Optimization on non-transparent envelopes of the typical office rooms with air-conditioning under intermittent operation

被引:20
|
作者
Gao, Yanna [1 ,2 ]
Meng, Xi [1 ,2 ]
Shi, Xinyu [1 ,2 ]
Wang, Ziyun [3 ]
Long, Enshen [3 ]
Gao, Weijun [1 ,2 ,4 ]
机构
[1] Qingdao Univ Technol, Innovat Inst Sustainable Maritime Architecture Re, Qingdao 266033, Peoples R China
[2] Qingdao Univ Technol, Coll Architecture & Urban Planning, Qingdao 266033, Peoples R China
[3] Sichuan Univ, Coll Architecture & Environm, Chengdu 610065, Peoples R China
[4] Univ Kitakyushu, Fac Environm Engn, Kitakyushu, Fukuoka 8080135, Japan
基金
中国国家自然科学基金;
关键词
Cooling load; Envelope components; Inner surface heat flow; Air-conditioning intermittent operation; THERMAL PERFORMANCE; ENERGY-CONSUMPTION; WALL INSULATION; BUILDINGS; COEFFICIENT; SIMULATION; THICKNESS;
D O I
10.1016/j.solener.2020.03.074
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In present energy conservation design, air-conditioning operation is deemed to be continuous in the whole building, but the intermittent operation of air-conditioning is widely applied due to the occupant's behaviour. The large discrepancy in the energy efficiency and energy consumption can cause between the actual usage and the primary design. Considering this situation, a numerical simulation was carried on to optimize the thermal performance of non-transparent envelope components in three typical rooms with air-conditioning under the intermittent operation in summer. The energy-saving potential of all components was analysed, while the whole heat transfer capacities in three typical rooms were compared between traditional and optimized envelopes. Results showed by optimizing envelope components, the average heat flow values could be reduced by up to 13.78-71.27%, while the average heat transfer capacities were reduced by 33-39% and their fluctuation percentages were also decreased obviously. Compared to interior and exterior walls, floors and ceilings had the higher energy-saving contribution percentages of 35-80% and the larger the room area, the larger the energy-saving contribution percentage of floors and ceilings.
引用
收藏
页码:798 / 809
页数:12
相关论文
共 43 条
  • [41] Performance evaluation of a waste-heat driven adsorption system for automotive air-conditioning: Part II - Performance optimization under different real driving conditions
    Verde, M.
    Harby, K.
    de Boer, Robert
    Corberan, Jose M.
    ENERGY, 2016, 115 : 996 - 1009
  • [42] 4E analysis and optimization of cold thermal-energy storage under partial operating mode and demand-limiting mode for air-conditioning systems
    Hosseinjany, Salar
    Ahmadi-Danesh-Ashtiani, Hossien
    Khoshgard, Ahmad
    Fazaeli, Reza
    CLEAN ENERGY, 2023, 7 (03): : 582 - 594
  • [43] Embodied and Operational Carbon of Typical Heating, Ventilation and Air Conditioning (HVAC) Systems in Office Buildings in Washington State: A study of buildings registered under LEED v3 2009
    Rodriguez, B. X.
    Amany, L.
    Simonen, K.
    SUSTAINABLE BUILT ENVIRONMENT CONFERENCE 2019 TOKYO (SBE19TOKYO) - BUILT ENVIRONMENT IN AN ERA OF CLIMATE CHANGE: HOW CAN CITIES AND BUILDINGS ADAPT?, 2019, 294