Optimization on non-transparent envelopes of the typical office rooms with air-conditioning under intermittent operation

被引:20
|
作者
Gao, Yanna [1 ,2 ]
Meng, Xi [1 ,2 ]
Shi, Xinyu [1 ,2 ]
Wang, Ziyun [3 ]
Long, Enshen [3 ]
Gao, Weijun [1 ,2 ,4 ]
机构
[1] Qingdao Univ Technol, Innovat Inst Sustainable Maritime Architecture Re, Qingdao 266033, Peoples R China
[2] Qingdao Univ Technol, Coll Architecture & Urban Planning, Qingdao 266033, Peoples R China
[3] Sichuan Univ, Coll Architecture & Environm, Chengdu 610065, Peoples R China
[4] Univ Kitakyushu, Fac Environm Engn, Kitakyushu, Fukuoka 8080135, Japan
基金
中国国家自然科学基金;
关键词
Cooling load; Envelope components; Inner surface heat flow; Air-conditioning intermittent operation; THERMAL PERFORMANCE; ENERGY-CONSUMPTION; WALL INSULATION; BUILDINGS; COEFFICIENT; SIMULATION; THICKNESS;
D O I
10.1016/j.solener.2020.03.074
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In present energy conservation design, air-conditioning operation is deemed to be continuous in the whole building, but the intermittent operation of air-conditioning is widely applied due to the occupant's behaviour. The large discrepancy in the energy efficiency and energy consumption can cause between the actual usage and the primary design. Considering this situation, a numerical simulation was carried on to optimize the thermal performance of non-transparent envelope components in three typical rooms with air-conditioning under the intermittent operation in summer. The energy-saving potential of all components was analysed, while the whole heat transfer capacities in three typical rooms were compared between traditional and optimized envelopes. Results showed by optimizing envelope components, the average heat flow values could be reduced by up to 13.78-71.27%, while the average heat transfer capacities were reduced by 33-39% and their fluctuation percentages were also decreased obviously. Compared to interior and exterior walls, floors and ceilings had the higher energy-saving contribution percentages of 35-80% and the larger the room area, the larger the energy-saving contribution percentage of floors and ceilings.
引用
收藏
页码:798 / 809
页数:12
相关论文
共 43 条
  • [21] High velocity seawater air-conditioning with thermal energy storage and its operation with intermittent renewable energies
    Julian David Hunt
    Behnam Zakeri
    Andreas Nascimento
    Bruno Garnier
    Márcio Giannini Pereira
    Rodrigo Augusto Bellezoni
    Natália de Assis Brasil Weber
    Paulo Smith Schneider
    Pedro Paulo Bezerra Machado
    Dorel Soares Ramos
    Energy Efficiency, 2020, 13 : 1825 - 1840
  • [22] Optimization of the thermal performance of self-insulation hollow blocks under conditions of cold climate and intermittent running of air-conditioning
    Hu, Wentao
    Huang, Yue
    Yuan, Meng
    Zhang, Jiaying
    Alekhin, V. N.
    CASE STUDIES IN THERMAL ENGINEERING, 2022, 35
  • [23] Heat exchange characteristics of non-azeotropic refrigerants in condenser in air-conditioning operation
    Department of Thermal Engineering, School of Mechanical Engineering, Tianjin University, Tianjin 300072, China
    Huagong Xuebao, 2006, 6 (1309-1313):
  • [24] Heat exchanging characters of non-azeotropic refrigerants evaporating with air-conditioning operation
    Zhao, Li
    Jiang, Dong-Liang
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban)/Journal of Tianjin University Science and Technology, 2006, 39 (06): : 670 - 674
  • [25] Optimization strategy for joint operation of kitchen air-conditioning and fan based on energy consumption and comfort
    Zhang, Shunyu
    Shen, Zhihang
    Chen, Zhenlei
    BUILDING AND ENVIRONMENT, 2025, 276
  • [26] Thermal performance assessment of exterior building walls under intermittent air-conditioning operation in China's hot summer and cold winter zone
    Xu, Lu
    Ding, Yong
    Du, Chenqiu
    JOURNAL OF BUILDING ENGINEERING, 2024, 95
  • [27] Qualitative Experimental research on thermal response of interior finishing material under air-conditioning intermittent running
    Deng, Zihan
    Cu, Naisheng
    Meng, Xi
    Zeng, Qian
    He, Hanfei
    Li, Ling
    Wang, Yaoyao
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 410 - 414
  • [28] Facility performance evaluation to develop heating, ventilation, and air-conditioning system design and operation strategies for an office building in Mongolia
    Rhee, Kyu-Nam
    INDOOR AND BUILT ENVIRONMENT, 2016, 25 (08) : 1209 - 1225
  • [29] Bi-level Optimization Method of Air-conditioning System Based on Office Building Energy Storage Characteristics
    Wang, Qingze
    Chen, Xingying
    Ji, Li
    Liao, Yingchen
    Yu, Kun
    2017 2ND ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2017), 2017, 199