Intercomparison of the realization of the ITS-90 at the freezing points of al and ag among european NMIs

被引:8
|
作者
Heyer, D.
Noatsch, U.
Tegeler, E.
Anagnostou, M.
Turzo-Andras, E.
Antonsen, I.
Augevicius, V.
Bojkovski, J.
Bronnum, A.
Chimenti, V.
Duris, S.
Filipe, E.
Gaita, S.
Gray, J.
Head, D.
Grudniewicz, E.
Ivarsson, J.
Kalemci, M.
Kerkhof, O.
Lobo, I.
Nemeth, S.
Pokhodun, A.
Ranostaj, J.
Renaot, E.
Rosenkranz, P.
Smid, M.
Steur, P.
Steiner, A.
Valin, M.
Veliki, T.
Weckstrom, T.
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
[2] Hellen Inst Metrol, Thessaloniki, Greece
[3] Natl Off Measure, Budapest, Hungary
[4] Natl Stand Lab, Kjeller, Norway
[5] Temperature Stand Lab, Vilnius, Lithuania
[6] Lab Metrol & Qual, MIRS, FE LMK, Ljubljana, Slovenia
[7] Teknol Inst, Aarhus, Denmark
[8] Ctr Espanol Metrol, Madrid, Spain
[9] Slovak Inst Metrol, Bratislava, Slovakia
[10] Inst Portugues Qualidade, Caparica, Portugal
[11] Inst Natl Metrol, Bucharest, Romania
[12] Natl Phys Lab, Teddington, Middx, England
关键词
Al freezing point; Ag freezing point; CCT; EUROMET; fixed points; high-temperature standard platinum resistance thermometers; key comparison; Matthiessen's rule;
D O I
10.1007/s10765-007-0283-y
中图分类号
O414.1 [热力学];
学科分类号
摘要
The EUROMET.T-K4 comparison is the regional extension of CCT-K4, an intercomparison of the realizations of the freezing points of Al (660.323 degrees C) and Ag (961.78 degrees C). The intercomparison was organized in four loops. Long-stem standard platinum resistance thermometers (SPRTs) were used as traveling standards: 25 Omega thermometers to be used only at the Al freezing point and two high-temperature standard platinum resistance thermometers (HTSPRTs) to be used only at the Ag freezing point in each loop. Parallel to the measurements with thermometers, the pilots and sub-pilots organized an internal intercomparison using an Ag fixed-point cell. Most HTSPRTs showed a strong drift which is mainly due to mechanical stress and poisoning of the sensor by impurities. This drift can be partially compensated by a correction based on Matthiessen's rule. An evaluation of the data taking into account both HTSPRTs in each loop, the linkage of the sub-pilots by measurements at the Ag freezing point, and a possible compensation according to Matthiessens's rule, allows calculation of the results of the participants' measurements at the Ag freezing point. The results of the participating laboratories are summarized, and proposals for key comparison reference values and linking of the results to CCT-K3 and CCT-K4 are presented.
