Anodic stripping voltammetric determination of titanium(IV) using a carbon paste electrode modified with cetyltrimethylammonium bromide

被引:47
|
作者
Stadlober, M [1 ]
Kalcher, K [1 ]
Raber, G [1 ]
Neuhold, C [1 ]
机构
[1] KARL FRANZENS UNIV GRAZ,INST ANALYT CHEM,A-8010 GRAZ,AUSTRIA
关键词
anodic stripping voltammetry; carbon paste electrodes; cetyltrimethylammonium bromide; titanium;
D O I
10.1016/0039-9140(96)01977-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method is described for the voltammetric determination of titanium(IV) using a carbon paste electrode modified in situ with cetyltrimethylammonium bromide. The cationic micellar surfactant adsorbs onto the electrode particularly at negative potentials, simultaneously preconcentrating titanium(IV) as the oxalate complex with reduction to titanium(III). Anodic stripping voltammetry exploiting reoxidation can be used for the determination of trace levels of titanium(IV). Linearity between current and concentration exists between 5 and 160 mu g l(-1) Ti(IV) (preconcentration time 2 min). The limit of detection (calculated as 3 sigma) is 0.1 mu g l(-1), with a preconcentration time of 10 min.
引用
收藏
页码:1915 / 1924
页数:10
相关论文
共 50 条