Ablation Index Guided Left Atrial Posterior Wall Isolation Analysis with Different Target Ablation Index Values

被引:1
|
作者
Makihara, Yu [1 ]
Miyazaki, Shinsuke [2 ]
Harama, Tomoko [1 ]
Obunai, Kotaro [1 ]
Watanabe, Hiroyuki [1 ]
Tada, Hiroshi [2 ]
机构
[1] Tokyo Bay Urayasu Ichikawa Med Ctr, Dept Cardiol, 3-4-32 Todaijima, Urayasu, Chiba 2790001, Japan
[2] Univ Fukui, Fac Med Sci, Dept Cardiovasc Med, Fukui, Japan
关键词
Catheter ablation; Linear ablation; Radiofrequency; PULMONARY VEIN ISOLATION;
D O I
10.1536/ihj.22-091
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Ablation index (AI)-guided linear ablation is reported to be feasible. We assessed the feasibility of AI-guided left atrial (LA) posterior wall isolations (PWIs) using different tar-get AI values. Seventy-one persistent atrial fibrillation patients who underwent AI-guided PWIs following pulmonary vein isolation were included. LA linear lesions were created with strict contiguity (inter-lesion distance < 4 mm) and different predetermined AI target values (Group-1: 430, Group-2: 450). The data was analyzed retrospectively. The total radiofrequency application time of the roof and bottom-line ablation was a median of 2.8 (2.0, 3.8) and 3.6 (2.8, 4.3) minutes. The first-pass PWI success rate (26/35 [74.3%] versus 16/36 [44.4%], P = 0.011) and a first-pass roof line block (28/35 [80.0%] versus 21/36 [58.3%], P = 0.048) were significantly higher in Group-2 than Group-1, but that for the first-pass bottom line block was similar between Group-1 and Group-2 (29/36 [80.6%] versus 29/35 [82.9%], P = 0.80). Successful PWIs were achieved by additional applications in all. The significant parameter associated with a successful first-pass LA roof line block was a greater RF power, and that for the LA bottom were a higher radiofrequency power and shorter inter-lesion distance. Conduction gaps were mostly located at the middle of both lines. Among 22 roof line gaps, 12 were closed on the line whereas 10 (45.4%) required ablation inside the posterior wall for PWIs. On the contrary, all 11 gaps on bottom lines were closed on the line. Successful first-pass PWIs were obtained in 74% of patients using a target AI value of 450 and strict criteria for the lesion contiguity.
引用
收藏
页码:708 / 715
页数:8
相关论文
共 50 条
  • [21] Left atrial posterior wall isolation during pulse field ablation in patients with persistent atrial fibrillation
    Moltrasio, Massimo
    Solimene, Francesco
    Casella, Michela
    Schiavone, Marco
    Bianchi, Stefano
    Iacopino, Saverio
    Rossillo, Antonio
    Schillaci, Vincenzo
    Filannino, Pasquale
    Maggio, Ruggero
    Themistoklakis, Sakis
    Pandozi, Claudio
    Malacrida, Maurizio
    Dello Russo, Antonio
    Tondo, Claudio
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024, 35 (06) : 1289 - 1289
  • [22] Challenges and Outcomes of Posterior Wall Isolation for Ablation of Atrial Fibrillation
    Kumar, Prabhat
    Bamimore, Ayotunde M.
    Schwartz, Jennifer D.
    Chung, Eugene H.
    Gehi, Anil K.
    Kiser, Andy C.
    Hummel, James P.
    Mounsey, J. Paul
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (09):
  • [23] The role of left atrium posterior wall isolation in patients undergoing catheter ablation for atrial fibrillation
    Song, Zheng-Qi
    Lu, Xin-Yu
    Xu, Yu-Peng
    Lin, Hui
    Chen, Yi-He
    JOURNAL OF CARDIOLOGY, 2025, 85 (03) : 213 - 219
  • [24] Ablation index-guided high-power ablation for superior vena cava isolation in patients with atrial fibrillation
    Cui, Luqian
    Cui, Shihua
    Dong, Shujuan
    Li, Jingchao
    Yu, Haijia
    Song, Huihui
    Han, Yongmei
    Chu, Yingjie
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [25] Efficacy and Safety Ablation Index-Guided High-Energy Linear Ablation for Persistent Atrial Fibrillation: PVI Plus Linear Ablation of Mitral Isthmus and Posterior Box Isolation
    Li, Xi
    Liu, Tao
    Cui, Bo
    Zhang, Jinlin
    Chen, Yanhong
    Wu, Gang
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (02)
  • [26] Tailored ablation index based on left atrial wall thickness assessed by computed tomography for pulmonary vein isolation in patients with atrial fibrillation
    Lee, So-Ryoung
    Park, Hyoung-Seob
    Kwon, Soonil
    Choi, Eue-Keun
    Oh, Seil
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (09) : 1811 - 1819
  • [27] Multiple procedure outcomes for nonparoxysmal atrial fibrillation: Left atrial posterior wall isolation versus stepwise ablation
    Barbhaiya, Chirag R.
    Knotts, Robert J.
    Beccarino, Nicholas
    Vargas-Pelaez, Alvaro F.
    Jankelson, Lior
    Bernstein, Scott
    Park, David
    Holmes, Douglas
    Aizer, Anthony
    Chinitz, Larry A.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (12) : 3117 - 3123
  • [28] Is Incomplete Left Atrial Posterior Wall Isolation Associated With Recurrence of Atrial Fibrillation After Radiofrequency Catheter Ablation?
    Fujito, Takefumi
    Kamiyama, Naoyuki
    Mochizuki, Atsushi
    Nagahara, Daigo
    Miura, Tetsuji
    CIRCULATION, 2019, 140
  • [29] Comparison of Cryoballoon and Ablation Index-Guided Radiofrequency Ablation in Paroxysmal Atrial Fibrillation
    Bocz, Botond
    Debreceni, Dorottya
    Janosi, Kristof-Ferenc
    Torma, Dalma
    Kupo, Peter
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (06)
  • [30] Impact of left atrial posterior wall isolation on arrhythmia outcomes in patients with atrial fibrillation undergoing repeat ablation
    Pothineni, Naga Venkata K.
    Lin, Aung
    Frankel, David S.
    Supple, Gregory E.
    Garcia, Fermin C.
    Lin, David
    Hyman, Matthew C.
    Kumareswaran, Ramanan
    Arkles, Jeffrey
    Riley, Michael
    Deo, Rajat
    Epstein, Andrew E.
    Nazarian, Saman
    Schaller, Robert D.
    Callans, David J.
    Marchlinski, Francis E.
    Santangeli, Pasquale
    Dixit, Sanjay
    HEART RHYTHM O2, 2021, 2 (05): : 489 - 497