引用
收藏
页码:1964 / 1975
页数:12
相关论文
共 50 条
  • [1] Intercomparison of the Realization of the ITS-90 at the Freezing Points of Al and Ag among European NMIs
    D. Heyer
    U. Noatsch
    E. Tegeler
    M. Anagnostou
    E. Turzo-Andras
    I. Antonsen
    V. Augevicius
    J. Bojkovski
    A. Bronnum
    V. Chimenti
    S. Duris
    E. Filipe
    S. Gaita
    J. Gray
    D. Head
    E. Grudniewicz
    J. Ivarsson
    M. Kalemci
    O. Kerkhof
    I. Lobo
    S. Nemeth
    A. Pokhodun
    J. Ranostaj
    E. Renaot
    P. Rosenkranz
    M. Smid
    P. Steur
    A. Steiner
    M. Valin
    T. Veliki
    T. Weckström
    International Journal of Thermophysics, 2007, 28 : 1964 - 1975
  • [2] Intercomparison of the Realizations of the ITS-90 from 83.8058 K to 692.677 K among European NMIs
    E. Renaot
    Y. Hermier
    M. H. Valin
    G. Bonnier
    F. Adunka
    A. Van Der Linden
    M. Dobre
    M. Šmíd
    A. Bronnum
    T. Weckstrom
    E. Tegeler
    U. Noatsch
    M. Anagnostou
    E. Turzo-Andras
    S. Nemeth
    M. White
    P. Marcarino
    P. Steur
    A. Pauzha
    V. Augevicius
    M. de Groot
    J. Nielsen
    F. Helgesen
    W. Roszkowski
    E. Grudniewicz
    R. Kuna
    E. Filipe
    I. Lobo
    S. Gaita
    V. Chimenti
    J. Ivarsson
    S. Duris
    J. Ranostaj
    J. Bojkovski
    A. Steiner
    S. Ugur
    J. Gray
    S. Bruce
    R. Rusby
    D. Head
    International Journal of Thermophysics, 2008, 29 : 991 - 1000
  • [3] Intercomparison of the realizations of the ITS-90 from 83.8058 k to 692.677 k among european NMIs
    Renaot, E.
    Hermier, Y.
    Valin, M. H.
    Bonnier, G.
    Adunka, F.
    Van Der Linden, A.
    Dobre, M.
    Smid, M.
    Bronnum, A.
    Weckstrom, T.
    Tegeler, E.
    Noatsch, U.
    Anagnostou, M.
    Turzo-Andras, E.
    Nemeth, S.
    White, M.
    Marcarino, P.
    Steur, P.
    Pauzha, A.
    Augevicius, V.
    de Groot, M.
    Nielsen, J.
    Helgesen, F.
    Roszkowski, W.
    Grudniewicz, E.
    Kuna, R.
    Filipe, E.
    Lobo, I.
    Gaita, S.
    Chimenti, V.
    Ivarsson, J.
    Duris, S.
    Ranostaj, J.
    Bojkovski, J.
    Steiner, A.
    Ugur, S.
    Gray, J.
    Bruce, S.
    Rusby, R.
    Head, D.
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2008, 29 (03) : 991 - 1000
  • [4] ON THE DEFINITION OF FREEZING POINTS IN THE ITS-90
    ALEXANDROV, YI
    IVANOVA, AG
    POKHODUN, AI
    METROLOGIA, 1993, 30 (01) : 49 - 52
  • [5] A study on ITS-90 type 3 non-uniqueness between freezing points of Al and Ag
    Coppa, Graziano
    Merlone, Andrea
    MEASUREMENT, 2016, 89 : 109 - 113
  • [6] Methods for the Realization of its-90 Fixed Points: Necessity of Improvement
    A. G. Ivanova
    S. F. Gerasimov
    A. I. Pokhodun
    V. М. Fuksov
    Measurement Techniques, 2021, 64 : 573 - 579
  • [7] Methods for the Realization of its-90 Fixed Points: Necessity of Improvement
    Ivanova, A. G.
    Gerasimov, S. F.
    Pokhodun, A., I
    Fuksov, V. M.
    MEASUREMENT TECHNIQUES, 2021, 64 (07) : 573 - 579
  • [8] Realization of ITS-90 in Lithuania
    Pauza, A
    Galdikas, A
    Mikalauskas, K
    Augevicius, V
    Stankevicius, R
    TEMPMEKO 2001: 8TH INTERNATIONAL SYMPOSIUM ON TEMPERATURE AND THERMAL MEASUREMENT IN INDUSTRY AND SCIENCE, VOL 1 & 2, PROCEEDINGS, 2002, : 565 - 570
  • [9] Determination of the uncertainties for ITS-90 realization by SPRTs between fixed points
    Meyer, C. W.
    Ripple, D. C.
    METROLOGIA, 2006, 43 (05) : 327 - 340
  • [10] CRITICAL VIEWPOINTS ON THE METHODS OF REALIZING THE METAL FREEZING POINTS OF THE ITS-90
    MA, CK
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (08): : 4233 - 4240