to be processed simultaneously with a detection limit of 10 copies/mu L. The test is simple and intuitive to operate in most laboratories for multi-sample detection, significantly enhancing the accessibility and detection throughput of the ddLAMP technique.
引用
收藏
页码:2868 / 2874
页数:7
相关论文
共 50 条
  • [31] Development of rapid in-field loop-mediated isothermal amplification (LAMP) assays for phytoplasmas
    Hodgetts, Jennifer
    Tomlinson, Jenny
    Boonham, Neil
    Gonzalez-Martin, Irene
    Nikolic, Petra
    Swarbrick, Philip
    Yankey, Egya N.
    Dickinson, Matthew
    BULLETIN OF INSECTOLOGY, 2011, 64 : S41 - S42
  • [32] Development of loop-mediated isothermal amplification assays for rapid and easy detection of Coxiella Burnetii
    Chen, Hua-Wei
    Ching, Wei-Mei
    JOURNAL OF MICROBIOLOGICAL METHODS, 2014, 107 : 176 - 181
  • [33] Development of Loop-Mediated Isothermal Amplification (LAMP) Assays for Rapid Detection of Ehrlichia ruminantium
    Nakao, Ryo
    Stromdahl, Ellen Y.
    Magona, Joseph W.
    Faburay, Bonto
    Namangala, Boniface
    Malele, Imna
    Inoue, Noboru
    Geysen, Dirk
    Kajino, Kiichi
    Jongejan, Frans
    Sugimoto, Chihiro
    BMC MICROBIOLOGY, 2010, 10
  • [34] LampPort: a handheld digital microfluidic device for loop-mediated isothermal amplification (LAMP)
    Wan, Liang
    Gao, Jie
    Chen, Tianlan
    Dong, Cheng
    Li, Haoran
    Wen, Yan-Zi
    Lun, Zhao-Rong
    Jia, Yanwei
    Mak, Pui-In
    Martins, Rui P.
    BIOMEDICAL MICRODEVICES, 2019, 21 (01)
  • [35] Microfluidic Encapsulation of DNAs in Liquid Beads for Digital Loop-Mediated Isothermal Amplification
    Galogahi, Fariba Malekpour
    Strachan, Simon
    Yadav, Ajeet Singh
    Stratton, Helen
    Nguyen, Nam-Trung
    ADVANCED NANOBIOMED RESEARCH, 2024, 4 (12):
  • [36] LampPort: a handheld digital microfluidic device for loop-mediated isothermal amplification (LAMP)
    Liang Wan
    Jie Gao
    Tianlan Chen
    Cheng Dong
    Haoran Li
    Yan-Zi Wen
    Zhao-Rong Lun
    Yanwei Jia
    Pui-In Mak
    Rui P. Martins
    Biomedical Microdevices, 2019, 21
  • [37] An integrated array-based emulsion droplet microfluidic device for digital loop-mediated isothermal amplification (LAMP) analysis
    Luo, Kang
    Ma, Yu-Dong
    Chang, Wen-Hsin
    Lee, Gwo-Bin
    2016 IEEE 11TH ANNUAL INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2016,
  • [38] Diagnostic value of loop-mediated isothermal amplification assay for hand, foot, and mouth disease
    Chen, Ying-Zhou
    Zhan, Zhi-Qing
    Zhou, Li-Quan
    Chen, Min-Shan
    Cao, Xun-Jie
    Li, Ya-Ping
    Guo, Xu-Guang
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2021, 35 (06)
  • [39] On-chip parallel detection of foodborne pathogens using loop-mediated isothermal amplification
    Duarte, Carlos
    Salm, Eric
    Dorvel, Brian
    Reddy, Bobby, Jr.
    Bashir, Rashid
    BIOMEDICAL MICRODEVICES, 2013, 15 (05) : 821 - 830
  • [40] Recombinase assisted loop-mediated isothermal DNA amplification
    Chen, Gangyi
    Chen, Rong
    Ding, Sheng
    Li, Mei
    Wang, Jiayu
    Zou, Jiawei
    Du, Feng
    Dong, Juan
    Cui, Xin
    Huang, Xin
    Deng, Yun
    Tang, Zhuo
    ANALYST, 2020, 145 (02) : 440 - 444