Handheld fetal Doppler device for assessing heart rate in neonatal resuscitation

被引:8
|
作者
Shimabukuro, Rinshu [1 ,2 ]
Takase, Kozo [2 ]
Ohde, Sachiko [3 ]
Kusakawa, Isao [1 ]
机构
[1] Tokyo Med & Dent Univ, St Lukes Int Hosp, Dept Pediat, Tokyo, Japan
[2] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Div Publ Hlth, Dept Res Dev, Tokyo, Japan
[3] St Lukes Int Univ, Grad Sch Publ Hlth, Planning Off, Ctr Clin Epidemiol, Tokyo, Japan
关键词
electrocardiogram; fetal Doppler; heart rate; neonate; resuscitation; OXIMETRY;
D O I
10.1111/ped.13374
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
BackgroundThe use of neonatal three-lead electrocardiograms (Neo-ECG) is suggested for the assessment of heart rate (HR) in neonatal resuscitation, but primary childbirth facilities (i.e. maternity clinics or maternity homes) are not sufficiently equipped for this. The aim of this study was to therefore to confirm the potential of a handheld fetal Doppler device (FDD), widely used to assess HR in labor room resuscitation, and to compare its equivalency to Neo-ECG. MethodsIn low-risk full-term infants, HR was measured five times per minute in minutes 1-5 after delivery using the FDD and Neo-ECG, and their equivalence compared. The equivalence margin was set at a HR difference of <5 beats/min and <5%. Moreover, the times at which HR was displayed were measured for both methods. ResultsFDD and Neo-ECG HR correlated strongly (r = 0.977) in 155 measurements in 33 cases. The mean HR difference was -0.123 beats/min (95%CI: -0.594 to +0.345), and the logarithmic transformation of the HR ratio was -0.0003 (95%CI: -0.0020 to +0.0015). The mean HR difference and HR ratio were within the equivalence margin. For HR assessment using the FDD, 155 of 165 measurements (93.9%) could be obtained in <10 s. ConclusionsIn HR assessment, FDD is a valid substitute for Neo-ECG in primary childbirth facilities that are not sufficiently equipped for Neo-ECG.
引用
收藏
页码:1069 / 1073
页数:5
相关论文
共 50 条
  • [41] Robust estimation of fetal heart rate variability using Doppler ultrasound
    Fernando, KL
    Mathews, VJ
    Varner, MW
    Clark, EB
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (08) : 950 - 957
  • [42] Doppler Parameters Predicting Fetal Heart Rate Abnormalities in Diabetic Pregnancies
    Pawelec, Malgorzata
    Karmowski, Andrzej
    Krzemieniewska, Joanna
    Kaniak, Marek
    Karmowski, Mikolaj
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2009, 18 (05): : 481 - 486
  • [43] Fetal pulse oximetry:: Correlation with intrapartum fetal heart rate patterns and neonatal outcome
    Tekin, Arzu
    Oezkan, Sebiha
    Caliskan, Eray
    Oezeren, Semih
    Corakci, Aydin
    Yuecesoy, Izzet
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2008, 34 (05) : 824 - 831
  • [44] The Analysis of Sleep Stages with Motion and Heart Rate Signals from a Handheld Wearable Device
    Lee, Seungmin
    Nam, Seungyoon
    Shin, Hyunsoon
    2016 INTERNATIONAL CONFERENCE ON INFORMATION AND COMMUNICATION TECHNOLOGY CONVERGENCE (ICTC 2016): TOWARDS SMARTER HYPER-CONNECTED WORLD, 2016, : 1135 - 1137
  • [45] Heart Rate at One Minute Impact Neonatal Resuscitation & Clinical Outcomes in Infants
    Kumar, Vasantha H.
    Skrobacz, Annie
    Ma, Changxing
    CIRCULATION, 2016, 134
  • [46] FETAL AND NEONATAL CARDIAC ASSESSMENT WITH DOPPLER
    REED, KL
    SEMINARS IN PERINATOLOGY, 1987, 11 (04) : 347 - 356
  • [47] Diagnostic Accuracy of Fetal Heart Rate Monitoring in the Identification of Neonatal Encephalopathy
    Graham, Ernest M.
    Adami, Rebecca R.
    McKenney, Stephanie L.
    Jennings, Jacky M.
    Burd, Irina
    Witter, Frank R.
    OBSTETRICS AND GYNECOLOGY, 2014, 124 (03): : 507 - 513
  • [48] NEONATAL DEPRESSION AND FETAL HEART-RATE PATTERNS DURING LABOR
    OGURECK, JE
    NEUMAN, MR
    ROUX, JF
    OBSTETRICS AND GYNECOLOGY, 1972, 40 (03): : 347 - &
  • [49] INTRAPARTUM FETAL HEART-RATE PATTERNS AND NEONATAL INTRAVENTRICULAR HEMORRHAGE
    RAYBURN, WF
    JOHNSON, MZ
    HOFFMAN, KL
    DONN, SM
    NELSON, RM
    AMERICAN JOURNAL OF PERINATOLOGY, 1987, 4 (02) : 98 - 101
  • [50] Computerized analysis of fetal heart rate signals as the predictor of neonatal acidemia
    Czabanski, R.
    Jezewski, J.
    Matonia, A.
    Jezewski, M.
    EXPERT SYSTEMS WITH APPLICATIONS, 2012, 39 (15) : 11846 - 11860