Impact of Suture Techniques for Aortic Valve Replacement on Prosthesis-Patient Mismatch

被引:19
|
作者
Kim, Hyo-Hyun [1 ]
Lee, Sak [1 ]
Joo, Hyun-Chel [1 ]
Kim, Jung-Hwan [1 ]
Youn, Young-Nam [1 ]
Yoo, Kyung-Jong [1 ]
Lee, Seung-Hyun [1 ]
机构
[1] Yonsei Univ, Yonsei Univ Hlth Syst, Severance Cardiovasc Hosp, Div Cardiovasc Surg,Coll Med, 250 Seongsanno, Seoul 03722, South Korea
来源
ANNALS OF THORACIC SURGERY | 2020年 / 109卷 / 03期
关键词
HEMODYNAMIC PERFORMANCE; MORTALITY;
D O I
10.1016/j.athoracsur.2019.09.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Many variables may affect the hemodynamic performance of the aortic valve prosthesis, and suture technique remains an important factor for determining maximum valve performance. The objective of this study was to determine the suture technique that produces better hemodynamic performance for aortic valve replacement (AVR). Methods. Patients who underwent AVR between January 2015 and September 2018 in our institution were analyzed. We compared the preoperative clinical information and 1-year postoperative hemodynamic data of interrupted pledget mattress sutures (pledgeted group), interrupted nonpledget mattress sutures (nonpledgeted group), and figure-of-8 nonpledget sutures (figure-of-eight group). We compared the incidence of prosthesis-patient mismatch (PPM) and cardiac adverse events among the groups and subanalyzed the PPM rate in a small aortic annulus (18 to 21 mm). Results. A total of 439 patients underwent AVR (pledgeted, n = 212; nonpledgeted, n = 122; figure-of-eight, n = 105). The groups were similar in age (P = .359), sex (P = .055), underlying disease, and valve pathology. There was no difference in inhospital mortality or cardiac adverse events in each suture group (P = .282). The nonpledgeted suture had significantly lower moderate (P < .01) and severe PPM rates (P = .01) in patients with a small aortic annulus (18 to 21 mm). Conclusions. The interrupted nonpledget mattress suture offers complete supraannular implantation, which reduces the incidence of PPM and results in better hemodynamic improvement after small-size AVR. (C) 2020 by The Society of Thoracic Surgeons
引用
收藏
页码:661 / 667
页数:7
相关论文
共 50 条
  • [1] Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Sa, Michel Pompeu
    Jacquemyn, Xander
    Van den Eynde, Jef
    Tasoudis, Panagiotis
    Dokollari, Aleksander
    Torregrossa, Gianluca
    Sicouri, Serge
    Clavel, Marie-Annick
    Pibarot, Philippe
    Ramlawi, Basel
    JACC-CARDIOVASCULAR IMAGING, 2022, 16 (03) : 298 - 310
  • [2] Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Levesque, Thomas
    Eltchaninoff, Helene
    Chabannes, Romain
    Barbe, Thomas
    Dosseh, Olivier
    Tron, Christophe
    Bettinger, Nicolas
    Bouhzam, Najime
    Hemery, Thibaut
    le Pessec, Guillaume
    Fauvel, Charles
    Cribier, Alain
    Pibarot, Philippe
    Durand, Eric
    CANADIAN JOURNAL OF CARDIOLOGY, 2024, 40 (01) : 113 - 122
  • [3] Prosthesis-patient mismatch after aortic valve replacement
    Dahou A.
    Mahjoub H.
    Pibarot P.
    Current Treatment Options in Cardiovascular Medicine, 2016, 18 (11)
  • [4] Figure of eight suture technique in aortic valve replacement decreases prosthesis-patient mismatch
    Rasheed, Nabeel F.
    Stonebraker, Corinne
    Li, Zhaozhi
    Siddiqi, Umar
    Lee, Andy C. H.
    Li, Willa
    Lupo, Sydney
    Cruz, Jennifer
    Cohen, William G.
    Staub, Cathy
    Rodgers, Daniel
    Myren, Mark
    Combs, Pamela
    Jeevanandam, Valluvan
    Hibino, Narutoshi
    JOURNAL OF CARDIOTHORACIC SURGERY, 2023, 18 (01)
  • [5] Figure of eight suture technique in aortic valve replacement decreases prosthesis-patient mismatch
    Nabeel F. Rasheed
    Corinne Stonebraker
    Zhaozhi Li
    Umar Siddiqi
    Andy C. H. Lee
    Willa Li
    Sydney Lupo
    Jennifer Cruz
    William G. Cohen
    Cathy Staub
    Daniel Rodgers
    Mark Myren
    Pamela Combs
    Valluvan Jeevanandam
    Narutoshi Hibino
    Journal of Cardiothoracic Surgery, 18
  • [6] Impact of prosthesis-patient mismatch on mitral regurgitation after aortic valve replacement
    Unger, P.
    Magne, J.
    Eynden, F. Vanden
    Plein, D.
    Van Camp, G.
    Pasquet, A.
    Cosyns, B.
    Dedobbeleer, C.
    Lancellotti, P.
    HEART, 2010, 96 (20) : 1627 - 1632
  • [7] Overcoming prosthesis-patient mismatch with transcatheter aortic valve replacement
    Grubb, Kendra J.
    Tom, Stephanie K.
    Sultan, Ibrahim
    Sa, Michel Pompeu
    ANNALS OF CARDIOTHORACIC SURGERY, 2024, 13 (03) : 236 - 243
  • [8] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Herrmann, Howard C.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (21) : 2183 - 2185
  • [9] Prosthesis-Patient Mismatch in the Transcatheter Aortic Valve Replacement Era
    Tuzcu, E. Murat
    Oezkan, Alper
    Kapadia, Samir R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) : 1919 - 1922
  • [10] The relevance of prosthesis-patient mismatch after aortic valve replacement
    Pibarot, Philippe
    Dumesnil, Jean G.
    NATURE CLINICAL PRACTICE CARDIOVASCULAR MEDICINE, 2008, 5 (12): : 764 - 765