Validation of a gas chromatography/mass spectrometry method for the quantification of aerosolized Jet Propellant 8

被引:19
|
作者
Dietzel, KD [1 ]
Campbell, JL [1 ]
Bartlett, MG [1 ]
Witten, ML [1 ]
Fisher, JW [1 ]
机构
[1] Univ Georgia, Dept Environm Hlth Sci, Interdisciplinary Toxicol Program, Athens, GA 30602 USA
关键词
JP-8; GC/MS; hydrocarbon analysis; jet fuel; inhalation studies;
D O I
10.1016/j.chroma.2005.07.049
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Jet Propellant 8 (JP-8) jet fuel is a kerosene-based fuel containing hundreds of hydrocarbons used by the military in NATO countries. Previous rodent inhalation studies carried out with aerosolized JP-8 never evaluated the exposure chamber atmosphere. For this reason, our laboratory developed an analytical method, with an accuracy of better than 80% and precision of better than 20%, for JP-8 aerosol and vapor samples using gas chromatography/mass spectrometry (GC/MS). A method was developed for quantification of selected individual components of JP-8 and for the total amount of JP-8 in aerosolized fuel. A 34 component surrogate hydrocarbon mixture (SHM) was developed and used for simultaneous analysis of the individual components. Three separate runs containing a standard curve and five replicates each at the selected concentrations were analyzed for both the SHM and neat JP-8. The resulting interday accuracy (100 - percent relative error) and precision (relative standard deviation) values for the SHM were 86.5% or better and 8.0% or better, respectively. The intraday accuracy and precision values ranged from 99.29% to 84.50% and 0.97% to 12.4%, respectively. For the total amount of JP-8 in aerosol and vapor, the interday accuracy was 83.7% or better and interday precision was 7.0% or better. The intraday accuracy and precision values ranged from 94.8% to 80.4% and 2.4% to 10.5%, respectively. We then used this method to analyze samples collected from an inhalation chamber. From the data obtained, we are able to account for approximately 40-44% of the mass of the aerosol portion and 68-70% of the mass of the vapor portion. The aerosol represented 6-10% of the total mass of the aerosolized JP-8 fuel with the remaining portion being the vapor. From these experiments individual components were identified for further in vivo and in vitro toxicological testing. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:11 / 20
页数:10
相关论文
共 50 条
  • [31] A Gas Chromatography Mass Spectrometry-Based Method for the Quantification of Short Chain Fatty Acids
    Rohde, Julia K.
    Fuh, Marceline M.
    Evangelakos, Ioannis
    Pauly, Mira J.
    Schaltenberg, Nicola
    Siracusa, Francesco
    Gagliani, Nicola
    Toedter, Klaus
    Heeren, Joerg
    Worthmann, Anna
    METABOLITES, 2022, 12 (02)
  • [32] Development and validation of a gas chromatography/mass spectrometry method for simultaneous quantification of benzylpiperazine and its metabolites: Application to a pilot toxicokinetic study in mice
    Monteiro, M.
    Carvalho, M.
    Bastos, M. L.
    Guedes de Pinho, P.
    TOXICOLOGY LETTERS, 2013, 221 : S185 - S186
  • [33] Development and validation of a liquid chromatography-tandem mass spectrometry method for the quantification of opiorphin in human saliva
    Brkljacic, Lidija
    Sabalic, Maja
    Salaric, Ivan
    Jeric, Ivanka
    Alajbeg, Ivan
    Nemet, Ina
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (32): : 3920 - 3926
  • [34] Development and validation of a liquid chromatography/tandem mass spectrometry method for the quantification of flucloxacillin and cloxacillin in microdialysis samples
    Larmene-Beld, Karin H. M.
    Vries-Koenjer, Marie-Therese L. M.
    ter Horst, Peter G. J.
    Hospes, Wobbe
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (08) : 1096 - 1101
  • [35] Coupling of gas chromatography with Jet-REMPI spectroscopy and mass spectrometry
    Zimmermann, R
    Heger, HJ
    Rohwer, ER
    Schlag, EW
    Kettrup, A
    Boesl, U
    RESONANCE IONIZATION SPECTROSCOPY 1996 - EIGHTH INTERNATIONAL SYMPOSIUM, 1997, (388): : 119 - 122
  • [36] Development and validation of a liquid chromatography-tandem mass spectrometry method for quantification of decitabine in rat plasma
    Xu, Haiyan
    Iv, Shaoqiong
    Qiao, Mingxi
    Fu, Yao
    Jiang, Xue
    Jin, Yi
    Li, Chibing
    Yuan, Bo
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 899 : 81 - 85
  • [37] The Analysis of Aerosolized Methamphetamine From E-cigarettes Using High Resolution Mass Spectrometry and Gas Chromatography Mass Spectrometry
    Krakowiak, Rose I.
    Poklis, Justin L.
    Peace, Michelle R.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2019, 43 (08) : 592 - 599
  • [38] Optimization of focused ultrasonic extraction of propellant components determined by gas chromatography/mass spectrometry
    Frys, Ondrej
    Cesla, Petr
    Bajerova, Petra
    Adam, Martin
    Ventura, Karel
    TALANTA, 2012, 99 : 316 - 322
  • [39] Mass Fragmentation Studies of α-Tomatine and Validation of a Liquid Chromatography LTQ Orbitrap Mass Spectrometry Method for Its Quantification in Tomatoes
    Giovanni Caprioli
    Michael G. Cahill
    Kevin J. James
    Food Analytical Methods, 2014, 7 : 1565 - 1571
  • [40] Mass Fragmentation Studies of α-Tomatine and Validation of a Liquid Chromatography LTQ Orbitrap Mass Spectrometry Method for Its Quantification in Tomatoes
    Caprioli, Giovanni
    Cahill, Michael G.
    James, Kevin J.
    FOOD ANALYTICAL METHODS, 2014, 7 (08) : 1565 - 1571