Handheld fetal Doppler device for assessing heart rate in neonatal resuscitation

被引:8
|
作者
Shimabukuro, Rinshu [1 ,2 ]
Takase, Kozo [2 ]
Ohde, Sachiko [3 ]
Kusakawa, Isao [1 ]
机构
[1] Tokyo Med & Dent Univ, St Lukes Int Hosp, Dept Pediat, Tokyo, Japan
[2] Tokyo Med & Dent Univ, Grad Sch Med & Dent Sci, Div Publ Hlth, Dept Res Dev, Tokyo, Japan
[3] St Lukes Int Univ, Grad Sch Publ Hlth, Planning Off, Ctr Clin Epidemiol, Tokyo, Japan
关键词
electrocardiogram; fetal Doppler; heart rate; neonate; resuscitation; OXIMETRY;
D O I
10.1111/ped.13374
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
BackgroundThe use of neonatal three-lead electrocardiograms (Neo-ECG) is suggested for the assessment of heart rate (HR) in neonatal resuscitation, but primary childbirth facilities (i.e. maternity clinics or maternity homes) are not sufficiently equipped for this. The aim of this study was to therefore to confirm the potential of a handheld fetal Doppler device (FDD), widely used to assess HR in labor room resuscitation, and to compare its equivalency to Neo-ECG. MethodsIn low-risk full-term infants, HR was measured five times per minute in minutes 1-5 after delivery using the FDD and Neo-ECG, and their equivalence compared. The equivalence margin was set at a HR difference of <5 beats/min and <5%. Moreover, the times at which HR was displayed were measured for both methods. ResultsFDD and Neo-ECG HR correlated strongly (r = 0.977) in 155 measurements in 33 cases. The mean HR difference was -0.123 beats/min (95%CI: -0.594 to +0.345), and the logarithmic transformation of the HR ratio was -0.0003 (95%CI: -0.0020 to +0.0015). The mean HR difference and HR ratio were within the equivalence margin. For HR assessment using the FDD, 155 of 165 measurements (93.9%) could be obtained in <10 s. ConclusionsIn HR assessment, FDD is a valid substitute for Neo-ECG in primary childbirth facilities that are not sufficiently equipped for Neo-ECG.
引用
收藏
页码:1069 / 1073
页数:5
相关论文
共 50 条
  • [1] Heart-rate evaluation using fetal ultrasonic Doppler during neonatal resuscitation
    Kayama, Kazunori
    Hosono, Shigeharu
    Yoshikawa, Kayo
    Kato, Ryota
    Seimiya, Ayako
    Fuwa, Kazumasa
    Hijikata, Midori
    Aoki, Ryoji
    Okahashi, Aya
    Nagano, Nobuhiko
    Morioka, Ichiro
    PEDIATRICS INTERNATIONAL, 2020, 62 (08) : 926 - 931
  • [2] Measurement of neonatal heart rate using handheld Doppler ultrasound
    Dyson, Amanda
    Jeffrey, Michele
    Kluckow, Martin
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2017, 102 (02): : F116 - F119
  • [3] Ultrasonic Pocket Doppler, novel technology for fetal and neonatal heart rate assessment
    Zanardo, Vincenzo
    Parotto, Matteo
    RESUSCITATION, 2019, 145 : 91 - 92
  • [4] A test and simulation device for Doppler-based fetal heart rate monitoring
    Mert, Ahmet
    Sezdi, Mana
    Akan, Aydin
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2015, 23 (04) : 1187 - 1194
  • [5] Heart Rate Assessment during Neonatal Resuscitation
    Johnson, Peter A.
    Schmolzer, Georg M.
    HEALTHCARE, 2020, 8 (01)
  • [6] Strengthening Fetal Heart Rate Monitoring during Labor with a Standard Handheld Doppler - Implementation Experience from India
    Bajpayee, Devina
    Sarin, Enisha
    Dastidar, Sourav Ghosh
    Chandra, Subodh
    Mohanty, Jaya Swarup
    Bisht, Nitin
    Kumar, Arvind
    Kumar, Harish
    INDIAN JOURNAL OF COMMUNITY MEDICINE, 2022, 47 (03) : 405 - 409
  • [7] FETAL HEART-RATE AND DOPPLER SONOGRAPHY
    WEISS, E
    GYNAKOLOGE, 1994, 27 (03): : 146 - 150
  • [9] Maternal, fetal and neonatal heart rate and heart rate variability in Holstein cattle
    Quevedo, Dario A. C.
    Lourenco, Maria Lucia G.
    Bolanos, Carmen D.
    Alfonso, Angelica
    Ulian, Carla M. V.
    Chiacchio, Simone B.
    PESQUISA VETERINARIA BRASILEIRA, 2019, 39 (04): : 286 - 291
  • [10] Fetal Heart Rate Monitoring Casebook: Checkmark Fetal Heart Rate Pattern and Normal Neonatal Outcome
    Martin Gimovsky
    Boris Petrikovsky
    Craig C Linder
    Elizabeth Schneider
    Journal of Perinatology, 1999, 19 (7) : 541 - 542