Ablation index-guided high-power ablation for superior vena cava isolation in patients with atrial fibrillation

被引:3
|
作者
Cui, Luqian [1 ]
Cui, Shihua [2 ]
Dong, Shujuan [1 ]
Li, Jingchao [1 ]
Yu, Haijia [1 ]
Song, Huihui [1 ]
Han, Yongmei [1 ]
Chu, Yingjie [1 ]
机构
[1] Henan Prov Peoples Hosp, Dept Cardiol, Zhengzhou, Peoples R China
[2] Dalian Med Univ, Dalian, Peoples R China
来源
关键词
ablation index; high-power ablation; superior vena cava isolation; atrial fibrillation; cardiac electrophysiology; PULMONARY VEIN ISOLATION; CATHETER ABLATION; IMPACT; INITIATION; INJURY;
D O I
10.3389/fcvm.2022.1033297
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe strategy of ablation index (AI)-guided high-power ablation seems to be a novel strategy for performing pulmonary vein isolation (PVI). An AI-guided high-power ablation strategy was used in this study to determine whether superior vena cava isolation (SVCI) after PVI was feasible and safe for patients with AF. MethodsData from 53 patients with AF were collected. Mapping and ablation of SVC were performed. The applied power was set at 45 W and the procedure was guided by AI. The SVC was divided into six segments in a cranial view. The RF applications and AI values in different segments were compared and analyzed. Using receiver operating characteristic (ROC) analysis, the diagnostic accuracy of AI value for predicting segment block was evaluated. ResultsElectrical SVCIs were successfully achieved in all patients. SVCI was performed by segment ablation in most cases, with RF applications in different segments. The mean AI value in non-lateral walls was higher than that of the lateral wall (392 +/- 28 vs. 371 +/- 37, P < 0.001). Acutely blocked sites had significantly larger AI values compared with no-blocked sites (390 +/- 30 vs. 343 +/- 23, P < 0.001). The optimal AI cut-off value for non-lateral segments was 379 (sensitivity: 75.9%, specificity: 100%) and for lateral segments was 345 (sensitivity: 82.3%, specificity: 100%). ConclusionThe AI values were predictive of the acute conduction block of SVCI. With AI values of 345 and 379, respectively, conduction block was achieved in the lateral walls at a lower level than in the non-lateral walls.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Safety and efficacy of ablation index-guided high-power ablation for the treatment of atrial fibrillation
    Zhu, Jing
    Lin, Xian-he
    HELIYON, 2023, 9 (04)
  • [2] The importance of superior vena cava isolation in ablation strategy for atrial fibrillation
    Higuchi, Koji
    Yamauchi, Yasuteru
    Hirao, Kenzo
    Marrouche, Nassir F.
    CURRENT OPINION IN CARDIOLOGY, 2013, 28 (01) : 2 - 6
  • [3] Lesion Size Index-guided high-power ablation for atrial fibrillation: Opening the therapeutic window
    Hanley, Alan
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (05) : 1312 - 1313
  • [4] Ablation index-guided ablation with milder targets for atrial fibrillation: Comparison between high power and low power ablation
    Liu, Zheng
    Liu, Li-feng
    Liu, Xiao-qin
    Liu, Jiapeng
    Wang, Yu-xin
    Liu, Ye
    Liu, Xing-peng
    Yang, Xin-chun
    Chen, Mu-lei
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [5] Electrical isolation of the superior vena cava by laser balloon ablation in patients with atrial fibrillation
    Arceluz, Martin R.
    Cruz, Pedro F.
    Falconi, Estela
    Montes de Oca, Rosa
    Delgado, Reina
    Figueroa, Jorge
    Ortega, Marta
    Merino, Jose L.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 53 (02) : 217 - 223
  • [6] Electrical isolation of the superior vena cava by laser balloon ablation in patients with atrial fibrillation
    Martín R. Arceluz
    Pedro F. Cruz
    Estela Falconi
    Rosa Montes de Oca
    Reina Delgado
    Jorge Figueroa
    Marta Ortega
    José L. Merino
    Journal of Interventional Cardiac Electrophysiology, 2018, 53 : 217 - 223
  • [7] Empirical superior vena cava electrical isolation guided by quantitative ablation index improves outcomes of radiofrequency catheter ablation for paroxysmal atrial fibrillation
    Guan, Wenchi
    Liu, Jun
    Chen, Keping
    Yao, Yan
    OPEN HEART, 2024, 11 (02):
  • [8] Efficacy of ablation index-guided pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Jiang, Ruhong
    Chen, Minglong
    Fan, Jie
    Yi, Fu
    Tang, Anli
    Liu, Xingpeng
    Zhu, Wenqing
    Liu, Shaowen
    Huang, Xiaobo
    Liu, Qiang
    Ju, Weizhu
    Zhang, Xi
    Li, Jie
    He, Jiangui
    Shi, Liang
    Zhou, Genqing
    Wang, Yuegang
    Fu, Guosheng
    Jiang, Chenyang
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2022, 45 (10): : 1186 - 1193
  • [9] Safety and efficacy of ablation index-guided atrial fibrillation ablation in octogenarians
    Okamatsu, Hideharu
    Okumura, Ken
    Onishi, Fumitaka
    Yoshimura, Akino
    Negishi, Kodai
    Tsurugi, Takuo
    Tanaka, Yasuaki
    Nakao, Koichi
    Sakamoto, Tomohiro
    Koyama, Junjiro
    CLINICAL CARDIOLOGY, 2023, 46 (07) : 794 - 800
  • [10] Efficacy and safety of segmental radiofrequency ablation for isolation of the superior vena cava in patients with atrial fibrillation
    陈英伟
    China Medical Abstracts(Internal Medicine), 2021, 38 (03) : 161 - 162