Handheld fetal Doppler device for assessing heart rate in neonatal resuscitation

被引:8
|
作者
Shimabukuro, Rinshu [1 ,2 ]
Takase, Kozo [2 ]
Ohde, Sachiko [3 ]
Kusakawa, Isao [1 ]
机构
[1] Tokyo Med & Dent Univ, St Lukes Int Hosp, Dept Pediat, Tokyo, Japan
[2] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Div Publ Hlth, Dept Res Dev, Tokyo, Japan
[3] St Lukes Int Univ, Grad Sch Publ Hlth, Planning Off, Ctr Clin Epidemiol, Tokyo, Japan
关键词
electrocardiogram; fetal Doppler; heart rate; neonate; resuscitation; OXIMETRY;
D O I
10.1111/ped.13374
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
BackgroundThe use of neonatal three-lead electrocardiograms (Neo-ECG) is suggested for the assessment of heart rate (HR) in neonatal resuscitation, but primary childbirth facilities (i.e. maternity clinics or maternity homes) are not sufficiently equipped for this. The aim of this study was to therefore to confirm the potential of a handheld fetal Doppler device (FDD), widely used to assess HR in labor room resuscitation, and to compare its equivalency to Neo-ECG. MethodsIn low-risk full-term infants, HR was measured five times per minute in minutes 1-5 after delivery using the FDD and Neo-ECG, and their equivalence compared. The equivalence margin was set at a HR difference of <5 beats/min and <5%. Moreover, the times at which HR was displayed were measured for both methods. ResultsFDD and Neo-ECG HR correlated strongly (r = 0.977) in 155 measurements in 33 cases. The mean HR difference was -0.123 beats/min (95%CI: -0.594 to +0.345), and the logarithmic transformation of the HR ratio was -0.0003 (95%CI: -0.0020 to +0.0015). The mean HR difference and HR ratio were within the equivalence margin. For HR assessment using the FDD, 155 of 165 measurements (93.9%) could be obtained in <10 s. ConclusionsIn HR assessment, FDD is a valid substitute for Neo-ECG in primary childbirth facilities that are not sufficiently equipped for Neo-ECG.
引用
收藏
页码:1069 / 1073
页数:5
相关论文
共 50 条
  • [21] CORRELATION OF FETAL HEART-RATE PATTERNS AND FETAL PH WITH NEONATAL OUTCOME
    TEJANI, N
    MANN, LI
    BHAKTHAVATHSALAN, A
    OBSTETRICS AND GYNECOLOGY, 1976, 48 (04): : 460 - 463
  • [22] Neonatal outcomes and resuscitation practices following the addition of heart rate-guidance to basic resuscitation
    Patterson, Jackie K.
    Ishoso, Daniel
    Lokangaka, Adrien
    Iyer, Pooja
    Lowman, Casey
    Eilevstjonn, Joar
    Haug, Ingunn
    Kamath-Rayne, Beena D.
    Mafuta, Eric
    Myklebust, Helge
    Nolen, Tracy
    Tshefu, Antoinette
    Bose, Carl
    Berkelhamer, Sara
    PLOS ONE, 2025, 20 (01):
  • [23] Fetal heart rate parameters predictive of neonatal outcome in the presence of fetal bradycardia
    Williams, K
    Galerneau, F
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2001, 185 (06) : S130 - S130
  • [24] Fetal heart rate and maternal heart rate confusion during intrapartum monitoring: comparison of transabdominal fetal ECG and Doppler telemetry
    Signaroldi, Maria
    Mastroianni, Cristina
    Rosti, Eleonora
    Loi, Giorgia
    Di Francesco, Stefania
    Ferrazzi, Enrico
    Stampalija, Tamara
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2011, 204 : S261 - S262
  • [25] Fetal heart rate variability analysis for neonatal acidosis prediction
    Gatellier, M-A
    De Jonckheere, J.
    Storme, L.
    Houfflin-Debarge, V
    Ghesquiere, L.
    Garabedian, C.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2021, 35 (04) : 771 - 777
  • [26] Fetal heart rate variability analysis for neonatal acidosis prediction
    M.-A. Gatellier
    J. De Jonckheere
    L. Storme
    V. Houfflin-Debarge
    L. Ghesquiere
    C. Garabedian
    Journal of Clinical Monitoring and Computing, 2021, 35 : 771 - 777
  • [27] Which fetal heart rate characteristics are associated with neonatal encephalopathy?
    Frey, Heather
    Liu, Xiaohua
    Lynch, Courtney D.
    Musindi, Wanjiku
    Samuels, Philip
    Rood, Kara M.
    Thung, Stephen F.
    Machicao, Juliana
    Cheng, Weiwei
    Landon, Mark B.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2017, 216 (01) : S398 - S399
  • [28] Intrapartum fetal heart rate patterns in the prediction of neonatal acidemia
    Williams, KP
    Galerneau, F
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2003, 188 (03) : 820 - 823
  • [29] Terminal Fetal Heart Rate Decelerations and Neonatal Outcomes Reply
    Cahill, Alison G.
    Caughey, Aaron B.
    OBSTETRICS AND GYNECOLOGY, 2014, 123 (04): : 887 - 887
  • [30] Association of Fetal Heart Rate Baseline Change and Neonatal Outcomes
    Yang, Michael
    Stout, Molly J.
    Lopez, Julia D.
    Colvin, Ryan
    Macones, George A.
    Cahill, Alison G.
    AMERICAN JOURNAL OF PERINATOLOGY, 2017, 34 (09) : 879 - 886