Hand-Powered Microfluidics for Parallel Droplet Digital Loop-Mediated Isothermal Amplification Assays

被引:24
|
作者
Yuan, Hao [1 ,2 ]
Tian, Jingxuan [3 ]
Chao, Youchuang [3 ]
Chien, Yuh-Shiuan [2 ]
Luo, Ren-Hao [2 ]
Guo, Jun-Yu [2 ]
Li, Shanshan [4 ]
Chou, Yi-Ju [2 ]
Shum, Ho Cheung [3 ]
Chen, Chien-Fu [2 ]
机构
[1] Southwest Jiaotong Univ, Sch Life Sci & Engn, Chengdu 610031, Sichuan, Peoples R China
[2] Natl Taiwan Univ, Inst Appl Mech, Taipei 106, Taiwan
[3] Univ Hong Kong, Dept Mech Engn, Pok Fu Lam, Hong Kong, Peoples R China
[4] Univ Hong Kong, Dept Clin Oncol, Shenzhen Hosp, Shenzhen 518009, Peoples R China
来源
ACS SENSORS | 2021年 / 6卷 / 08期
关键词
droplet digital loop-mediated isothermal amplification; droplet microfluidics; pathogen detection; compartmentalization; nucleic acid quantification; droplet generation; multi-sample detection; LAMP; DNA;
D O I
10.1021/acssensors.1c00184
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Droplet digital loop-mediated isothermal amplification (ddLAMP) is an important assay for pathogen detection due to its high accuracy, specificity, and ability to quantify nucleic acids. However, performing ddLAMP requires expensive instrumentation and the need for highly trained personnel with expertise in microfluidics. To make ddLAMP more accessible, a ddLAMP assay is developed, featuring significantly decreased operational difficulty and instrumentation requirements. The proposed assay consists of three simplified steps: (1) droplet generation step, in which a LAMP mixture can be emulsified just by manually pulling a syringe connected to a microfluidic device. In this step, for the first time, we verify that highly monodispersed droplets can be generated with unstable flow rates or pressures, allowing untrained personnel to operate the microfluidic device and perform ddLAMP assay; (2) heating step, in which the droplets are isothermally heated in a water bath, which can be found in most laboratories; and (3) result analysis step, in which the ddLAMP result can be determined using only a fluorescence microscopy and an open-source analyzing software. Throughout the process, no droplet microfluidic expertise or equipment is required. More importantly, the proposed system enables multiple samples to be processed simultaneously with a detection limit of 10 copies/mu L. The test is simple and intuitive to operate in most laboratories for multi-sample detection, significantly enhancing the accessibility and detection throughput of the ddLAMP technique.
引用
收藏
页码:2868 / 2874
页数:7
相关论文
共 50 条
  • [21] Applications of Loop-Mediated Isothermal DNA Amplification
    Shijun Fu
    Guanggang Qu
    Shijin Guo
    Lin Ma
    Na Zhang
    Songlin Zhang
    Sanyang Gao
    Zhiqiang Shen
    Applied Biochemistry and Biotechnology, 2011, 163 : 845 - 850
  • [22] Application of loop-mediated isothermal amplification (LAMP) assays for the detection of bovine herpesvirus 1
    Socha, W.
    Rola, J.
    Urban-Chmiel, R.
    Imudzinski, J. F.
    POLISH JOURNAL OF VETERINARY SCIENCES, 2017, 20 (03): : 619 - 622
  • [23] A Portable Digital Loop-Mediated Isothermal Amplification Platform Based on Microgel Array and Hand-Held Reader
    Cao, Lei
    Guo, Xiaojin
    Mao, Ping
    Ren, Yulin
    Li, Zedong
    You, Minli
    Hu, Jie
    Tian, Miao
    Yao, Chunyan
    Li, Fei
    Xu, Feng
    ACS SENSORS, 2021, 6 (10): : 3564 - 3574
  • [24] Pathogenic Bacteria Detection Using RNA-Based Loop-Mediated Isothermal-Amplification-Assisted Nucleic Acid Amplification via Droplet Microfluidics
    Azizi, Morteza
    Zaferani, Meisam
    Cheong, Soon Hon
    Abbaspourrad, Alireza
    ACS SENSORS, 2019, 4 (04): : 841 - 848
  • [25] Loop-mediated isothermal amplification assays: Rapid and efficient diagnostics for genetically modified crops
    Singh, Monika
    Pal, Deepa
    Soo, Payal
    Randhawa, Gurinderjit
    FOOD CONTROL, 2019, 106
  • [26] Development of Loop-Mediated Isothermal Amplification (LAMP) Assays for Rapid Detection of Ehrlichia ruminantium
    Ryo Nakao
    Ellen Y Stromdahl
    Joseph W Magona
    Bonto Faburay
    Boniface Namangala
    Imna Malele
    Noboru Inoue
    Dirk Geysen
    Kiichi Kajino
    Frans Jongejan
    Chihiro Sugimoto
    BMC Microbiology, 10
  • [27] Development of loop-mediated isothermal amplification (LAMP) assays for the detection of Plum pox virus
    Gao, Y.
    Li, M.
    Wang, J.
    PHYTOPATHOLOGY, 2011, 101 (06) : S58 - S58
  • [28] Integrated Droplet-Based Digital Loop-Mediated Isothermal Amplification Microfluidic Chip with Droplet Generation, Incubation, and Continuous Fluorescence Detection
    Lin, Yen-Heng
    Hung, Yuan-Ting
    Chang, Wei
    Chiou, Chiuan-Chian
    BIOSENSORS-BASEL, 2024, 14 (07):
  • [29] Rapid detection of European orthobunyaviruses by reverse transcription loop-mediated isothermal amplification assays
    Camp, Jeremy V.
    Nowotny, Norbert
    JOURNAL OF VIROLOGICAL METHODS, 2016, 236 : 252 - 257
  • [30] Loop-mediated isothermal amplification assays for the detection of antimicrobial resistance elements in Vibrio cholera
    Negron, Daniel Antonio
    Trivedi, Shipra
    Tolli, Nicholas
    Ashford, David
    Melton, Gabrielle
    Guertin, Stephanie
    Jennings, Katharine
    Necciai, Bryan D.
    Sozhamannan, Shanmuga
    Abramson, Bradley W.
    BMC BIOINFORMATICS, 2024, 25 (01):