Intercomparison of the realization of the ITS-90 at the freezing points of al and ag among european NMIs

被引:8
|
作者
Heyer, D.
Noatsch, U.
Tegeler, E.
Anagnostou, M.
Turzo-Andras, E.
Antonsen, I.
Augevicius, V.
Bojkovski, J.
Bronnum, A.
Chimenti, V.
Duris, S.
Filipe, E.
Gaita, S.
Gray, J.
Head, D.
Grudniewicz, E.
Ivarsson, J.
Kalemci, M.
Kerkhof, O.
Lobo, I.
Nemeth, S.
Pokhodun, A.
Ranostaj, J.
Renaot, E.
Rosenkranz, P.
Smid, M.
Steur, P.
Steiner, A.
Valin, M.
Veliki, T.
Weckstrom, T.
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
[2] Hellen Inst Metrol, Thessaloniki, Greece
[3] Natl Off Measure, Budapest, Hungary
[4] Natl Stand Lab, Kjeller, Norway
[5] Temperature Stand Lab, Vilnius, Lithuania
[6] Lab Metrol & Qual, MIRS, FE LMK, Ljubljana, Slovenia
[7] Teknol Inst, Aarhus, Denmark
[8] Ctr Espanol Metrol, Madrid, Spain
[9] Slovak Inst Metrol, Bratislava, Slovakia
[10] Inst Portugues Qualidade, Caparica, Portugal
[11] Inst Natl Metrol, Bucharest, Romania
[12] Natl Phys Lab, Teddington, Middx, England
关键词
Al freezing point; Ag freezing point; CCT; EUROMET; fixed points; high-temperature standard platinum resistance thermometers; key comparison; Matthiessen's rule;
D O I
10.1007/s10765-007-0283-y
中图分类号
O414.1 [热力学];
学科分类号
摘要
The EUROMET.T-K4 comparison is the regional extension of CCT-K4, an intercomparison of the realizations of the freezing points of Al (660.323 degrees C) and Ag (961.78 degrees C). The intercomparison was organized in four loops. Long-stem standard platinum resistance thermometers (SPRTs) were used as traveling standards: 25 Omega thermometers to be used only at the Al freezing point and two high-temperature standard platinum resistance thermometers (HTSPRTs) to be used only at the Ag freezing point in each loop. Parallel to the measurements with thermometers, the pilots and sub-pilots organized an internal intercomparison using an Ag fixed-point cell. Most HTSPRTs showed a strong drift which is mainly due to mechanical stress and poisoning of the sensor by impurities. This drift can be partially compensated by a correction based on Matthiessen's rule. An evaluation of the data taking into account both HTSPRTs in each loop, the linkage of the sub-pilots by measurements at the Ag freezing point, and a possible compensation according to Matthiessens's rule, allows calculation of the results of the participants' measurements at the Ag freezing point. The results of the participating laboratories are summarized, and proposals for key comparison reference values and linking of the results to CCT-K3 and CCT-K4 are presented.
引用
收藏
页码:1964 / 1975
页数:12
相关论文
共 50 条
  • [21] Traceability, and the qualification of ITS-90 fixed points
    Tavener, J
    PTB-MITTEILUNGEN, 1997, 107 (06): : 421 - 427
  • [22] Influence of the Opening of a Blackbody Cavity Measured at the Ag and Cu ITS-90 Fixed Points
    Bourson, F.
    Sadli, M.
    Rougie, B.
    Briaudeau, S.
    Kozlova, O.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2014, 35 (3-4) : 516 - 525
  • [23] Realization of ITS-90 Above the Silver Point at the NIM
    Yuan, Z.
    Lu, X.
    Wang, J.
    Bai, C.
    Dong, W.
    Hao, X.
    Wang, T.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2011, 32 (7-8) : 1611 - 1621
  • [24] ITS-90: the instability of the Al point
    Ancsin, J
    METROLOGIA, 2003, 40 (05) : 232 - 234
  • [25] Realization of ITS-90 Above the Silver Point at the NIM
    Z. Yuan
    X. Lu
    J. Wang
    C. Bai
    W. Dong
    X. Hao
    T. Wang
    International Journal of Thermophysics, 2011, 32 : 1611 - 1621
  • [26] Uncertainty budgets for realization of ITS-90 by radiation thermometry
    Fischer, J
    Battuello, M
    Sadli, M
    Ballico, M
    Park, SN
    Saunders, P
    Yuan, ZD
    Johnson, BC
    van der Ham, E
    Sakuma, F
    Machin, G
    Fox, N
    Li, W
    Ugur, S
    Matveyev, M
    TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 7, PTS 1 AND 2, 2003, 684 : 631 - 638
  • [27] Final report on EUROMET.T-K4 (EUROMET Project 820): Comparison of the realizations of the ITS-90 at the freezing points of Al (660.323 °C) and Ag (961.78 °C)
    Heyer, D.
    Noatsch, U.
    Tegeler, E.
    Anagnostou, M.
    Turzo-Andras, E.
    Antonsen, I.
    Augevicius, V.
    Bojkovski, J.
    Bronnum, A.
    Chimenti, V.
    Duris, S.
    Filipe, E.
    Gaita, S.
    Gray, J.
    Head, D.
    Grudniewicz, E.
    Ivarsson, J.
    Kalemci, M.
    Kerkhof, O.
    Lobo, I.
    Nemeth, S.
    Pokhodun, A.
    Ranostaj, J.
    Renaot, E.
    Rosenkranz, P.
    Smid, M.
    Steur, P.
    Steiner, A.
    Valin, M.
    Veliki, T.
    Weckstrom, T.
    METROLOGIA, 2008, 45
  • [28] Disseminating the ITS-90 Traceability in Industry—An Intercomparison of Temperature Block Calibrators
    J. Nielsen
    J. Domino
    M. B. Nielsen
    International Journal of Thermophysics, 2011, 32 : 1485 - 1495
  • [29] Uncertainties in the Realization of the SPRT Sub-ranges of the ITS-90
    D. R. White
    M. Ballico
    D. del Campo
    S. Duris
    E. Filipe
    A. Ivanova
    A. Kartal Dogan
    E. Mendez-Lango
    C. W. Meyer
    F. Pavese
    A. Peruzzi
    E. Renaot
    S. Rudtsch
    K. Yamazawa
    International Journal of Thermophysics, 2007, 28 : 1868 - 1881
  • [30] REALIZATION OF THE ITS-90 AT IMGC IN THE RANGE OF LONG STEM PRTS
    MARCARINO, P
    DEMATTEIS, R
    MEASUREMENT TECHNIQUES USSR, 1993, 36 (12): : 1406 - 1414