Effectiveness of the Baska mask versus the i-gel device in adult patients under general anesthesia: a systematic review protocol

被引:0
|
作者
Han, Qiaoyu [1 ]
Sun, Liang [1 ]
Liang, Hansheng [1 ]
Feng, Yi [1 ]
机构
[1] Peking Univ Peoples Hosp, Dept Anesthesiol, Beijing, Peoples R China
关键词
airway management; anesthesia; general; Baska mask; i-gel; supraglottic airway devices; SUPRAGLOTTIC AIRWAY DEVICES; LMA SUPREME; METAANALYSIS; PERFORMANCE; I-GEL(TM);
D O I
10.11124/JBIES-20-00045
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Objective: The objective of this review is to evaluate the ease of use, effectiveness of airway management, and incidence of perioperative complications of the Baska mask compared to the i-gel device in adult patients undergoing elective procedures with general anesthesia. Introduction: Supraglottic airway devices have been widely used for airway management in patients undergoing various surgical procedures under general anesthesia. The Baska mask and the i-gel device are two commonly used second-generation supraglottic airway devices that offer a noninvasive alternative to the endotracheal tube given the ease of insertion, rapidity, low risk of postoperative complications, and reduced autonomic imbalance during insertion. However, there is a dearth of studies comparing the clinical performance of these two devices. Inclusion criteria: This review will consider studies with adults aged 18 years or older who underwent elective surgical procedures under general anesthesia and received ventilation with the Baska mask or i-gel. Only randomized controlled trials comparing the two devices will be considered. Methods: MEDLINE, Embase, the Cochrane Library, Web of Science, ClinicalTrials.gov, OpenGrey, and ProQuest Dissertations and Theses will be searched to identify both published and unpublished studies. Titles and abstracts will be screened to identify potentially relevant papers. Retrieval of full-text studies, assessment of methodological quality, and data extraction will be performed independently by two reviewers. Data will be synthesized using statistical meta-analysis with heterogeneity of data being assessed using the standard chi-squared and I (2) tests, if possible. Systematic review registration number: PROSPERO CRD42020168774.
引用
收藏
页码:2673 / 2679
页数:7
相关论文
共 50 条
  • [31] A randomized controlled study to compare oropharyngeal leak pressure between I-gel™ and laryngeal mask airway supreme™ in children in lateral position under general anesthesia
    Raksha Kundal
    Kriti Puri
    Garima Agrawal
    Ranju Singh
    Maitree Pandey
    Ain-Shams Journal of Anesthesiology, 15
  • [32] MEDICATION ERRORS IN PATIENTS UNDER GENERAL ANESTHESIA: A SYSTEMATIC REVIEW
    Abrishami, Amir
    Correa, Jeff
    Abrahamyan, Lusine
    Wong, Jean
    Nanji, Karen
    Orser, Beverley A.
    Chung, Frances F.
    ANESTHESIA AND ANALGESIA, 2018, 126 (04): : 486 - 486
  • [33] Comparing Ambu AuraGain TM Disposable Laryngeal Mask with i-gel TM as a conduit for fibreoptic guided tracheal intubation for elective surgery under general anaesthesia in adult patients
    Raj, Deepak
    Bathla, Sapna
    Krishna, Bhavya
    Wason, Rama
    Girdhar, K. K.
    TRENDS IN ANAESTHESIA AND CRITICAL CARE, 2024, 55
  • [34] The comparison of ProSeal and I-gel laryngeal mask airways in anesthetized adult patients under controlled ventilation (vol 36, pg 432, 2015)
    Ekinci, Osman
    Abitagaoglu, Suheyla
    Turan, Guldem
    SAUDI MEDICAL JOURNAL, 2015, 36 (07) : 885 - 885
  • [35] Comparison of the clinical performances of Air-Qsp and i-Gel for airway management under general anesthesia with a muscle relaxant
    Watanabe, Asako
    Edanaga, Mitsutaka
    Ichinose, Hiromichi
    Yamakage, Michiaki
    JOURNAL OF CLINICAL ANESTHESIA, 2016, 34 : 223 - 226
  • [36] I-GEL LARYNGEAL MASK AIRWAY: AN EFFECTIVE SUPRAGLOTTIC AIRWAY FOR SPONTANEOUS BREATHING GENERAL ANESTHESIA IN NON-INTUBATED UNIPORTAL THORACOSCOPIC RESECTION
    Jiang, Shan
    Yin, Fei
    Wang, Mei-qing
    Cui, Yan
    Sun, Yang
    ACTA MEDICA MEDITERRANEA, 2019, 35 (06): : 3127 - 3130
  • [37] Comparison of the i-gel and other supraglottic airways in adult manikin studies Systematic review and meta-analysis
    An, Jiwon
    Nam, Sang Beom
    Lee, Jong Seok
    Lee, Jinae
    Yoo, Hanna
    Lee, Hye Mi
    Kim, Min-Soo
    MEDICINE, 2017, 96 (01)
  • [38] Laparoscopic Sterilization Under Local Anesthesia with Conscious Sedation Versus General Anesthesia: Systematic Review of the Literature
    Huppelschoten, Aleida G.
    Bijleveld, Kim
    Braams, Loes
    Schoot, Benedictus C.
    van Vliet, Huib A. A. M.
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2018, 25 (03) : 393 - 401
  • [39] A comparative evaluation of ProSeal laryngeal mask airway, I-gel and Supreme laryngeal mask airway in adult patients undergoing elective surgery: A randomised trial
    Singh, Anisha
    Bhalotra, Anju R.
    Anand, Raktima
    INDIAN JOURNAL OF ANAESTHESIA, 2018, 62 (11) : 858 - 864
  • [40] Comparison of Outcome of Laryngeal Mask Airway (LMA Classic) and I-Gel Devices in Patients Undergoing General Anaesthesia in Elective Surgeries
    Dar, Shahid Rasool
    Hussain, Riaz
    Nazeer, Tahir
    Tahir, Amna
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2015, 9 (03): : 1036 - 1038