Impact of Suture Techniques for Aortic Valve Replacement on Prosthesis-Patient Mismatch

被引:19
|
作者
Kim, Hyo-Hyun [1 ]
Lee, Sak [1 ]
Joo, Hyun-Chel [1 ]
Kim, Jung-Hwan [1 ]
Youn, Young-Nam [1 ]
Yoo, Kyung-Jong [1 ]
Lee, Seung-Hyun [1 ]
机构
[1] Yonsei Univ, Yonsei Univ Hlth Syst, Severance Cardiovasc Hosp, Div Cardiovasc Surg,Coll Med, 250 Seongsanno, Seoul 03722, South Korea
来源
ANNALS OF THORACIC SURGERY | 2020年 / 109卷 / 03期
关键词
HEMODYNAMIC PERFORMANCE; MORTALITY;
D O I
10.1016/j.athoracsur.2019.09.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Many variables may affect the hemodynamic performance of the aortic valve prosthesis, and suture technique remains an important factor for determining maximum valve performance. The objective of this study was to determine the suture technique that produces better hemodynamic performance for aortic valve replacement (AVR). Methods. Patients who underwent AVR between January 2015 and September 2018 in our institution were analyzed. We compared the preoperative clinical information and 1-year postoperative hemodynamic data of interrupted pledget mattress sutures (pledgeted group), interrupted nonpledget mattress sutures (nonpledgeted group), and figure-of-8 nonpledget sutures (figure-of-eight group). We compared the incidence of prosthesis-patient mismatch (PPM) and cardiac adverse events among the groups and subanalyzed the PPM rate in a small aortic annulus (18 to 21 mm). Results. A total of 439 patients underwent AVR (pledgeted, n = 212; nonpledgeted, n = 122; figure-of-eight, n = 105). The groups were similar in age (P = .359), sex (P = .055), underlying disease, and valve pathology. There was no difference in inhospital mortality or cardiac adverse events in each suture group (P = .282). The nonpledgeted suture had significantly lower moderate (P < .01) and severe PPM rates (P = .01) in patients with a small aortic annulus (18 to 21 mm). Conclusions. The interrupted nonpledget mattress suture offers complete supraannular implantation, which reduces the incidence of PPM and results in better hemodynamic improvement after small-size AVR. (C) 2020 by The Society of Thoracic Surgeons
引用
收藏
页码:661 / 667
页数:7
相关论文
共 50 条
  • [41] Prosthesis-Patient Mismatch After "High-Risk" Aortic Valve Replacement
    Popma, Jeffrey J.
    Khabbaz, Kamal
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (13) : 1335 - 1338
  • [42] The Incidence and Consequence of Prosthesis-Patient Mismatch After Surgical Aortic Valve Replacement
    Fallon, John M.
    DeSimone, Joseph P.
    Brennan, J. Matthew
    O'Brien, Sean
    Thibault, Dylan P.
    DiScipio, Anthony W.
    Pibarot, Philippe
    Jacobs, Jeffrey P.
    Malenka, David J.
    Clarizia, Nadia A.
    Ruel, Marc
    ANNALS OF THORACIC SURGERY, 2018, 106 (01): : 14 - 23
  • [43] Prosthesis-Patient Mismatch Following Aortic Valve Replacement: Finding Predictors for Prevention
    Tarasoutchi, Flavio
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2020, 114 (01) : 23 - 24
  • [44] Impact of Prosthesis Size and Prosthesis-Patient Mismatch on Outcomes in Younger Female Patients Undergoing Aortic Valve Replacement
    Kolkailah, Ahmed A.
    Hirji, Sameer A.
    Ejiofor, Julius I.
    Del Val, Fernando Ramirez
    Chowdhury, Ritam
    McGurk, Siobhan
    Lee, Jiyae
    Kaneko, Tsuyoshi
    SEMINARS IN THORACIC AND CARDIOVASCULAR SURGERY, 2020, 32 (02) : 219 - 228
  • [45] Imaging for Predicting and Assessing Prosthesis-Patient Mismatch After Aortic Valve Replacement
    Pibarot, Philippe
    Magne, Julien
    Leipsic, Jonathon
    Cote, Nancy
    Blanke, Philippe
    Thourani, Vinod H.
    Hahn, Rebecca
    JACC-CARDIOVASCULAR IMAGING, 2019, 12 (01) : 149 - 162
  • [46] Prosthesis-Patient Mismatch after Aortic Valve Replacement with the Mosaic Ultra Bioprosthesis
    Ntinopoulos, Vasileios
    Biefer, Hector Rodriguez Cetina
    Dushaj, Stak
    Rings, Laura
    Fleckenstein, Philine
    Dzemali, Omer
    Haeussler, Achim
    THORACIC AND CARDIOVASCULAR SURGEON, 2024, 72 (03): : 197 - 204
  • [47] Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement
    Freeman, Melanie
    Webb, John G.
    Willson, Alexander B.
    Wheeler, Miriam
    Blanke, Philipp
    Moss, Robert R.
    Thompson, Christopher R.
    Munt, Brad
    Norgaard, Bjarne L.
    Yang, Tae-Hyun
    Min, James K.
    Poulsen, Steen
    Hansson, Nicolaj C.
    Binder, Ronald K.
    Toggweiler, Stefan
    Hague, Cameron
    Wood, David A.
    Pibarot, Philippe
    Leipsic, Jonathon
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2013, 7 (04) : 248 - 255
  • [48] Aortic valve replacement and prosthesis-patient mismatch in the era of trans-catheter aortic valve implantation
    Morita, Shigeki
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2016, 64 (08) : 435 - 440
  • [49] Aortic valve replacement and prosthesis-patient mismatch in the era of trans-catheter aortic valve implantation
    Shigeki Morita
    General Thoracic and Cardiovascular Surgery, 2016, 64 : 435 - 440
  • [50] Suture Techniques and Patient-Prosthesis Mismatch for Aortic Valve Surgery
    Iscan, Sahin
    Eygi, Bortecin
    Yesilkaya, Nihan
    ANNALS OF THORACIC SURGERY, 2020, 110 (05): : 1781 - 1781