Optimization on non-transparent envelopes of the typical office rooms with air-conditioning under intermittent operation

被引:20
|
作者
Gao, Yanna [1 ,2 ]
Meng, Xi [1 ,2 ]
Shi, Xinyu [1 ,2 ]
Wang, Ziyun [3 ]
Long, Enshen [3 ]
Gao, Weijun [1 ,2 ,4 ]
机构
[1] Qingdao Univ Technol, Innovat Inst Sustainable Maritime Architecture Re, Qingdao 266033, Peoples R China
[2] Qingdao Univ Technol, Coll Architecture & Urban Planning, Qingdao 266033, Peoples R China
[3] Sichuan Univ, Coll Architecture & Environm, Chengdu 610065, Peoples R China
[4] Univ Kitakyushu, Fac Environm Engn, Kitakyushu, Fukuoka 8080135, Japan
基金
中国国家自然科学基金;
关键词
Cooling load; Envelope components; Inner surface heat flow; Air-conditioning intermittent operation; THERMAL PERFORMANCE; ENERGY-CONSUMPTION; WALL INSULATION; BUILDINGS; COEFFICIENT; SIMULATION; THICKNESS;
D O I
10.1016/j.solener.2020.03.074
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In present energy conservation design, air-conditioning operation is deemed to be continuous in the whole building, but the intermittent operation of air-conditioning is widely applied due to the occupant's behaviour. The large discrepancy in the energy efficiency and energy consumption can cause between the actual usage and the primary design. Considering this situation, a numerical simulation was carried on to optimize the thermal performance of non-transparent envelope components in three typical rooms with air-conditioning under the intermittent operation in summer. The energy-saving potential of all components was analysed, while the whole heat transfer capacities in three typical rooms were compared between traditional and optimized envelopes. Results showed by optimizing envelope components, the average heat flow values could be reduced by up to 13.78-71.27%, while the average heat transfer capacities were reduced by 33-39% and their fluctuation percentages were also decreased obviously. Compared to interior and exterior walls, floors and ceilings had the higher energy-saving contribution percentages of 35-80% and the larger the room area, the larger the energy-saving contribution percentage of floors and ceilings.
引用
收藏
页码:798 / 809
页数:12
相关论文
共 43 条
  • [1] Composition of cooling load formed by non-transparent envelopes of a common office building under air-conditioning intermittent operation
    Meng, Xi
    Shi, Xinyu
    Gao, Yanna
    Luo, Tao
    JOURNAL OF BUILDING PHYSICS, 2020, 43 (06) : 528 - 544
  • [2] Thermal comfort in an office with intermittent air-conditioning operation
    Xu, X. G.
    Sit, K. Y.
    Deng, S. M.
    Chan, M. Y.
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2010, 31 (01): : 91 - 100
  • [3] Formation analysis of cooling load from envelopes under air-conditioning intermittent operation
    Guan, Yifan
    Hu, Chenxi
    Meng, Xi
    SOLAR ENERGY, 2025, 292
  • [4] Thermal performance optimization of building floors under air-conditioning intermittent operation by numerical simulation
    Meng, Xi
    Du, Junfei
    Wang, Yating
    Gao, Yanna
    JOURNAL OF BUILDING PHYSICS, 2019, 43 (02) : 99 - 120
  • [5] Influence of air-conditioning intermittent operation on the cooling in
    Meng, Xi
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 58
  • [6] Qualitative analysis of the cooling load in the typical room under continuous and intermittent runnings of air-conditioning
    Zhang, Lili
    Wang, Yating
    Meng, Xi
    Li, Jialun
    Sun, Nan
    Hou, Jiawen
    Long, Enshen
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 405 - 409
  • [7] A systemic review to improve the intermittent operation efficiency of air-conditioning and heating system
    Hu, Chenxi
    Xu, Ruoyi
    Meng, Xi
    JOURNAL OF BUILDING ENGINEERING, 2022, 60
  • [8] Effect of inner decoration coating on inner surface temperatures and heat flows under air-conditioning intermittent operation
    Meng, Xi
    Du, Junfei
    Gao, Yanna
    Yu, Hanting
    CASE STUDIES IN THERMAL ENGINEERING, 2019, 14
  • [9] Effect of the insulation materials filling on the thermal performance of sintered hollow bricks under the air-conditioning intermittent operation
    Hou, Chaoping
    Meng, Xi
    Gao, Yanna
    Mao, Wei
    Long, Enshen
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2018, 8 : 217 - 225
  • [10] Comparative analysis on thermal performance of different wall insulation forms under the air-conditioning intermittent operation in summer
    Meng, Xi
    Luo, Tao
    Gao, Yanna
    Zhang, Lili
    Huang, Xing
    Hou, Chaoping
    Shen, Qiong
    Long, Enshen
    APPLIED THERMAL ENGINEERING, 2018, 130 : 429 - 438