Experimental investigation of steel fiber RC hollow columns under eccentric loading

被引:6
|
作者
Azzawi, Raad [1 ]
Abolmaail, Ali [2 ]
机构
[1] Univ Texas Arlington, Dept Civil Engn, Arlington, TX 76019 USA
[2] Univ Texas Arlington, Dept Civil Engn, Dept Chair, Arlington, TX 76019 USA
关键词
Concrete Breakout; Columns; Steel Fibers; Experimental study; Composite materials; SELF-COMPACTING CONCRETE; MECHANICAL-PROPERTIES; PERFORMANCE; GLASS; WORKABILITY; STRENGTH;
D O I
10.1016/j.istruc.2019.12.023
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
an investigation was conducted to identify the behavior of steel fiber reinforced concrete columns with an opening under eccentricity loading, focusing on square hollow columns section having different square hole sizes and various steel fiber dosages were cast and tested. The holes pass longitudinally at the center of the cross-section of the columns. The research includes a test of nine columns of dimensions (200 x 200 x 1600 mm). Test parameters were the steel fiber contents (0.5%, 1.0% and 1.5% volume fraction) and opening ratio (10% and 20% hollow ratio) with load eccentricity (eccentricity/column depth ratio is 0.75). The compressive strength cylinder tests are conducted for various steel fiber dosages in terms of volume fraction. First cracking load, lateral displacement and ultimate load for each column are calculated and compared with similar columns made of ordinary reinforced concrete with and without a hole. The experimental results show that for concrete columns with hollow ratios 10% and 20% (C2-I, C-II) and without steel fibers, the first cracking load reduction was 28.88% and 49.70% respectively compared with the solid column (C1-I, C1-II). The addition of steel fibers significantly improves the mechanical response of the tested specimens especially the cracking load. The cracking load for specimen C5-I (10% opening ratio with 1.5% steel fibers volume fraction) increased 2.346 times the cracking load for specimen C2-I (10% opening ratio without steel fibers) and for a specimen with a 20% opening ratio and 1.5% steel fibers volume fraction (C5-II), the cracking load increased 2.181 times the same specimen without adding steel fibers. The ultimate load-carrying capacity for specimen C5-I (10% opening ratio with 1.5% steel fibers volume fraction) increased 1.094 times the cracking load for specimen C2-I (10% opening ratio without steel fibers) and for a specimen with a 20% opening ratio and 1.5% steel fibers volume fraction (C5-II), the ultimate load-carrying capacity increased 1.23 times the same specimen without adding steel fibers. The test results indicate the addition of steel fiber enhanced the strength capacity, ductility and allowing these columns to absorb more energy compared with a similar column with ordinary reinforced concrete.
引用
收藏
页码:456 / 463
页数:8
相关论文
共 50 条
  • [1] Experimental Investigation of Preloaded RC Columns Strengthened with Precambered Steel Plates Under Eccentric Compression Loading
    Wang, L.
    Su, R. K. L.
    ADVANCES IN STRUCTURAL ENGINEERING, 2012, 15 (08) : 1253 - 1264
  • [2] Experimental study of RC columns strengthened with steel fiber cement mortar with mesh reinforcement under eccentric loading
    College of Civil Engineering, Hunan Univ., Changsha, Hunan 410082, China
    Hunan Daxue Xuebao, 3 (15-20):
  • [3] Experimental investigation on axial behaviour of RC columns subjected to steel corrosion under loading
    Civil Engineering Department, V.L.B. Janakiammal College of Engineering and Technology, Coimbatore
    不详
    Indian Concr J, 2006, 11 (38-45):
  • [4] Experimental Investigation on the Behavior of Steel Angle and Strip Jacketed RC Column Under Eccentric Loading
    Sen D.
    Begum M.
    J. Inst. Eng. Ser. A, 1 (77-89): : 77 - 89
  • [5] Numerical and Experimental Investigation on Eccentric Loading Behavior of RC Columns Strengthened with SCC Filled Square Steel Tubes
    Lu, Yi-Yan
    Liang, Hong-Jun
    Li, Shan
    Li, Na
    ADVANCES IN STRUCTURAL ENGINEERING, 2015, 18 (02) : 295 - 309
  • [6] Experimental and numerical investigation of pultruded GFRP circular hollow tubular columns under concentric and eccentric loading
    Higgoda, Thumitha Mandula
    Elchalakani, Mohamed
    Kimiaei, Mehrdad
    Wittek, Adam
    Yang, Bo
    COMPOSITE STRUCTURES, 2023, 304
  • [7] Investigation of mechanical behavior of RC columns strengthened with glass fiber-reinforced polymer under eccentric loading
    Lab. of Coastal and Offshore Eng., Dalian Univ. of Technol., Dalian 116023, China
    1600, 87-93 (October 2004):
  • [8] Investigation of GFRP strengthened RC non-slender columns under eccentric loading
    Vesmawala, Gaurang R.
    Kodag, Pradeep B.
    GRADEVINAR, 2017, 69 (09): : 831 - 840
  • [9] Experimental Study of Rectangular RC Columns Strengthened with CFRP Composites under Eccentric Loading
    Sadeghian, Pedram
    Rahai, Ali R.
    Ehsani, Mohammad R.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (04) : 443 - 450
  • [10] Experimental investigation on slender steel reinforced concrete columns with monosymmetric cross-shaped steel under eccentric loading
    Zhou T.-H.
    Yu J.-P.
    Zhang Y.
    Li Y.-P.
    Gongcheng Lixue/Engineering Mechanics, 2021, 38 (04): : 111 - 122