Ablation index-guided high-power ablation for superior vena cava isolation in patients with atrial fibrillation

被引:3
|
作者
Cui, Luqian [1 ]
Cui, Shihua [2 ]
Dong, Shujuan [1 ]
Li, Jingchao [1 ]
Yu, Haijia [1 ]
Song, Huihui [1 ]
Han, Yongmei [1 ]
Chu, Yingjie [1 ]
机构
[1] Henan Prov Peoples Hosp, Dept Cardiol, Zhengzhou, Peoples R China
[2] Dalian Med Univ, Dalian, Peoples R China
来源
关键词
ablation index; high-power ablation; superior vena cava isolation; atrial fibrillation; cardiac electrophysiology; PULMONARY VEIN ISOLATION; CATHETER ABLATION; IMPACT; INITIATION; INJURY;
D O I
10.3389/fcvm.2022.1033297
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundThe strategy of ablation index (AI)-guided high-power ablation seems to be a novel strategy for performing pulmonary vein isolation (PVI). An AI-guided high-power ablation strategy was used in this study to determine whether superior vena cava isolation (SVCI) after PVI was feasible and safe for patients with AF. MethodsData from 53 patients with AF were collected. Mapping and ablation of SVC were performed. The applied power was set at 45 W and the procedure was guided by AI. The SVC was divided into six segments in a cranial view. The RF applications and AI values in different segments were compared and analyzed. Using receiver operating characteristic (ROC) analysis, the diagnostic accuracy of AI value for predicting segment block was evaluated. ResultsElectrical SVCIs were successfully achieved in all patients. SVCI was performed by segment ablation in most cases, with RF applications in different segments. The mean AI value in non-lateral walls was higher than that of the lateral wall (392 +/- 28 vs. 371 +/- 37, P < 0.001). Acutely blocked sites had significantly larger AI values compared with no-blocked sites (390 +/- 30 vs. 343 +/- 23, P < 0.001). The optimal AI cut-off value for non-lateral segments was 379 (sensitivity: 75.9%, specificity: 100%) and for lateral segments was 345 (sensitivity: 82.3%, specificity: 100%). ConclusionThe AI values were predictive of the acute conduction block of SVCI. With AI values of 345 and 379, respectively, conduction block was achieved in the lateral walls at a lower level than in the non-lateral walls.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Index-Guided High-Power Radiofrequency Catheter Ablation for Atrial Fibrillation: A Systematic Review and Meta-Analysis Study
    Yoga Waranugraha
    Chia-Ti Tsai
    Lian-Yu Lin
    Current Cardiology Reports, 2023, 25 : 1397 - 1414
  • [22] Index-Guided High-Power Radiofrequency Catheter Ablation for Atrial Fibrillation: A Systematic Review and Meta-Analysis Study
    Waranugraha, Yoga
    Tsai, Chia-Ti
    Lin, Lian-Yu
    CURRENT CARDIOLOGY REPORTS, 2023, 25 (11) : 1397 - 1414
  • [23] Optimal interlesion distance in ablation index-guided pulmonary vein isolation for atrial fibrillation
    Kobayashi, Shuhei
    Fukaya, Hidehira
    Oikawa, Jun
    Saito, Daiki
    Sato, Tetsuro
    Matsuura, Gen
    Arakawa, Yuki
    Shirakawa, Yuki
    Nishinarita, Ryo
    Horiguchi, Ai
    Ishizue, Naruya
    Kishihara, Jun
    Niwano, Shinichi
    Ako, Junya
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (01) : 123 - 131
  • [24] Optimal interlesion distance in ablation index-guided pulmonary vein isolation for atrial fibrillation
    Shuhei Kobayashi
    Hidehira Fukaya
    Jun Oikawa
    Daiki Saito
    Tetsuro Sato
    Gen Matsuura
    Yuki Arakawa
    Yuki Shirakawa
    Ryo Nishinarita
    Ai Horiguchi
    Naruya Ishizue
    Jun Kishihara
    Shinichi Niwano
    Junya Ako
    Journal of Interventional Cardiac Electrophysiology, 2021, 62 : 123 - 131
  • [25] Ablation index-guided high-power vs. moderate-power cavotricuspid isthmus ablation
    Chikata, Akio
    Kato, Takeshi
    Usuda, Kazuo
    Fujita, Shuhei
    Maruyama, Michiro
    Otowa, Kanichi
    Usuda, Keisuke
    Kusayama, Takashi
    Tsuda, Toyonobu
    Hayashi, Kenshi
    Takamura, Masayuki
    HEART AND VESSELS, 2023, 38 (01) : 90 - 95
  • [26] Ablation of Persistent Left Superior Vena Cava in Atrial Fibrillation Case
    Zhang, Shuang
    Chen, Mingxian
    Xiao, Yichao
    Hu, Lin
    Tang, Hanze
    Liao, Liyi
    Li, Xuping
    CLINICAL CASE REPORTS, 2024, 12 (12):
  • [27] Ablation index-guided high-power vs. moderate-power cavotricuspid isthmus ablation
    Akio Chikata
    Takeshi Kato
    Kazuo Usuda
    Shuhei Fujita
    Michiro Maruyama
    Kanichi Otowa
    Keisuke Usuda
    Takashi Kusayama
    Toyonobu Tsuda
    Kenshi Hayashi
    Masayuki Takamura
    Heart and Vessels, 2023, 38 : 90 - 95
  • [28] Case Report: Successful Ablation of Atrial Fibrillation by stepwise Mapping and Isolation of the Superior vena cava
    Petzl, Adrian
    Kollias, Georgios
    Derndorfer, Michael
    Moroka, Kgomotso
    Martinek, Martin
    Aichinger, Josef
    Puererfellner, Helmut
    WIENER KLINISCHE WOCHENSCHRIFT, 2019, 131 : 355 - 356
  • [29] Catheter ablation of atrial fibrillation originating from superior vena cava
    Li, JT
    Wang, LX
    ARCHIVES OF MEDICAL RESEARCH, 2006, 37 (03) : 415 - 418
  • [30] Actual tissue temperature during ablation index-guided high-power short-duration ablation versus standard ablation: Implications in terms of the efficacy and safety of atrial fibrillation ablation
    Otsuka, Naoto
    Okumura, Yasuo
    Kuorkawa, Sayaka
    Nagashima, Koichi
    Wakamatsu, Yuji
    Hayashida, Satoshi
    Ohkubo, Kimie
    Nakai, Toshiko
    Hao, Hiroyuki
    Takahashi, Rie
    Taniguchi, Yoshiki
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (01) : 55 - 63