Validation of a gas chromatography/mass spectrometry method for the quantification of aerosolized Jet Propellant 8

被引:19
|
作者
Dietzel, KD [1 ]
Campbell, JL [1 ]
Bartlett, MG [1 ]
Witten, ML [1 ]
Fisher, JW [1 ]
机构
[1] Univ Georgia, Dept Environm Hlth Sci, Interdisciplinary Toxicol Program, Athens, GA 30602 USA
关键词
JP-8; GC/MS; hydrocarbon analysis; jet fuel; inhalation studies;
D O I
10.1016/j.chroma.2005.07.049
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Jet Propellant 8 (JP-8) jet fuel is a kerosene-based fuel containing hundreds of hydrocarbons used by the military in NATO countries. Previous rodent inhalation studies carried out with aerosolized JP-8 never evaluated the exposure chamber atmosphere. For this reason, our laboratory developed an analytical method, with an accuracy of better than 80% and precision of better than 20%, for JP-8 aerosol and vapor samples using gas chromatography/mass spectrometry (GC/MS). A method was developed for quantification of selected individual components of JP-8 and for the total amount of JP-8 in aerosolized fuel. A 34 component surrogate hydrocarbon mixture (SHM) was developed and used for simultaneous analysis of the individual components. Three separate runs containing a standard curve and five replicates each at the selected concentrations were analyzed for both the SHM and neat JP-8. The resulting interday accuracy (100 - percent relative error) and precision (relative standard deviation) values for the SHM were 86.5% or better and 8.0% or better, respectively. The intraday accuracy and precision values ranged from 99.29% to 84.50% and 0.97% to 12.4%, respectively. For the total amount of JP-8 in aerosol and vapor, the interday accuracy was 83.7% or better and interday precision was 7.0% or better. The intraday accuracy and precision values ranged from 94.8% to 80.4% and 2.4% to 10.5%, respectively. We then used this method to analyze samples collected from an inhalation chamber. From the data obtained, we are able to account for approximately 40-44% of the mass of the aerosol portion and 68-70% of the mass of the vapor portion. The aerosol represented 6-10% of the total mass of the aerosolized JP-8 fuel with the remaining portion being the vapor. From these experiments individual components were identified for further in vivo and in vitro toxicological testing. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:11 / 20
页数:10
相关论文
共 50 条
  • [21] Quantification of suvorexant in urine using gas chromatography/mass spectrometry
    Carson, Mariah
    Kerrigan, Sarah
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1040 : 289 - 294
  • [22] Development and validation of an assay method of the paraphenylene diamine by gas chromatography-mass spectrometry
    Bousliman, Yassir
    Eljaoudi, Rachid
    Elcadi, Mina Ait
    Basset, Thiery
    Gay-Montchamp, Jean-Pierre
    Zeggwagh, Amine Ali
    Bouklouze, Abdelaziz
    Cherrah, Yahia
    Ollagnier, Michel
    ANNALES DE BIOLOGIE CLINIQUE, 2012, 70 (06) : 678 - 682
  • [23] Validation of a Gas Chromatography/Mass Spectrometry Method for Quantitative Determination of Zolpidem in Whole Blood
    Krylova, E. A.
    Kataev, S. S.
    Khomov, Yu. A.
    Dvorskaya, O. N.
    PHARMACEUTICAL CHEMISTRY JOURNAL, 2015, 49 (08) : 564 - 569
  • [24] Development and validation of a gas chromatography/mass spectrometry method for the assessment of genomic DNA methylation
    Rossella, Federica
    Polledri, Elisa
    Bollati, Valentina
    Baccarelli, Andrea
    Fustinoni, Silvia
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (17) : 2637 - 2646
  • [25] Microalgae amino acids: Method validation using gas chromatography coupled to mass spectrometry
    Furlan, Junior Mendes
    Cunha, Joao Pedro da Silva
    Ribas, Veronica Bueno
    da Silva, Kassandra Fontoura
    dos Santos, Betania Nascimento
    Centenaro, Graciela Salete
    Wagner, Roger
    Vendruscolo, Raquel Guidetti
    JOURNAL OF APPLIED PHYCOLOGY, 2024, 36 (03) : 1153 - 1167
  • [26] Validation of a Gas Chromatography/Mass Spectrometry Method for Quantitative Determination of Zolpidem in Whole Blood
    E. A. Krylova
    S. S. Kataev
    Yu. A. Khomov
    O. N. Dvorskaya
    Pharmaceutical Chemistry Journal, 2015, 49 : 564 - 569
  • [27] Internal Validation of the Method for Determination of Acrylamide in Bread by Gas Chromatography Tandem Mass Spectrometry
    Negoita, Mioara
    Adascalului, Alina
    Iorga, Enuta
    Catana, Luminita
    Catana, Monica
    Belc, Nastasia
    REVISTA DE CHIMIE, 2015, 66 (04): : 464 - 471
  • [28] Validation of the gas chromatography-mass spectrometry method for the determination of chloramphenicol residues in milk
    Sniegocki, Tomasz
    Posyniak, Andrzej
    Zmudzki, Jan
    BULLETIN OF THE VETERINARY INSTITUTE IN PULAWY, 2006, 50 (03) : 353 - 357
  • [29] Efficient and sensitive method for the quantification of saturated monoacylglycerols in biodiesel by gas chromatography-mass spectrometry
    Hirschegger, Lena
    Schober, Sigurd
    Mittelbach, Martin
    EUROPEAN JOURNAL OF LIPID SCIENCE AND TECHNOLOGY, 2014, 116 (01) : 89 - 96
  • [30] A novel method for quantification of sulfolane (a metabolite of busulfan) in plasma by gas chromatography–tandem mass spectrometry
    François Versace
    Chakradhara Rao S. Uppugunduri
    Maja Krajinovic
    Yves Théorêt
    Fabienne Gumy-Pause
    Patrice Mangin
    Christian Staub
    Marc Ansari
    Analytical and Bioanalytical Chemistry, 2012, 404 : 1831 - 1838