Intercomparison of the realization of the ITS-90 at the freezing points of al and ag among european NMIs

被引:8
|
作者
Heyer, D.
Noatsch, U.
Tegeler, E.
Anagnostou, M.
Turzo-Andras, E.
Antonsen, I.
Augevicius, V.
Bojkovski, J.
Bronnum, A.
Chimenti, V.
Duris, S.
Filipe, E.
Gaita, S.
Gray, J.
Head, D.
Grudniewicz, E.
Ivarsson, J.
Kalemci, M.
Kerkhof, O.
Lobo, I.
Nemeth, S.
Pokhodun, A.
Ranostaj, J.
Renaot, E.
Rosenkranz, P.
Smid, M.
Steur, P.
Steiner, A.
Valin, M.
Veliki, T.
Weckstrom, T.
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
[2] Hellen Inst Metrol, Thessaloniki, Greece
[3] Natl Off Measure, Budapest, Hungary
[4] Natl Stand Lab, Kjeller, Norway
[5] Temperature Stand Lab, Vilnius, Lithuania
[6] Lab Metrol & Qual, MIRS, FE LMK, Ljubljana, Slovenia
[7] Teknol Inst, Aarhus, Denmark
[8] Ctr Espanol Metrol, Madrid, Spain
[9] Slovak Inst Metrol, Bratislava, Slovakia
[10] Inst Portugues Qualidade, Caparica, Portugal
[11] Inst Natl Metrol, Bucharest, Romania
[12] Natl Phys Lab, Teddington, Middx, England
关键词
Al freezing point; Ag freezing point; CCT; EUROMET; fixed points; high-temperature standard platinum resistance thermometers; key comparison; Matthiessen's rule;
D O I
10.1007/s10765-007-0283-y
中图分类号
O414.1 [热力学];
学科分类号
摘要
The EUROMET.T-K4 comparison is the regional extension of CCT-K4, an intercomparison of the realizations of the freezing points of Al (660.323 degrees C) and Ag (961.78 degrees C). The intercomparison was organized in four loops. Long-stem standard platinum resistance thermometers (SPRTs) were used as traveling standards: 25 Omega thermometers to be used only at the Al freezing point and two high-temperature standard platinum resistance thermometers (HTSPRTs) to be used only at the Ag freezing point in each loop. Parallel to the measurements with thermometers, the pilots and sub-pilots organized an internal intercomparison using an Ag fixed-point cell. Most HTSPRTs showed a strong drift which is mainly due to mechanical stress and poisoning of the sensor by impurities. This drift can be partially compensated by a correction based on Matthiessen's rule. An evaluation of the data taking into account both HTSPRTs in each loop, the linkage of the sub-pilots by measurements at the Ag freezing point, and a possible compensation according to Matthiessens's rule, allows calculation of the results of the participants' measurements at the Ag freezing point. The results of the participating laboratories are summarized, and proposals for key comparison reference values and linking of the results to CCT-K3 and CCT-K4 are presented.
引用
收藏
页码:1964 / 1975
页数:12
相关论文
共 50 条
  • [11] A criterion for uniformity of a temperature field in realization of the ITS-90 fixed points
    Ilin, AU
    TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 7, PTS 1 AND 2, 2003, 684 : 297 - 301
  • [12] Realization of Low-Temperature Fixed Points of the ITS-90 at NMIJ/AIST
    T. Nakano
    O. Tamura
    H. Sakurai
    International Journal of Thermophysics, 2007, 28 : 1893 - 1903
  • [13] Realization of low-temperature fixed points of the ITS-90 at NMIJ/AIST
    Nakano, T.
    Tamura, O.
    Sakurai, H.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2007, 28 (06) : 1893 - 1903
  • [14] Realization of two temperature reference points between argon and mercury fixed points on ITS-90
    El-Shamma, H
    TEMPMEKO 2001: 8TH INTERNATIONAL SYMPOSIUM ON TEMPERATURE AND THERMAL MEASUREMENT IN INDUSTRY AND SCIENCE, VOL 1 & 2, PROCEEDINGS, 2002, : 435 - 440
  • [15] Realization at IMGC of the ITS-90 fixed points from the argon triple point upwards
    Marcarino, P
    Steur, PPM
    Dematteis, R
    TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 7, PTS 1 AND 2, 2003, 684 : 65 - 70
  • [16] The Comparison of MTDATA with the Melting/Freezing Point Curves of ITS-90 Metal Fixed Points
    D. I. Head
    H. Davies
    J. Gray
    P. Quested
    International Journal of Thermophysics, 2008, 29 : 1796 - 1807
  • [17] The comparison of MTDATA with the melting/freezing point curves of ITS-90 metal fixed points
    Head, D. I.
    Davies, H.
    Gray, J.
    Quested, P.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2008, 29 (05) : 1796 - 1807
  • [18] Intercomparison of the realization of the ITS-90 in the temperature range -40°C to 420°C between CENAM and PTB
    Noatsch, U
    Tegeler, E
    Méndez-Lango, E
    TEMPERATURE: ITS MEASUREMENT AND CONTROL IN SCIENCE AND INDUSTRY, VOL 7, PTS 1 AND 2, 2003, 684 : 855 - 859
  • [19] Oxides in metal fixed points of the ITS-90
    Fahr, Martin
    Rudtsch, Steffen
    METROLOGIA, 2009, 46 (05) : 423 - 438
  • [20] Influence of the Opening of a Blackbody Cavity Measured at the Ag and Cu ITS-90 Fixed Points
    F. Bourson
    M. Sadli
    B. Rougié
    S. Briaudeau
    O. Kozlova
    International Journal of Thermophysics, 2014, 35 : 516 - 525