Experimental investigation of steel fiber RC hollow columns under eccentric loading

被引:6
|
作者
Azzawi, Raad [1 ]
Abolmaail, Ali [2 ]
机构
[1] Univ Texas Arlington, Dept Civil Engn, Arlington, TX 76019 USA
[2] Univ Texas Arlington, Dept Civil Engn, Dept Chair, Arlington, TX 76019 USA
关键词
Concrete Breakout; Columns; Steel Fibers; Experimental study; Composite materials; SELF-COMPACTING CONCRETE; MECHANICAL-PROPERTIES; PERFORMANCE; GLASS; WORKABILITY; STRENGTH;
D O I
10.1016/j.istruc.2019.12.023
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
an investigation was conducted to identify the behavior of steel fiber reinforced concrete columns with an opening under eccentricity loading, focusing on square hollow columns section having different square hole sizes and various steel fiber dosages were cast and tested. The holes pass longitudinally at the center of the cross-section of the columns. The research includes a test of nine columns of dimensions (200 x 200 x 1600 mm). Test parameters were the steel fiber contents (0.5%, 1.0% and 1.5% volume fraction) and opening ratio (10% and 20% hollow ratio) with load eccentricity (eccentricity/column depth ratio is 0.75). The compressive strength cylinder tests are conducted for various steel fiber dosages in terms of volume fraction. First cracking load, lateral displacement and ultimate load for each column are calculated and compared with similar columns made of ordinary reinforced concrete with and without a hole. The experimental results show that for concrete columns with hollow ratios 10% and 20% (C2-I, C-II) and without steel fibers, the first cracking load reduction was 28.88% and 49.70% respectively compared with the solid column (C1-I, C1-II). The addition of steel fibers significantly improves the mechanical response of the tested specimens especially the cracking load. The cracking load for specimen C5-I (10% opening ratio with 1.5% steel fibers volume fraction) increased 2.346 times the cracking load for specimen C2-I (10% opening ratio without steel fibers) and for a specimen with a 20% opening ratio and 1.5% steel fibers volume fraction (C5-II), the cracking load increased 2.181 times the same specimen without adding steel fibers. The ultimate load-carrying capacity for specimen C5-I (10% opening ratio with 1.5% steel fibers volume fraction) increased 1.094 times the cracking load for specimen C2-I (10% opening ratio without steel fibers) and for a specimen with a 20% opening ratio and 1.5% steel fibers volume fraction (C5-II), the ultimate load-carrying capacity increased 1.23 times the same specimen without adding steel fibers. The test results indicate the addition of steel fiber enhanced the strength capacity, ductility and allowing these columns to absorb more energy compared with a similar column with ordinary reinforced concrete.
引用
收藏
页码:456 / 463
页数:8
相关论文
共 50 条
  • [41] Behavior of Reactive Powder Concrete Hollow Core Columns Strengthened with Carbon Fiber Reinforced Polymer Under Eccentric Loading
    Falah, M. W.
    Ali, Y. A.
    Al-Khafaji, Z.
    Al-Mulali, M. Z.
    Al-Husseinawi, F. N.
    ELECTRONIC JOURNAL OF STRUCTURAL ENGINEERING, 2022, 22 (03): : 29 - 38
  • [42] Experimental studies on steel fiber reinforced short ternary columns under axial loading
    Suda, V. B. Reddy
    Rao, P. Srinivasa
    MATERIALS TODAY-PROCEEDINGS, 2021, 38 : 2975 - 2980
  • [43] Experimental investigation of FRP wrapped RC circular and square hollow columns
    Hadi, M. N. S.
    Kusumawardaningsih, Y.
    CHALLENGES, OPPORTUNITIES AND SOLUTIONS IN STRUCTURAL ENGINEERING AND CONSTRUCTION, 2010, : 235 - 240
  • [44] Buckling behavior of stainless steel square hollow columns under eccentric loadings
    Jang, Ho-Ju
    Seo, Seong-Yeon
    Yang, Young-Sung
    STRUCTURAL ENGINEERING AND MECHANICS, 2006, 23 (05) : 563 - 577
  • [46] Structural behavior of UHPC filled steel tubular columns under eccentric loading
    Zhang, Rui
    Chen, Shiming
    Gu, Ping
    Huang, Yang
    THIN-WALLED STRUCTURES, 2020, 156
  • [47] Behavior of partially precast steel reinforced concrete columns under eccentric loading
    Yang, Yong
    Chen, Yang
    Zhang, Wensong
    Feng, Shiqiang
    ENGINEERING STRUCTURES, 2019, 197
  • [48] Experimental investigation of stainless steel circular hollow section columns
    Young, B
    Hartono, W
    THIN-WALLED STRUCTURES: ADVANCES AND DEVELOPMENTS, 2001, : 257 - 265
  • [49] Experimental investigation on RC and retrofitted RC column under cyclic loading
    Murugesan, A.
    Thirugnanam, G.S.
    International Journal of Earth Sciences and Engineering, 2014, 7 (03): : 1164 - 1170
  • [50] EXPERIMENTAL STUDY ON COMPRESSION BEHAVIOR OF CONCRETE COLUMNS WITH HIGH STRENGTH STEEL BARS UNDER SMALL ECCENTRIC LOADING
    Ma L.-C.
    Shi Q.-X.
    Wang P.
    Wang Q.-W.
    Gongcheng Lixue/Engineering Mechanics, 2024, (03): : 82 - 90