Experimental investigation of steel fiber RC hollow columns under eccentric loading

被引:6
|
作者
Azzawi, Raad [1 ]
Abolmaail, Ali [2 ]
机构
[1] Univ Texas Arlington, Dept Civil Engn, Arlington, TX 76019 USA
[2] Univ Texas Arlington, Dept Civil Engn, Dept Chair, Arlington, TX 76019 USA
关键词
Concrete Breakout; Columns; Steel Fibers; Experimental study; Composite materials; SELF-COMPACTING CONCRETE; MECHANICAL-PROPERTIES; PERFORMANCE; GLASS; WORKABILITY; STRENGTH;
D O I
10.1016/j.istruc.2019.12.023
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
an investigation was conducted to identify the behavior of steel fiber reinforced concrete columns with an opening under eccentricity loading, focusing on square hollow columns section having different square hole sizes and various steel fiber dosages were cast and tested. The holes pass longitudinally at the center of the cross-section of the columns. The research includes a test of nine columns of dimensions (200 x 200 x 1600 mm). Test parameters were the steel fiber contents (0.5%, 1.0% and 1.5% volume fraction) and opening ratio (10% and 20% hollow ratio) with load eccentricity (eccentricity/column depth ratio is 0.75). The compressive strength cylinder tests are conducted for various steel fiber dosages in terms of volume fraction. First cracking load, lateral displacement and ultimate load for each column are calculated and compared with similar columns made of ordinary reinforced concrete with and without a hole. The experimental results show that for concrete columns with hollow ratios 10% and 20% (C2-I, C-II) and without steel fibers, the first cracking load reduction was 28.88% and 49.70% respectively compared with the solid column (C1-I, C1-II). The addition of steel fibers significantly improves the mechanical response of the tested specimens especially the cracking load. The cracking load for specimen C5-I (10% opening ratio with 1.5% steel fibers volume fraction) increased 2.346 times the cracking load for specimen C2-I (10% opening ratio without steel fibers) and for a specimen with a 20% opening ratio and 1.5% steel fibers volume fraction (C5-II), the cracking load increased 2.181 times the same specimen without adding steel fibers. The ultimate load-carrying capacity for specimen C5-I (10% opening ratio with 1.5% steel fibers volume fraction) increased 1.094 times the cracking load for specimen C2-I (10% opening ratio without steel fibers) and for a specimen with a 20% opening ratio and 1.5% steel fibers volume fraction (C5-II), the ultimate load-carrying capacity increased 1.23 times the same specimen without adding steel fibers. The test results indicate the addition of steel fiber enhanced the strength capacity, ductility and allowing these columns to absorb more energy compared with a similar column with ordinary reinforced concrete.
引用
收藏
页码:456 / 463
页数:8
相关论文
共 50 条
  • [31] Experimental Study of Hollow RC Beams Strengthened by Steel Fiber under Pure Torsion
    Abdullah, Mazin Diwan
    Malik, Hawraa S.
    JOURNAL OF ENGINEERING, 2022, 2022
  • [32] Analysis of RC columns strengthened with ultra-high performance fiber reinforced concrete jackets under eccentric loading
    Sakr, Mohammed A.
    El Korany, Tamer M.
    Osama, Bothaina
    ENGINEERING STRUCTURES, 2020, 220
  • [33] Experimental study of strengthening of RC columns with steel fiber concrete
    Mhuder W.J.
    Chassib S.M.
    Materials Science Forum, 2020, 1002 : 551 - 564
  • [34] Behaviour of RC columns strengthened with Ultra-High Performance Fiber Reinforced concrete (UHPFRC) under eccentric loading
    Elsayed, Mahmoud
    Tayeh, Bassam A.
    Abou Elmaaty, Mohamed
    Aldahshoory, Yomna
    JOURNAL OF BUILDING ENGINEERING, 2022, 47
  • [35] Experimental Study on Seismic Performance of RC Composite Core Walls with Steel Tube-Reinforced Concrete Columns and Concealed Steel Trusses under Eccentric Horizontal Loading
    Dong, Hongying
    Cao, Wanlin
    Zhang, Jianwei
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 2267 - 2273
  • [36] CONFINED COLUMNS UNDER ECCENTRIC LOADING
    SAATCIOGLU, M
    SALAMAT, AH
    RAZVI, SR
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1995, 121 (11): : 1547 - 1556
  • [37] SIZE EFFECT TESTS OF HIGH-STRENGTH RC COLUMNS UNDER ECCENTRIC LOADING
    Jin, Liu
    Ding, Zixing
    Li, Dong
    Du, Xiuli
    FUNDAMENTAL RESEARCH IN STRUCTURAL ENGINEERING: RETROSPECTIVE AND PROSPECTIVE, VOLS 1 AND 2, 2016, : 1804 - 1809
  • [38] Size effect tests of high-strength RC columns under eccentric loading
    Xu, Chengshun
    Jin, Liu
    Ding, Zixing
    Li, Dong
    Du, Xiuli
    ENGINEERING STRUCTURES, 2016, 126 : 78 - 91
  • [39] Axial and Flexural Performance of Square RC Columns Wrapped with CFRP under Eccentric Loading
    Hadi, Muhammad N. S.
    Widiarsa, Ida Bagus Rai
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2012, 16 (06) : 640 - 649
  • [40] Performance of corroded rectangular RC columns strengthened with CFRP composite under eccentric loading
    Chotickai, Piya
    Tongya, Pichai
    Jantharaksa, Satja
    CONSTRUCTION AND BUILDING MATERIALS, 2021, 268